1、BSI Standards PublicationBS EN 3660-065:2016Aerospace series Cableoutlet accessories for circularand rectangular electrical andoptical connectorsPart 065 : Cable outlet, style K, 90, forheat shrinkable boot, shielded, sealed, selflocking Product standardBS EN 3660-065:2016 BRITISH STANDARDNational f
2、orewordThis British Standard is the UK implementation of EN 3660-065:2016. It supersedes BS EN 3660-065:2009 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology.A list of organizations represen
3、ted on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 8
4、9596 8 ICS 49.060 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN
5、 3660-065:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 3660-065 January 2016 ICS 49.060 Supersedes EN 3660-065:2009English Version Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 065 : Cable outlet, style K, 90, for heat s
6、hrinkable boot, shielded, sealed, self locking - Product standard Srie arospatiale - Accessoires arrire pour connecteurs circulaires et rectangulaires lectriques et optiques - Partie 065 : Raccord type K, coud 90, blind, tanche, pour manchon thermortractable, auto-frein pour EN 2997 - Norme de produ
7、it Luft- und Raumfahrt - Endgehuse fr elektrische und optische Rund- und Rechtecksteckverbinder - Teil 065: Endgehuse, Bauform K, 90, fr wrmeschrumpfende Bauteile, Schirmanschluss, abgedichtet, selbstsichernd - Produktnorm This European Standard was approved by CEN on 8 June 2015. CEN members are bo
8、und to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the
9、CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre
10、 has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
11、 Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000
12、Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 3660-065:2016 EBS EN 3660-065:2016EN 3660-065:2016 (E) 2 Contents Page European foreword 3 1 Scope 4 2 Normative references 5 3 Terms and definitions . 5 4 Characteristi
13、cs . 5 5 Tests . 12 6 Designation . 19 7 Marking . 19 8 Technical specification . 19 BS EN 3660-065:2016EN 3660-065:2016 (E) 3 European foreword This document (EN 3660-065:2016) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquir
14、ies and votes carried out in accordance with the rules of this Association, this European Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a
15、national standard, either by publication of an identical text or by endorsement, at the latest by July 2016, and conflicting national standards shall be withdrawn at the latest by July 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
16、 rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 3660-065:2009. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European
17、Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia
18、, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 3660-065:2016EN 3660-065:2016 (E) 4 1 Scope This European Standard defines a range of cable outlets, style K, 90, shielded, sealed, self-locking (anti-rotational) for heat shrinkable boot, and or with metallic bands under the followi
19、ng conditions. The mating connectors are listed in EN 3660-002. NOTE Class N in EN 3660-001 cross refers to class F in EN 3660-065. Temperature range, Class F (N) : 65 C to 200 C (See note above); Class K : 65 C to 200 C; Class KE : 65 C to 260 C; Class W : 65 C to 175 C; Class T : 65 C to 175 C (Ni
20、ckel PTFE plating); Class Z : 65 C to 175 C (Zinc Nickel plating). Associated electrical accessories : EN 3660-033 Metallic band (for shield termination). These cable outlets are designed for termination of overall shielding braid and / or individual cable shields. They accommodate/permit the termin
21、ation of heat shrinkable boots. BS EN 3660-065:2016EN 3660-065:2016 (E) 5 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated refe
22、rences, the latest edition of the referenced document (including any amendments) applies. EN 2591- 1), Aerospace series Elements of electrical and optical connection Test methods EN 2997 (all parts), Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non f
23、ire-resistant, operating temperatures 65 C to 175 C continuous, 200 C continuous, 260 C peak EN 3660-001, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 001: Technical specification EN 3660-002, Aerospace series Cable outlet accessories
24、for circular and rectangular electrical and optical connectors Part 002: Index of product standards EN 3660-033, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 033: Stainless steel banding band, style Z, for attachment of individual and/
25、or overall screens to cable outlets Product standard 2)AS85049A, Connector accessories, electrical general specification for- 3)IEC 60529, Degrees of protection provided by enclosures (IP Code) DIN 82, Knurling 3 Terms and definitions For the purposes of this document, the terms and definitions give
26、n in EN 3660-001 apply. (Self-locking / anti rotational definition) A self-locking or anti rotational mechanism provides a nut rotation with moderate torque in the mated direction and provides a greater torque in the unmated direction. 4 Characteristics 4.1 Dimensions and mass For dimensions and mas
27、s, see Figure 1 and Table 1 to Table 4. For cable entry dimensions, see 4.2. All dimensions are in millimetres. 1) All its parts quoted in this European Standard. 2) In preparation at the date of publication of this European Standard. 3) Published by: SAE National (US) Society of Automotive Engineer
28、s http:/www.sae.org/BS EN 3660-065:2016EN 3660-065:2016 (E) 6 Key 1 Thread C 2 Marking 3 Number of teeth N 4 Four tooling holes spaced 90 apart. 2,60, depth ,1,27 5 Straight knurl. Pitch manufacturers option. 6 RKV 08 DIN 82. Figure 2. (Please note there may be crossover dependent on diameter and pi
29、tch) 7 Clearance on thread C 8 Break edge NOTE 1 Cable outlets may be manufactured as cast, fabricated or machined (manufactures option) NOTE 2 No sharp edges / burrs permissible on internal or external surfaces / joints. Surface finish of on all internal surfaces NOTE 3 Valley of start of tooth to
30、be at vertical centre line of accessory at position shown: within 3 for shell sizes 08-12; within 2 for shell sizes 14-18; within 1 for shell sizes 20 and larger. Figure 1 1,6 m max. BS EN 3660-065:2016EN 3660-065:2016 (E) 7 Table 1 Fixed dimensions of shell Dimensions in millimetres Shell size A B
31、C E G H J max. max. Thread max. max. max. max. 08 22,48 15,67 0,500-20UNF 15,3 16,1 10,2 31,05 10 25,65 18,64 0,625-24UNEF 15,3 17,9 13,7 34,21 12 28,83 21,79 0,750-20UNEF 15,3 19,4 16,8 37,95 14 32,00 24,99 0,875-20UNEF 15,3 20,0 17,9 39,65 16 35,18 28,24 1,000-20UNEF 15,3 21,6 21,2 41,25 18 38,55
32、30,94 1,062-18UNEF 15,3 22,6 23,2 43,75 20 41,53 34,16 1,188-18UNEF 15,3 24,1 26,2 46,91 22 44,70 37,29 1,312-18UNEF 15,3 25,7 29,4 50,10 24 47,89 40,46 1,438-18UNEF 15,3 27,4 32,6 53,29 28 54,23 49,45 1,750-18UNS 15,3 30,9 39,6 56,46 Table 2 Mass for classes F (N), T, W, Z, K and KE Nominal mass in
33、 grams Shell size code End-fitting size code Length code wiring chamber A B C D E F G H J K L M 08 13,3 13,6 F (N), T, W, Z 33,8 34,4 K and KE 10 15,9 16,5 17,2 17,9 F (N), T, W, Z 40,0 41,9 43,6 45,5 K and KE 12 19,4 19,8 20,2 21,1 21,7 22,2 F (N), T, W, Z 48,8 49,9 51,0 53,3 54,8 56,2 K and KE 14
34、23,9 24,3 24,7 25,1 25,9 26,5 27,7 F (N), T, W, Z 58,8 59,9 61,0 62,0 64,3 66,0 69,1 K and KE 16 28,1 28,6 29,0 29,3 29,6 29,9 31,7 32,7 F (N), T, W, Z 69,5 70,6 71,7 72,6 73,3 74,1 78,9 81,7 K and KE 18 30,9 31,3 31,7 32,0 32,3 32,6 33,7 35,3 F (N), T, W, Z 77,5 78,6 79,7 80,6 81,3 82,1 85,2 89,2 K
35、 and KE BS EN 3660-065:2016EN 3660-065:2016 (E) 8 Shell size code End-fitting size code Length code wiring chamber A B C D E F G H J K L M 20 38,0 38,4 38,8 39,1 39,4 39,7 40,3 41,7 42,7 F (N), T, W, Z 94,1 95,3 96,3 97,3 98,0 98,8 100,3 104,1 106,6 K and KE 22 41,9 42,3 42,7 43,1 43,3 43,7 44,2 44,
36、6 45,8 47,0 F (N), T, W, Z 104,9 106,0 107,1 108,0 108,7 109,6 111,1 112,1 115,2 118,2 K and KE 24 51,1 51,5 51,9 52,3 52,6 52,9 53,5 53,8 54,6 55,2 56,6 F (N), T, W, Z 125,8 126,9 128,0 129,0 129,6 130,5 132,0 133,0 135,0 136,5 140,3 K and KE 28 67,8 68,2 68,6 69,0 69,3 69,6 70,2 70,5 71,3 71,9 72,
37、5 73,9 F (N), T, W, Z 168,8 169,9 171,0 172,0 172,6 173,5 175,0 176,0 178,0 179,5 180,3 183,3 K and KE 4.2 Cable entry dimensions See Figure 2, Table 4. NOTE No burrs or sharp edges permitted Figure 2 Cable entry BS EN 3660-065:2016EN 3660-065:2016 (E) 9 Table 3 Dimensions in millimetres Cable entry
38、 size code A B C D min. Bundle/ Cable diameter 0,1 0,1 0,3 + 0,2 0 min. max. A 4,7 7,7 12,2 1,12 2,0 4,0 B 6,4 9,4 14,0 1,12 3,9 5,5 C 7,9 11,0 15,5 1,12 5,4 7,5 D 9,5 12,6 17,1 1,12 7,4 9,0 E 11,1 14,1 18,7 1,12 9,4 10,5 F 12,7 15,7 20,3 1,12 10,4 12,0 G 15,9 18,9 23,5 1,12 12,4 15,5 H 19,1 22,0 26
39、,7 1,12 15,4 18,5 J 22,2 25,2 29,8 1,75 18,4 21,5 K 25,5 28,4 33,0 1,75 21,4 25,0 L 28,6 31,5 36,2 1,75 25,4 28,0 M 31,8 34,7 39,4 1,75 28,4 31,0 NOTE The cable outlet shall be selected in accordance with the diameter of the cable bundle. 4.3 Associated connectors See EN 3660-002. BS EN 3660-065:201
40、6EN 3660-065:2016 (E) 10 4.4 Front interface 4.4.1 AS85049 interface all classes See Figure 3, Figure 4 and Table 4. All dimensions are in millimetres. Key 1 4,95 min. penetration of J from front of serrations Figure 3 Detail X Figure 4 Detail Y Table 4 Dimensions in millimetres Shell size G H J N 0
41、 0,38 + 0,38 0 0 0,25 Number of teeth 08 9,14 7,59 6,86 12 10 12,55 11,00 9,53 15 12 15,49 13,94 12,98 21 14 18,67 17,12 14,86 24 16 21,84 20,29 18,03 30 18 23,27 22,07 20,04 33 20 26,44 25,25 23,22 36 22 29,62 28,42 26,39 39 24 32,79 31,60 29,31 42 28 38,40 37,31 35,28 54 BS EN 3660-065:2016EN 3660
42、-065:2016 (E) 11 4.4.2 Optional AS85049 interface, classes K and KE (Stainless steel) only See Figure 5, Figure 6 and Table 5. Key 1 4,95 min. penetration of L from front of serrations Figure 5 Detail X Figure 6 Detail Y Table 5 Dimensions in millimetres Shell size G H J L M N Ref. 0,13 + 0,18 0 0 0
43、,25 0,13 Number of teeth 08 11,10 9,17 6,68 N/A N/A 12 10 14,53 11,10 9,35 N/A N/A 15 12 17,45 14,83 12,62 N/A N/A 21 14 20,62 17,22 15,98 14,86 4,44 24 16 23,80 20,55 17,73 N/A N/A 30 18 25,20 22,48 21,46 20,04 4,34 33 20 28,37 25,53 25,02 23,22 4,24 36 22 31,55 29,01 27,61 26,39 4,42 39 24 34,72 3
44、2,46 31,62 29,31 4,09 42 28 42,75 38,91 37,97 35,28 3,99 54 BS EN 3660-065:2016EN 3660-065:2016 (E) 12 4.5 Material and finish NOTE Class N in EN 3660-001 cross refers to class F in EN 3660-065. Material/Finish Class F (N) : Aluminium/Nickel plated (see note above) Material/Finish Class K : Stainles
45、s steel (Passivated) Material/Finish Class KE : Stainless steel (Passivated) Material/Finish Class W : Aluminium/Olive drab cadmium plated Material Finish Class T : Aluminium (Nickel PTFE plated) Material/ Finish Class Z : Aluminium (Zinc Nickel plated) 4.6 Assembly torque These torque values are in
46、tended for installation use only, see Table 6. Table 6 Shell size Assembly torque 0,56 Nm Classes K and KE Classes F (N), T, W, Z 08 6,33 4,52 10 8,59 4,52 12 12,20 4,52 14 13,11 4,52 16 13,11 4,52 18 13,11 4,52 20 15,37 9,04 22 15,37 9,04 24 15,37 9,04 28 16,72 13,56 5 Tests 5.1 Tests according to
47、EN 2591-100 Test details to be in accordance with Table 7, EN 3660-001 and EN 2591-100. Qualification to be in accordance with EN 3660-001. BS EN 3660-065:2016EN 3660-065:2016 (E) 13 Table 7 EN 2591- Designation of the test Not applicable Applicable see EN 3660-001 Details 101 Visual examination X 1
48、02 Examination of dimensions and mass X See 4.1 and 4.2. 205 Housing (shell) electrical continuity X Cable outlet connector connection. Class F (N): 2,5 m Class W: 5 m Class K: 10 m Class KE: 10 m Class T: 5 m Class Z: 5 m 212 Surface transfer impedance (from 100 MHz to 1 GHz) aX Frequency Zt (m) MHz Class F (N) Classes W, T, Z Classes K and KE 0,1 5 10 20 1 5 10 20 10 7 15 30 30 10 20 40 100 20 40 80 Test mounting as per 5.2 and Figure 7. The Zt values correspond to the total surface impedance of the assembly. Test shall be achieved with t