EN 50107-2-2005 en Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Part 2 Requirements for eart.pdf

上传人:brainfellow396 文档编号:716658 上传时间:2019-01-04 格式:PDF 页数:24 大小:363.34KB
下载 相关 举报
EN 50107-2-2005 en Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Part 2 Requirements for eart.pdf_第1页
第1页 / 共24页
EN 50107-2-2005 en Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Part 2 Requirements for eart.pdf_第2页
第2页 / 共24页
EN 50107-2-2005 en Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Part 2 Requirements for eart.pdf_第3页
第3页 / 共24页
EN 50107-2-2005 en Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Part 2 Requirements for eart.pdf_第4页
第4页 / 共24页
EN 50107-2-2005 en Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Part 2 Requirements for eart.pdf_第5页
第5页 / 共24页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN 50107-2:2005 Signs and luminous-discharge- tube installations operating from a no-load rated output voltage exceeding 1 kV but not ex cee din g10kV Part 2: Requirements for earth-leakage and open-circuit protective devices The European Standard EN 50107-2:2005 has the status o

2、f a British Standard ICS 29.140.30 BS EN 50107-2:2005 This British Standard, was published under the authority of the Standards Policy and Strategy Committee on 29 April 2005 BSI 29 April 2005 ISBN 0 580 45944 6 National foreword This British Standard is the official English language version of EN 5

3、0107-2:2005. The UK participation in its preparation was entrusted by Technical Committee CPL/34, Lamps and related equipment, to Subcommittee CPL/34/11, Electric signs, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secret

4、ary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalog

5、ue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the

6、 text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front

7、 cover, an inside front cover, the EN title page, pages 2 to 20, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 50107-2 NORME EUROPE

8、NNE EUROPISCHE NORM April 2005 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any

9、form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50107-2:2005 E ICS 29.140.30 English version Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Part 2: Requirements for earth-leakage and open-

10、circuit protective devices Installation denseignes et de tubes lumineux dcharge fonctionnant une tension de sortie vide assigne suprieure 1 kV mais ne dpassant pas 10 kV Partie 2: Prescriptions pour les dispositifs de protection contre les dfauts disolement et contre louverture des circuits secondai

11、res Leuchtrhrengerte und Leuchtrhrenanlagen mit einer Leerlaufspannung ber 1 kV, aber nicht ber 10 kV Teil 2: Anforderungen an Erdschlussschutz- und Leerlaufschutzeinrichtungen This European Standard was approved by CENELEC on 2005-03-01. CENELEC members are bound to comply with the CEN/CENELEC Inte

12、rnal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC m

13、ember. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENE

14、LEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,

15、Switzerland and United Kingdom. EN 50107-2:2005 - 2 - Foreword This European Standard was prepared by CENELEC BTTF 60-2, Electrical discharge lamp installations. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50107-2 on 2005-03-01. The following dates were f

16、ixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2006-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-03-01 _ - 3 - EN 50107-2:2005 Contents Pag

17、e 1 Scope5 2 Normative references5 3 Definitions5 4 General requirements .6 5 Tests .6 6 Classification .7 7 Marking.7 7.1 Items of marking7 7.2 Durability of marking7 7.3 Additional information7 8 Terminals8 9 Provision for protective earthing.8 10 Protection against accidental contact with live pa

18、rts.8 11 Moisture resistance and insulation of type B devices8 12 Electric strength9 13 Thermal endurance of devices 9 13.1 General 9 13.2 Tests for type B devices 9 13.3 Tests for type A or type C devices.9 14 Fault conditions 10 15 Construction10 16 Creepage distances and clearances.10 17 Screws,

19、current-carrying parts and connections 10 18 Resistance to heat, fire and tracking 10 19 Resistance to corrosion .10 20 Performance 10 20.1 Performance requirements for earth-leakage protective devices10 20.2 Performance requirements for open-circuit protective devices .11 EN 50107-2:2005 - 4 - 20.3

20、 Performance requirements common to both types of device11 21 Interchangeability .12 Annex A (normative) - Testing of the response time of earth-leakage protective devices 13 Annex B (informative) - An example method of measuring the performance of an earth-leakage protective device15 Annex C (norma

21、tive) - Test of the response time of open-circuit protective devices 17 Annex D (informative) - A method of measuring the performance of an open-circuit protective device.19 Figure B.1 - Typical circuit to measure the performance of an earth-leakage protective device .14 Figure D.1 - Typical circuit

22、 to measure the performance of an open-circuit protective device 18 - 5 - EN 50107-2:2005 1 Scope This European Standard specifies requirements for earth-leakage and open-circuit protective devices designed to protect circuits for neon tubes operating from transformers conforming to EN 61050 at volt

23、ages exceeding 1 000 V but not exceeding 10 000 V. NOTE 1 Requirements for the installation of earth-leakage and open-circuit protective devices are given in EN 50107-1. NOTE 2 Requirements for earth-leakage and open-circuit protective devices used with inverters and converters are specified in EN 6

24、1347-2-10. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50107-1:2002

25、, Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV - Part 1: General requirements EN 60529:1991, Degrees of protection provided by enclosures (IP code) (IEC 60529:1989) EN 60598-1:2000, Luminaires - Part 1: General r

26、equirements and tests (IEC 60598-1:1999, mod.) EN 61050:1992, Transformers for tubular discharge lamps having a no-load output voltage exceeding 1 kV (generally called neon-transformers) - General and safety requirements (IEC 61050:1991 + corrigendum March 1992, mod.) EN 61347-1:2001, Lamp controlge

27、ar - Part 1: General and safety requirements (IEC 61347-1:2000) 3 Definitions For the purposes of this European Standard, the definitions given in EN 50107-1 and EN 61347-1 apply, together with the following. NOTE Where the terms “voltage” and “current” are used, they refer to r.m.s. values unless o

28、therwise stated. 3.1 type A device earth-leakage or open-circuit protective device generally designed to be built into the enclosure of a transformer and not intended to be mounted outside a transformer without special precautions NOTE A type A device normally protects only the transformer in which

29、it is mounted. 3.2 type B device earth-leakage or open-circuit protective device consisting of one or more separate elements so designed that it can be mounted outside a transformer and housed in an enclosure that provides all necessary protection according to its markings NOTE 1 The enclosure may c

30、onsist of the sign in which the device is mounted; the sign having a protection according to its markings. NOTE 2 The device may protect more than one transformer. EN 50107-2:2005 - 6 - 3.3 type C device earth-leakage or open-circuit protective device that forms a non-replaceable part of a transform

31、er and which normally cannot be tested separately from the transformer 3.4 earth-leakage current fault current flowing from a point in the output circuit to earth 3.5 open-circuit condition discnnection or lamp fault in the output circuit that causes the secondary load current of the transformer fee

32、ding the lamp circuit to fall below the respective shut-down current limit 3.6 shut-down current limit secondary load current of a transformer at which an open-circuit protective device operates NOTE Although the shut-down current limit is specified in terms of the current flowing in the output circ

33、uit, the manufacturer of the device may measure this by other than direct means. Such means might include, e.g. measuring the current reflected into the primary winding of the transformer or measuring a change in circuit power factor. 3.7 sensor device that detects an earth-leakage current or, in th

34、e case of an open-circuit protective device, detects when the secondary load current has fallen below the shut-down current limit, and either causes a protective switch to operate or otherwise causes the output voltage of a transformer to be removed 3.8 protective switch part of an earth-leakage or

35、open-circuit protective device that disconnects the mains supply from a transformer 3.9 response time time from the start of the fault condition until the protective device removes the output voltage 3.10 secondary load current current flowing in the output circuit of transformer supplying one or mo

36、re tubes 4 General requirements EN 61347-1:2001, Clause 4, shall apply, with the words “earth-leakage protective device” or “open- circuit protective device” (as appropriate) substituted for “lamp controlgear”. 5 Tests 5.1 With the exception of EN 61347-1:2001, Subclause 5.4 (see 5.2), EN 61347-1:20

37、01, Clause 5, shall apply, with the words “earth-leakage protective device” or “open-circuit protective device” (as appropriate) substituted for “lamp controlgear”. - 7 - EN 50107-2:2005 5. 2 The requirements of EN 61347-1:2001, Subclause 5.4, shall be replaced by the following: a) a total of ten de

38、vices shall be selected at random for the tests; b) type A devices shall be tested with a representative sample of the associated transformer in which the device is normally mounted; c) type B devices shall be tested with transformers having characteristics at either end of the range specified in ac

39、cordance with 7.3 h); d) type C devices shall be tested complete with their associated transformers; e) three devices, taken at random from the batch of ten, shall be tested in accordance with the relevant tests specified in this European Standard. The results shall be assessed as follows: 1) if all

40、 three samples pass all the tests, the batch shall be deemed to conform to this European Standard; 2) if two or more samples fail any of the tests, the batch shall be deemed not to conform to this European Standard; 3) if one sample fails any of the tests, the tests shall be repeated on a second bat

41、ch of three devices; 4) if all three devices from this second batch pass all the tests, the batch shall be deemed to conform to this European Standard; 5) if any device from this second batch fails any of the tests, the entire batch shall be deemed not to conform to this European Standard. 6 Classif

42、ication EN 61347-1:2001, Clause 6 shall apply, with the words “earth-leakage protective device” or “open- circuit protective device” (as appropriate) substituted for “lamp controlgear”. 7 Marking 7.1 Items of marking The following items shall be marked, either: a) on the device itself, in the case o

43、f type A or type B devices; or b) on the label attached to the transformer in which the device is housed, and in the case of type C devices with: 1) the number of this European Standard, i.e. EN 50107-2; 2) the items specified in EN 61347-1:2001, Subclause 7.1 a), b), f), and l), with the words “ear

44、th-leakage protective device” or “open-circuit protective device” (as appropriate) substituted for “lamp controlgear”. 7.2 Durability of marking The durability of the marking shall conform to the requirements of EN 61347-1:2001, Subclause 7.2. 7.3 Additional information In addition to the items spec

45、ified in 7.1, the following information, if applicable, shall be given in the manufacturers instructions to be provided with both earth-leakage and open-circuit protective devices: a) the items specified in EN 61347-1:2001, Subclause 7.1 h), i) and k), with the words “earth- leakage protective devic

46、e” or “open-circuit protective device” (as appropriate) substituted for “lamp controlgear”; EN 50107-2:2005 - 8 - b) the information necessary for the test specified in EN 50107-1:2002, Clause 18, to be carried out; c) the information necessary for the safe installation of the device in accordance w

47、ith the requirements of EN 50107-1; d) the information necessary for the device to be disabled manually for maintenance purposes; e) for type A or type C protective devices, the maximum ambient temperature at which the transformer may operate to ensure that the earth-leakage device or open-circuit p

48、rotective device (as appropriate) operates safely; f) for type B protective devices, the maximum ambient temperature at which the device may operate to ensure that the earth-leakage or open-circuit protection (as appropriate) operates safely; g) where the sensors of a number of transformers are conn

49、ected to a single protective device that is connected in the mains supply to their input circuits, the number of sensors that may be connected to one protective device; h) for type B earth-leakage protective devices or open-circuit protective devices (as appropriate), information on the types and range of transformers for which the device is suitable; i) a warning against using the device in a circuit with a dimmer, unless special arrangements are made to ensure that the o