EN 61386-22-2004 en Conduit systems for cable management Part 22 Particular requirements C Pliable conduit systems (Incorporates Amendment A11 2010)《电缆管理用导管系统 第22部分 可弯曲的导管系统特殊要求 IE.pdf

上传人:李朗 文档编号:720178 上传时间:2019-01-04 格式:PDF 页数:18 大小:902.85KB
下载 相关 举报
EN 61386-22-2004 en Conduit systems for cable management Part 22 Particular requirements C Pliable conduit systems (Incorporates Amendment A11 2010)《电缆管理用导管系统 第22部分 可弯曲的导管系统特殊要求 IE.pdf_第1页
第1页 / 共18页
EN 61386-22-2004 en Conduit systems for cable management Part 22 Particular requirements C Pliable conduit systems (Incorporates Amendment A11 2010)《电缆管理用导管系统 第22部分 可弯曲的导管系统特殊要求 IE.pdf_第2页
第2页 / 共18页
EN 61386-22-2004 en Conduit systems for cable management Part 22 Particular requirements C Pliable conduit systems (Incorporates Amendment A11 2010)《电缆管理用导管系统 第22部分 可弯曲的导管系统特殊要求 IE.pdf_第3页
第3页 / 共18页
EN 61386-22-2004 en Conduit systems for cable management Part 22 Particular requirements C Pliable conduit systems (Incorporates Amendment A11 2010)《电缆管理用导管系统 第22部分 可弯曲的导管系统特殊要求 IE.pdf_第4页
第4页 / 共18页
EN 61386-22-2004 en Conduit systems for cable management Part 22 Particular requirements C Pliable conduit systems (Incorporates Amendment A11 2010)《电缆管理用导管系统 第22部分 可弯曲的导管系统特殊要求 IE.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 61386-22:2004Conduit systems for cable management Part 22: Particular requirements Pliable conduit systems ICS 29.120.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g

2、60g3g38g50g51g60g53g44g42g43g55g3g47g36g58+A :20111 0National forewordThis British Standard is the UK implementation of EN 61386-22:2004+A11:2010. It is identical to IEC 61386-22:2002. It supersedes BS EN 61386-22:2004, which is withdrawn.The UK participation in its preparation was entrusted to Tech

3、nical Committee PEL/213, Cable management.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a Bri

4、tish Standard cannot confer immunity from legal obligations.BS EN 61386-22:2004+A11:2010This British Standard was published under the authority of the Standards Policy and Strategy Committee on 21 May 2004 BSI 2011Amendments/corrigenda issued since publicationDate Comments 30 June 2011 Implementatio

5、n of CENELEC amendment A11:2010: modification of CENELEC foreword.ISBN 978 0 580 71472 6EUROPEAN STANDARD EN 61386-22NORME EUROPENNE EUROPISCHE NORM CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnisch

6、e Normung Central Secretariat: 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61386-22:2004 E ICS 29.120.10 English version Conduit systems for cable management Part 22: Particular requirements Pliable conduit systems (IEC 6

7、1386-22:2002) Systmes de conduits pour la gestion du cblage Partie 22: Rgles particulires Systmes de conduits cintrables (CEI 61386-22:2002) Elektroinstallationsrohrsysteme fr elektrische Energie und fr Informationen Teil 22: Besondere Anforderungen fr biegsame Elektroinstallationsrohrsysteme(IEC 61

8、386-22:2002) This European Standard was approved by CENELEC on 2003-09-23. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bib

9、liographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibil

10、ity of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, I

11、celand, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. A11 : 2004+December 2010Avenue Marnix 17, B - 1000 Brussels Foreword The text of the International Standard IEC 61386-22:2002, prepa

12、red by SC 23A, Cable management systems, of IEC TC 23, Electrical accessories, was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 61386-22 on 2003-09-23. This European Standard supersedes EN 50086-2-2:1995 + corrigendum February 2001 + A11:1998 + A11:1998/corrigendum

13、February 2001. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2004-10-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-0

14、6-30 This part 22 supplements or modifies the corresponding clauses of EN 61386-1. Where a particular clause or subclause of part 1 is not mentioned in this part 22, that clause or subclause applies as far as is reasonable. Where this part 22 states “addition“, “modification“ or “replacement“, the r

15、elevant text of part 1 is to be adapted accordingly. Subclauses, tables and figures which are in addition to those in part 1 are numbered starting with 101. Additional annexes are lettered AA, BB, etc. A conduit system which complies with this standard is deemed safe for use when installed in accord

16、ance with national wiring regulations, whilst applying the manufacturers installation instructions and conduit classification. In this standard, the following print types are used: - requirements: in roman type; - test specifications: in italic type; - notes: in smaller roman type. Annexes ZAA and Z

17、BB have been added by CENELEC. The contents of the corrigendum of April 2004 have been included in this copy. _ Endorsement notice The text of the International Standard IEC 61386-22:2002 was approved by CENELEC as a European Standard without any modification. _ Page 2This part 22, which specifies p

18、articular requirements for pliable conduit systems, is to be used in conjunction with EN 61386-1:2008; it may also be used in conjunction with EN 61386-1:2004 until EN 61386-1:2004 is withdrawn, the date of the withdrawal being no later than 2011-06-01. BS EN 61386-22:2004+A11:2010EN 61386-22:2004+A

19、11:2010 (E)Foreword to amendment 1 This amendment to the European Standard EN 61386-22:2004 was prepared by the Technical Committee CENELEC TC 213, Cable management systems. It was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment A11 to EN 61386-22:2004 on 2010-1

20、2-01. This amendment (affecting only the foreword) has been issued to allow the use of EN 61386-22:2004 in conjunction with EN 61386-1:2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held respons

21、ible for identifying any or all such patent rights. The following dates were fixed: latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-12-01 latest date by which the national standards conflicting w

22、ith the amendment have to be withdrawn (dow) 2013-12-01 _ Page 3BS EN 61386-22:2004+A11:2010EN 61386-22:2004+A11:2010 (E)CONTENTS 1 Scope.5 2 Normative references5 3 Definitions 5 4 General requirements .5 5 General conditions for tests 5 6 Classification 5 7 Marking and documentation 5 8 Dimensions

23、.6 9 Construction .7 10 Mechanical properties.7 11 Electrical properties 9 12 Thermal properties .9 13 Fire effects .9 14 External influences .9 15 Electromagnetic compatibility9 Annex ZA (normative) Normative references to international publications with their corresponding European publications .1

24、4 Annex ZAA (normative) Special national conditions .14 Annex ZBB (informative) A-deviations .15 Figure 101 Bending test apparatus .10 Figure 102 Gauge for checking the minimum inside diameter of the conduit system after impact, bending, and resistance to heat tests 11 Figure 103 Assembly of conduit

25、 and terminating conduit fitting for bonding test.12 Table 101 Thread lengths.6 Table 102 Maximum entry diameter and minimum entry length details 7 Page 4BS EN 61386-22:2004+A11:2010EN 61386-22:2004+A11:2010 (E)CONDUIT SYSTEMS FOR CABLE MANAGEMENT Part 22: Particular requirements Pliable conduit sys

26、tems 1 Scope This clause of part 1 is applicable, except as follows: Addition: This part of IEC 61386 specifies the requirements for pliable conduit systems including self-recovering conduit systems. 2 Normative references This clause of part 1 is applicable. 3 Definitions This clause of part 1 is a

27、pplicable. 4 General requirements This clause of part 1 is applicable. 5 General conditions for tests This clause of part 1 is applicable. 6 Classification This clause of part 1 is applicable, except as follows: 6.1.1 1, 6.1.2 1, 6.1.3 1, 6.1.3 4, 6.1.4 1 and 6.1.5 1 are not applicable. NOTE Pliable

28、 conduit systems according to 6.1.1.2 and 6.1.2.2 and classification 1X from 6.2.1, table 1 are not allowed in France. 7 Marking and documentation This clause of part 1 is applicable, except as follows: Addition: 7.1.101 The conduit shall be marked in accordance with 7.1 along its entire length at r

29、egular intervals of preferably 1 m but not longer than 3 m. Where this is technically impractical, the mark shall be on a label attached to the product at each end or on the packaging. Compliance is checked by inspection. Page 5BS EN 61386-22:2004+A11:2010EN 61386-22:2004+A11:2010 (E)7.1.102 The man

30、ufacturer shall document for the system the minimum inside diameter and the classification in accordance with clause 6. Compliance is checked by inspection. 8 Dimensions Replacement: 8.1 Threads shall comply with IEC 60423. Outside diameters of non-metallic conduit shall comply with IEC 60423. Outsi

31、de diameters of metallic and composite conduits need not comply with IEC 60423, provided that they are designed to be installed only with terminating conduit fittings having threads complying with IEC 60423. Compliance is checked by means of the gauges specified in IEC 60423. 8.2 Threadable conduits

32、 and threadable conduit fittings, except terminating conduit fittings, shall comply with table 101. Non-threadable conduit fittings, except fittings which are part of a conduit system declaring tensile strength, shall comply with table 102. The minimum inside diameter of the conduit system shall be

33、as declared by the manufacturer. Compliance is checked by measurement. Table 101 Thread lengths External thread Internal thread Size Minimum length mm Minimum length mm 6 8 10 12 16 20 25 32 40 50 63 75 05,5 06,5 08,5 10,5 12,5 14,0 17,0 19,0 19,0 19,0 19,0 19,0 06,5 07,5 09,5 11,5 13,5 15,0 18,0 20

34、,0 20,0 20,0 20,0 20,0 Page 6BS EN 61386-22:2004+A11:2010EN 61386-22:2004+A11:2010 (E)Table 102 Maximum entry diameter and minimum entry length details External thread Internal thread Size Maximum entry diametermm Minimum entry length mm 6 8 10 12 16 20 25 32 40 50 63 75 06,5 08,5 10,5 12,5 16,5 20,

35、5 25,5 32,6 40,7 50,8 63,9 75,9 06,0 08,0 10,0 12,0 16,0 20,0 25,0 30,0 32,0 42,0 50,0 50,0 9 Construction This clause of part 1 is applicable. 10 Mechanical properties This clause of part 1 is applicable, except as follows: 10.2 Compression test For self-recovering conduits, replace paragraphs 10.2

36、.4, 10.2.5, 10.2.6, 10.2.7 and 10.2.8, by the following: 10.2.101 The intermediate steel piece shall be subjected to a uniformly increasing compression force (N) reaching the force indicated in table 4 after (30 3) s. The sample shall flatten by between 25 % and 50 % of its initial outside diameter.

37、 If the sample flattens by less than 25 %, an additional test is carried out whereby the intermediate steel piece is lowered onto the sample at constant speed until the sample is flattened by (30 3) % after (30 3) s and the resultant force is measured. A new sample is subjected to the uniformly incr

38、easing force (N) reaching the force measured above after (30 3) s. The sample shall flatten by between 25 % and 50 % of its initial outside diameter. The force and the intermediate steel piece shall then be removed. Fifteen minutes after removal, the outside diameter of the sample, where it has flat

39、tened, shall be measured again. Page 7BS EN 61386-22:2004+A11:2010EN 61386-22:2004+A11:2010 (E)After the test, the difference between the initial outside diameter and the outside diameter of the flattened sample shall not exceed 10 % of the outside diameter, as measured before the test, and the samp

40、le shall show no cracks visible to normal or corrected vision without magnification. 10.4 Bending test Replacement: 10.4.101 Conduits shall be subjected to a bending test by means of the apparatus as shown in figure 101. 10.4.102 The test shall be made on six samples of conduit, the length of each s

41、ample being at least: a) 30 times the nominal outside diameter for plain conduits; b) 12 times the nominal outside diameter for corrugated conduits. Three of the samples shall be tested at ambient temperature; the other three shall be tested at the minimum declared transport, application and install

42、ation temperature according to table 1, with a tolerance of 2 C. 10.4.103 For the test at ambient temperature, the sample shall be clamped vertically in the bending apparatus as shown in figure 101. The sample shall be slowly bent by hand to the left through an angle of (90 5), back to the vertical

43、position, to the right through an angle of (90 5), and back to the vertical position. This sequence of operations shall be repeated three more times but at the end the sample shall not be bent back to the vertical position. The sample shall be maintained in the bent position for 5 min, after which i

44、t shall be placed in such a position that the straight portions are at an angle of (45 + 5) to the vertical, one end of the sample pointing upwards and the other downwards. For the test at the minimum declared transport, application and installation temperature according to table 1, the sample clamp

45、ed in the bending apparatus as shown in figure 101 shall be conditioned for 2 h in a cold chamber at this temperature with a tolerance of 2 C. After the test, the sample shall show no cracks visible to normal or corrected vision without magnification and it shall be possible to pass the appropriate

46、gauge, as shown in figure 102, through the sample under its own weight and without any initial speed. 10.5 Flexing test This subclause of part 1 is not applicable. 10.6 Collapse test This subclause of part 1 is not applicable. 10.7 Tensile strength This subclause of part 1 is applicable, except as f

47、ollows: 10.7.3 Not applicable. Page 8BS EN 61386-22:2004+A11:2010EN 61386-22:2004+A11:2010 (E)11 Electrical properties This clause of part 1 is applicable, except as follows: 11.2 Bonding test Replacement A sample of a conduit and terminating conduit fitting shall be assembled in accordance with the

48、 manufacturers instructions and mounted as shown in figure 103. A current of 25 A, having a frequency of 50 Hz to 60 Hz, derived from an a.c. source having a no-load voltage not exceeding 12 V, shall be passed through the assembly for 50min1+s. Then the voltage drop shall be measured between the poi

49、nts as shown in figure 103 and the resistance calculated from the current and this voltage drop. The resistance shall not exceed 0,05 . Where special devices are required for the coupling of conduit and terminating conduit fittings, they shall be sufficient to remove the protective coating from the conduit, or the protective finish shall be removed in accordance with the manufacturers instructions. 12 Thermal properties This clause of part 1 is applicable, except as follows: 12.3 Replacement: Th