1、 ETSI TS 100 671 V1.3.1 (2004-07)Technical Specification Transmission and Multiplexing (TM);Passive optical components;Optical fibre connectors for single mode opticalfibre communication systems;Common requirements and conformance testingETSI ETSI TS 100 671 V1.3.1 (2004-07) 2 Reference RTS/TM-01100
2、 Keywords optical, transmission, connector, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important no
3、tice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portab
4、le Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information
5、on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, send your comment to: editoretsi.org Copyright Notification No part may be reproduced except as authorized by written permission. The copyrigh
6、t and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2004. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trade Marks of ETSI registered for the benefit of its Members. TIPHONTMand the TIPHON logo are Trade Marks currently bein
7、g registered by ETSI for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI TS 100 671 V1.3.1 (2004-07) 3 Contents Intellectual Property Rights4 Foreword.4 1 Scope 5 2 References 5 3 Definition and a
8、bbreviations 6 3.1 Definition .6 3.2 Abbreviations .6 4 Details, measurements and performance requirements for ETSI environmental classes 3.1, 3.2, 3.3 and IEC environmental category U 6 4.1 Visual inspection 6 4.1.1 Overall inspection of connectors 6 4.1.2 Inspection of the end face .6 4.2 Dimensio
9、ns and mechanical measurements accuracy 6 4.3 Attenuation.7 4.3.1 Attenuation against a reference connector 7 4.3.2 Attenuation of random mated connectors .7 4.4 Return Loss (RL) of random mated connectors .7 4.5 Vibration (sinusoidal).8 4.6 Fibre/Cable retention8 4.7 Torsion .9 4.8 Bending moment 9
10、 4.9 Cable Flexing .9 4.10 Strength of coupling mechanism10 4.11 Impact.10 4.12 Static side load .10 4.13 Cold11 4.14 Dry heat11 4.15 Damp heat (steady state) 11 4.16 Change of temperature .12 4.17 Mechanical endurance12 4.18 Damp heat (cycling) .13 4.19 Intermateability 13 4.19.1 Attenuation measur
11、ement .13 4.19.2 Return loss measurement 14 4.19.3 Change of temperature14 4.19.4 Mechanical endurance 14 4.19.5 Strength of coupling mechanism 14 5 Acceptance criteria.14 5.1 Minimum sample size for qualification14 5.1.1 Qualification to minimum uniform.14 5.2 Pass/fail criteria 15 History 16 ETSI
12、ETSI TS 100 671 V1.3.1 (2004-07) 4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI
13、 SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IP
14、R Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Tec
15、hnical Specification (TS) has been produced by ETSI Technical Committee Transmission and Multiplexing (TM). The present document is a revision of ES 200 671. ETSI ETSI TS 100 671 V1.3.1 (2004-07) 5 1 Scope The present document specifies requirements of connector sets to be used in single-mode optica
16、l fibre telecommunication systems and it applies only to pigtailed connectors, not patchcords. The scope covers the establishment of minimum uniform requirements for the following aspects: - optical, environmental and mechanical properties; - test conditions; - acceptance criteria. Reliability aspec
17、ts of connector sets are not covered by the present document. Some users may have additional specific requirements, such as a need to verify performance at lower temperatures. These users should specify connectors conforming to the basic ETSI performance standard, plus additional tests or more sever
18、e test conditions. Connectors for different applications which fall within the scope of the present document have common environmental and mechanical stability requirements, but there are three grades of attenuation requirement and three grades of return loss. The attenuation grades are designated B
19、,C and D The return loss grades are designated 1, 2 and 3 Test methods are in accordance with IEC 61300 series 2. For a definition of a connector set, see clause 3.1 of the present document. 2 References The following documents contain provisions which, through reference in this text, constitute pro
20、visions of the present document. References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. Referenced documents whi
21、ch are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. 1 IEC 60874-1 (including amendment 1): “Connectors for optical fibres and cables - Part 1: Generic specification“. 2 IEC 61300 (all parts): “Fibre optic interconnecting devices and p
22、assive components - Basic test and measurement procedures“. 3 ETSI EN 300 019-1-3: “Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-3: Classification of environmental conditions; Stationary use at weatherprotected locations“.
23、4 ETSI ES 200 671: “Transmission and Multiplexing (TM); Passive optical components; Fibre optical connectors for single-mode optical fibre communication systems; Common requirements and conformance testing“. 5 IEC 61753 -1: “Fibre optic interconnecting devices and passive components - Part 1: Genera
24、l and guidance for performance standard“. 6 EN 50377 (all parts): “Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications“. ETSI ETSI TS 100 671 V1.3.1 (2004-07) 6 3 Definition and abbreviations 3.1 Definition For the purposes of the pre
25、sent document, the following terms and definitions apply: connector set: complete set of connector components required to provide demountable coupling between one or more pairs of optical fibres 3.2 Abbreviations For the purposes of the present document, the following abbreviations apply: OTDR Optic
26、al Time Domain Reflectometer RL Return Loss SFF Small Form Factor (connectors with ferrule diameter of 1,25 mm) 4 Details, measurements and performance requirements for ETSI environmental classes 3.1, 3.2, 3.3 and IEC environmental category U All measurements shall be carried out under normal room c
27、onditions, unless otherwise stated. Before the insertion and return loss measurement, careful cleaning in accordance with manufacturers instructions is necessary. All optical tests shall be carried out in both the 1 310 nm window and the 1 550 nm window unless otherwise stated. Light sources with pe
28、ak wavelengths of 1 310 nm 30 nm and 1 550 nm 30 nm shall be used. The length of fibre or cable on each side of the connector set shall be 1,5 m (minimum). A minimum length of 1,5 m on each side of the test set shall be exposed to the test conditions of all climatic and environmental tests. 4.1 Visu
29、al inspection 4.1.1 Overall inspection of connectors Each connector shall be properly packed. The package shall be marked with the name of the manufacturer and the production date. The connector itself shall be legibly and durably marked with the identity mark of the manufacturer and the manufacturi
30、ng date code (see IEC 61300-3-1 2). 4.1.2 Inspection of the end face The end face shall be clean and free from residues of glue. No scratches or break out of glass pieces shall be seen when using a microscope with a maximum magnification of 200 times. The inspection shall be performed in accordance
31、with IEC 61300-3-42 2 PAS and meet the requirements as stated in that document. 4.2 Dimensions and mechanical measurements accuracy Measurement accuracy and standardization shall be established to ensure consistency of production and consistency of performance of inter-mated connectors from differen
32、t sources. Mechanical measurement accuracy shall be demonstrated to be in accordance with IEC 60874-1 1 amendment 1. ETSI ETSI TS 100 671 V1.3.1 (2004-07) 7 4.3 Attenuation 4.3.1 Attenuation against a reference connector Details: In accordance with IEC 61300-3-4 2, method 7 (measurements against a r
33、eference plug). Reference plug: Type A): For qualification testing to determine the loss of connector sets when one side is a defined reference, the eccentricity of the reference connector plug (centre of fibre core to centre of ferrule) shall be 0,3 m. The reference plug shall in all other respects
34、 conform to the same detail or product specification as the connector under test. Type B): For environmental, mechanical and climatic testing detailed in the present document, the reference plug shall be selected randomly from the regular production of the connector sets that are undergoing qualific
35、ation testing. For these tests, the initial loss of the connector sets that are to be tested shall be less than 1,0 dB for plugs conforming to grade D or less than 0,50 dB for plugs conforming to grade C and less than 0,25 for plugs conforming to grade B. Only the fundamental mode shall propagate at
36、 the connector interface and at the detector. Requirements: Attenuation: 0,50 dB when mated to reference plug Type A. (This is the maximum for any mating of plugs of grade D and C , and ). 0,30 dB when mated to reference plug Type A ( This is the maximum for any mating of plugs of grade B). 4.3.2 At
37、tenuation of random mated connectors Details: In accordance with IEC 61300-3-34 2. Only the fundamental mode shall propagate at the connector interface and at the detector. Statistical attenuation requirements: attenuation grade D: Mean 0,50 dB; 1,0 dB maximum for 97 % of mating combinations. attenu
38、ation grade C: Mean 0,25 dB; 0,50 dB maximum for 97 % of mating combinations. attenuation grade B: Mean 0,12 dB; 0,25 dB maximum for 97 % of mating combinations. 4.4 Return Loss (RL) of random mated connectors Details: In accordance with IEC 61300-3-6 method 2 (coupler method) 2: launch fibre length
39、 (L): 2 m L 4 m; source stability: Better than 0,20 dB over the measurement period. Alternatively, the return loss may be measured using an Optical Time Domain Reflectometer (OTDR) in accordance with IEC 61300-3-6 2 method 2. It is recommended to calibrate OTDR against coupler based measurements or
40、reference reflector. ETSI ETSI TS 100 671 V1.3.1 (2004-07) 8 Reference connector: The reference connector shall conform to the same product specification as the connector under test. Requirements: RL (minimum return loss for every mating): RL grade 3: 35 dB for low reflection connectors (as measured
41、 when mated); RL grade 2 45 dB for ultra low reflection connectors (as measured when mated); RL grade 1 60 dB for ultra low reflection connectors as measured when mated and 55 dB as measured when unmated). 4.5 Vibration (sinusoidal) Details: In accordance with IEC 61300-2-1 2: frequency range: 10 Hz
42、 to 55 Hz; endurance duration per axis: 0,5 hour; number of axes: three, orthogonal; number of cycles (10-55-10): 15; vibration amplitude: 0,75 mm. Requirements: allowable attenuation variation: 0,20 dB, measured at 1 550 nm 30 nm; allowable return loss variation: return loss shall not fall below th
43、e minimum for the grade. The attenuation shall be measured at 1 550 nm 30 nm before, during and after the test as specified in clause 4.3.1. The sampling interval during the test shall be 2 ms. The measurement during shall be done according IEC 61300-3-28 2 measurement method for transient loss. The
44、 return loss shall be measured as specified in clause 4.4 before, and after the test, at 1 550 nm 30 nm. 4.6 Fibre/Cable retention Details: In accordance with IEC 61300-2-4 2: magnitude and rate of application of the tensile load: 100 N 5 N applied at 5 N/s for reinforced cables; 70 N 5 N applied at
45、 5 N/s for reinforced cables and SFF connectors;5 N 0,5 N applied at 0,5 N/s for coated fibres. duration of the test (maintaining the load): 120 s for reinforced cables; 60 s for coated fibres. point of application of the tensile load: 0,3 m from the end-face of the connector. Requirements: allowabl
46、e attenuation variation: 0,20 dB, measured at 1 550 nm 30 nm; allowable return loss variation: return loss shall not fall below the minimum for the grade. ETSI ETSI TS 100 671 V1.3.1 (2004-07) 9 The attenuation shall be measured at 1 550 nm 30 nm before, during and after the test as specified in cla
47、use 4.3.1. During the test the attenuation shall be measured at least once while the load is at the maximum level. The return loss shall be measured as specified in clause 4.4 before, during and after the test, at 1 550 nm 30 nm. During the test the return loss shall be measured at least once while
48、the load is at the maximum level. 4.7 Torsion Details: In accordance with IEC 61300-2-5 2: magnitude of the tensile load: 15 N for reinforced cable; 2 N for coated fibre. point of application of the tensile load: 0,2 m from the end face of the connector; duration of the test: 25 cycles (not to excee
49、d the cable specification). Requirements: allowable attenuation variation: 0,20 dB, measured at 1 550 nm 30 nm. The attenuation shall be measured at 1 550 nm 30 nm before and after the test as specified in clause 4.3.1. 4.8 Bending moment Details: In accordance with IEC 61300-2-7 2 magnitude of the load: 10 N; point of application of the tensile load: 25 mm from the centre line defined by the optical interface; duration of the test: 5 s. Requirements: allowable attenuatio