ETSI TS 102 566-2007 Access Terminals Transmission and Multiplexing (ATTM) Common Requirements for Automated Distribution Frames (ADF) at Street Cabinet《接入终端 传输和复用(ATTM) 街道机柜上自动配线架.pdf

上传人:towelfact221 文档编号:739211 上传时间:2019-01-12 格式:PDF 页数:22 大小:172.42KB
下载 相关 举报
ETSI TS 102 566-2007 Access Terminals Transmission and Multiplexing (ATTM) Common Requirements for Automated Distribution Frames (ADF) at Street Cabinet《接入终端 传输和复用(ATTM) 街道机柜上自动配线架.pdf_第1页
第1页 / 共22页
ETSI TS 102 566-2007 Access Terminals Transmission and Multiplexing (ATTM) Common Requirements for Automated Distribution Frames (ADF) at Street Cabinet《接入终端 传输和复用(ATTM) 街道机柜上自动配线架.pdf_第2页
第2页 / 共22页
ETSI TS 102 566-2007 Access Terminals Transmission and Multiplexing (ATTM) Common Requirements for Automated Distribution Frames (ADF) at Street Cabinet《接入终端 传输和复用(ATTM) 街道机柜上自动配线架.pdf_第3页
第3页 / 共22页
ETSI TS 102 566-2007 Access Terminals Transmission and Multiplexing (ATTM) Common Requirements for Automated Distribution Frames (ADF) at Street Cabinet《接入终端 传输和复用(ATTM) 街道机柜上自动配线架.pdf_第4页
第4页 / 共22页
ETSI TS 102 566-2007 Access Terminals Transmission and Multiplexing (ATTM) Common Requirements for Automated Distribution Frames (ADF) at Street Cabinet《接入终端 传输和复用(ATTM) 街道机柜上自动配线架.pdf_第5页
第5页 / 共22页
点击查看更多>>
资源描述

1、 ETSI TS 102 566 V1.1.1 (2007-09)Technical Specification Access Terminals, Transmission and Multiplexing (ATTM);Common Requirements for Automated Distribution Frames (ADF)at Street CabinetETSI ETSI TS 102 566 V1.1.1 (2007-09) 2 Reference DTS/ATTM-02002 Keywords access ETSI 650 Route des Lucioles F-0

2、6921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.et

3、si.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing o

4、n ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal

5、.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the for

6、egoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2007. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trade Marks of ETSI registered for the benefit of its Members. TIPHONTMand the TIPHON logo are Trade Marks currently being registered

7、by ETSI for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI TS 102 566 V1.1.1 (2007-09) 3 Contents Intellectual Property Rights4 Foreword.4 1 Scope 5 2 References 5 2.1 Normative references .5 3 A

8、bbreviations .6 4 General description of ADF .7 4.1 Main functionalities9 4.2 Available technologies .11 4.3 Application scenarios .11 5 Requirements12 5.1 Transmission Requirements .12 5.2 Electrical requirements.13 5.2.1 DC Characteristics 13 5.2.2 Electrical protection toward overvoltages.13 5.2.

9、3 Electrical safety 13 5.2.4 Electromagnetic compatibility13 5.2.5 Powering and consumption.13 5.3 Environmental requirements 14 5.3.1 Operating environment .14 5.3.2 Protection against mechanical actions/vibration.14 5.3.3 Protection against corrosion of metallic elements 14 5.3.4 Protection agains

10、t heat and fire.14 5.4 Mechanical requirements .14 5.5 Functional Requirements15 5.5.1 Switching functionalities 15 5.5.2 Test ports functionalities.15 5.5.3 Diagnostic functionalities .15 5.5.4 Reliability and behavior in case of failure 16 5.5.5 Card handling and replacement 16 5.5.6 Automatic rer

11、outing16 5.5.7 Interconnection and Cabling.16 5.6 Management Requirements16 5.6.1 Architectural scenario.17 5.6.2 Faults 17 5.6.3 Configuration17 5.6.4 Security.18 5.6.5 Interfaces and MIBs usage permission .18 5.6.6 Inventory.19 Annex A (informative): Proforma for possible ADF configurations and pa

12、rameters .20 History 22 ETSI ETSI TS 102 566 V1.1.1 (2007-09) 4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-memb

13、ers, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.

14、asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the p

15、resent document. Foreword This Technical Specification (TS) has been produced by ETSI Technical Committee Access, Terminals, Transmission and Multiplexing (ATTM). ETSI ETSI TS 102 566 V1.1.1 (2007-09) 5 1 Scope Due to the requirements for the spreading of xDSL based broadband services, in particular

16、 combining more confined coverage areas, faster speeds and multiple services support, operators have primary interest in solutions for automated distribution frames in street cabinets and operators room down to the building. The present document gathers a first set of common requirements for ADF (Au

17、tomated Distribution Frames) systems in configurations for street cabinets. The aim of the present document is also to have an integrated view of the architecture, configurations and related management systems required to maintain the overall systems at street cabinets, as todays evolution scenarios

18、 predict the possibility of having automated distribution frames spread across networks. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For a specific reference, subsequent revisions do not apply. Non-specific

19、reference may be made only to a complete document or a part thereof and only in the following cases: - if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document; - for informative references. Referenced documents which

20、are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. For online referenced documents, information sufficient to identify and locate the source shall be provided. Preferably, the primary source of the referenced document should be cited, i

21、n order to ensure traceability. Furthermore, the reference should, as far as possible, remain valid for the expected life of the document. The reference shall include the method of access to the referenced document and the full network address, with the same punctuation and use of upper case and low

22、er case letters. NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the

23、 edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies. 1 ETSI EN 300 386: “Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirem

24、ents“. 2 ETSI ES 201 468: “Electromagnetic compatibility and Radio spectrum Matters (ERM); Additional ElectroMagnetic Compatibility (EMC) requirements and resistibility requirements for telecommunications equipment for enhanced availability of service in specific applications“. 3 ETSI TS 101 270-1 (

25、V1.3.1, clauses 8.1.1 and 9.2): “Transmission and Multiplexing (TM); Access transmission systems on metallic access cables; Very high speed Digital Subscriber Line (VDSL); Part 1: Functional requirements“. 4 ETSI ES 201 468: “Electromagnetic compatibility and Radio spectrum Matters (ERM); Additional

26、 ElectroMagnetic Compatibility (EMC) requirements and resistibility requirements for telecommunications equipment for enhanced availability of service in specific applications“. ETSI ETSI TS 102 566 V1.1.1 (2007-09) 6 5 ETSI EN 300 132-2: “Environmental Engineering (EE); Power supply interface at th

27、e input to telecommunications equipment; Part 2: Operated by direct current (dc)“. 6 ETSI EN 300 119-5: “Environmental Engineering (EE); European telecommunication standard for equipment practice; Part 5: Thermal management“. 7 ETSI EN 300 019-2-3: “Environmental Engineering (EE); Environmental cond

28、itions and environmental tests for telecommunications equipment; Part 2-3: Specification of environmental tests; Stationary use at weatherprotected locations“. 8 ETSI EN 300 119: “Environmental Engineering (EE); European telecommunication standard for equipment practice; Part 1: Introduction and ter

29、minology“. 9 ETSI EN 300 253: “Environmental Engineering (EE); Earthing and bonding of telecommunication equipment in telecommunication centres“. 10 ETSI EN 300 386: “Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (E

30、MC) requirements“. 11 IEC EN 60439-5: “ Low-voltage switchgear and controlgear assemblies - Part 5: Particular requirements for assemblies for power distribution in public networks“. 12 IEC EN 60068-2-11: “Basic Environmental Testing Procedures - Part 2: Tests“. 13 IEC EN 60062: “Marking codes for r

31、esistors and capacitors“. 14 Directive 73/23/EEC Council Directive of 19 February 1973 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits and Council Directive 93/68/EEC of 22 July 1993 amending Directives 87/404/EEC (sim

32、ple pressure vessels), 88/378/EEC (safety of toys), 89/106/EEC (construction products), 89/336/EEC (electromagnetic compatibility), 89/392/EEC (machinery), 89/686/EEC (personal protective equipment), 90/384/EEC (non-automatic weighing instruments), 90/385/EEC (active implantable medicinal devices),

33、90/396/EEC (appliances burning gaseous fuels), 91/263/EEC (telecommunications terminal equipment), 92/42/EEC (new hot-water boilers fired with liquid or gaseous fuels) and 73/23/EEC (electrical equipment designed for use within certain voltage limits)“. 15 ITU-T Recommendation K.20: “Resistibility o

34、f telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents“. 16 ITU-T Recommendation K.44: “Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents - Basic Recommendation“. 17 ITU-T Recommendation K.45: “Resistibility

35、of telecommunication equipment installed in the access and trunk networks to overvoltages and overcurrents“. 18 IEC EN 60950: “Information technology equipment - Safety“. 3 Abbreviations For the purposes of the present document, the following abbreviations apply: ACK ACKnowledge ADF Automatic Distri

36、bution Frame ADSL Asymmetric Digital Subscriber Line API Application Programming Interface BSS Business Support System CLI Command Line Interface CLR CLeaR CORBA Common Object Request Broker Architecture CPU Central Processing Unit DB DataBase DC Direct Current ETSI ETSI TS 102 566 V1.1.1 (2007-09)

37、7 DSLAM Digital Subscriber Line Access Multiplexer EMS Element Manager System FCAPS Fault, Configuration, Accounting, Performance and Security FTP File Transfer Protocol FTTB Fiber To The Building FTTCab Fiber To The Cabinet GUI Graphical User Interface HW HardWare IDC Insulation Displacement Connec

38、tor ISDN Integrated Services Digital Network M Mandatory MEMS Micro Electro-Mechanical Systems MIB Management Information dataBase MS Management System NE Network Element NMS Network Management System OAM Operations, Administration and Maintenance OC Object Code (object under transaction for the MS)

39、 ONU Optical Network Unit OS Operating System OSS Operational Support Systems P Preferential PCM Pulse-Code Modulation POTS Plain Old Telephone Service PTC positive temperature coefficient (resistor) RMI Remote Method Invocation RPC Remote Procedure Call SNMP Simple Network Management Protocol SSH S

40、ecure Shell Protocol SW SoftWare TFTP Trivial File Transfer Protocol TL1 Transaction Language 1 TLC TeLeCommunicationVDSL Very-high-Data-rate digital Subscriber Line XML eXtensible Markup Language 4 General description of ADF ADF replaces or supports/complements the manual distribution frame to inte

41、rconnect each subscriber line with the specific equipment to cope with the automated provision of appropriate services and multi-operator connectivity. It minimizes the need for on-site labor to physically make cross-connects and to verify service installation, reduces operational costs and maintena

42、nce and improves service delivery cycles. In order to take advantage of all the functionality of the Automatic Distribution Frame, the following requirements need to be met: NON-BLOCKING CONNECTIVITY: the ability to switch any facility pair to any equipment pair regardless of existing connections or

43、 port utilization in the system. This requirement is set for Any-to-any ADF, while for the any-to-many solution a certain percentage of blocking is allowed. SCALABILITY: to cost-effectively scale to meet different size requirements, implementations should privilege highly modular growth capability i

44、n order to optimize the available space and port requirements. CAPACITY: the maximum number of ports in a cabinet taking into account the number of operators, subscriber lines, equipments (testing included) should typically match configurations of 600 x 600 and/or 900 x 600 lines. RELIABILITY: to gu

45、arantee an extremely high degree of confidence that connections are made correctly upon request. In addition, as the distribution frame is an essential component to provide connectivity to millions of subscribers, it must have an extremely low failure rate and long life expectancy. ETSI ETSI TS 102

46、566 V1.1.1 (2007-09) 8 AUTOMATIC CONNECTION VERIFICATION AND ONGOING TESTING: the ability to remotely connect any line terminating on the frame to a testing system. This testing system, not included in the ADF solution, has to verify that connections were made correctly and are working properly. Thi

47、s testing system can be used to assist with service provisioning, fault isolation, and on going monitoring of the circuit. INSTALLATION: in street cabinets, the input, output and matrix stages should be able to be installed and cabled either placing the system in a slot horizontally or vertically. I

48、nstallation details should be provided for these specific small cabinets/small system capacities. The connections must be made correctly upon request. Maximum interconnection cable length: 2 mt 10 mt (depending on ADF location - in the same cabinet or in a different one/manhole). Types of cables sup

49、ported: twisted pair cables, broadband capable. OPERATION SUPPORT SYSTEM (OSS) INTEGRATION: must be closely integrated with service activation, inventory and workflow systems so that cross-connections can automatically take place as part of an end-to-end software-driven process flow. In addition, by tying in the distribution frame with existing fault management systems, problems can be proactively isolated and rapidly resolved with minimum human intervention. All operators can access to test functionalities. Figure 1 pre

展开阅读全文
相关资源
猜你喜欢
  • ASTM E2050-2012a Standard Test Method for Determination of Total Carbon in Mold Powders by Combustion《通过燃烧测定铸型粉末中全碳量的标准试验方法》.pdf ASTM E2050-2012a Standard Test Method for Determination of Total Carbon in Mold Powders by Combustion《通过燃烧测定铸型粉末中全碳量的标准试验方法》.pdf
  • ASTM E2050-2017 Standard Test Method for Determination of Total Carbon in Mold Powders by Combustion《采用燃烧法测定保护渣总碳含量的标准试验方法》.pdf ASTM E2050-2017 Standard Test Method for Determination of Total Carbon in Mold Powders by Combustion《采用燃烧法测定保护渣总碳含量的标准试验方法》.pdf
  • ASTM E2056-2004 Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses Calibrated Using Surrogate Mixtures《使用代用品混合物校正的多变量分析中使用的分光计和分.pdf ASTM E2056-2004 Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses Calibrated Using Surrogate Mixtures《使用代用品混合物校正的多变量分析中使用的分光计和分.pdf
  • ASTM E2056-2004(2010) Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses Calibrated Using Surrogate Mixtures《使用代用品混合物校正的多变量分析中使用.pdf ASTM E2056-2004(2010) Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses Calibrated Using Surrogate Mixtures《使用代用品混合物校正的多变量分析中使用.pdf
  • ASTM E2056-2004(2016) Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses Calibrated Using Surrogate Mixtures《用于多变量分析和替代混合物校准的光谱仪.pdf ASTM E2056-2004(2016) Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses Calibrated Using Surrogate Mixtures《用于多变量分析和替代混合物校准的光谱仪.pdf
  • ASTM E2057-2000 Standard Specifications for Preparation of Laboratory Analysis Requests in Sexual Assault Investigations 《性侵犯调查中实验室分析准备的标准规范》.pdf ASTM E2057-2000 Standard Specifications for Preparation of Laboratory Analysis Requests in Sexual Assault Investigations 《性侵犯调查中实验室分析准备的标准规范》.pdf
  • ASTM E2057-2010 Standard Specifications for Preparation of Laboratory Analysis Requests in Sexual Assault Investigations《性侵犯调查中的实验室分析要求的准备工作的标准规范》.pdf ASTM E2057-2010 Standard Specifications for Preparation of Laboratory Analysis Requests in Sexual Assault Investigations《性侵犯调查中的实验室分析要求的准备工作的标准规范》.pdf
  • ASTM E2057-2010(2015) Standard Specifications for Preparation of Laboratory Analysis Requests in Sexual Assault Investigations《编制性侵犯调查中实验室研究请求的标准规范》.pdf ASTM E2057-2010(2015) Standard Specifications for Preparation of Laboratory Analysis Requests in Sexual Assault Investigations《编制性侵犯调查中实验室研究请求的标准规范》.pdf
  • ASTM E2058-2006 Standard Test Methods for Measurement of Synthetic Polymer Material Flammability Using a Fire Propagation Apparatus (FPA)《用火焰蔓延仪(FPA)测量合成聚合物材料易燃性的标准试验方法》.pdf ASTM E2058-2006 Standard Test Methods for Measurement of Synthetic Polymer Material Flammability Using a Fire Propagation Apparatus (FPA)《用火焰蔓延仪(FPA)测量合成聚合物材料易燃性的标准试验方法》.pdf