1、 FORD LABORATORY TEST METHOD BU 119-01 Date Action Revisions 2000 12 01 Revised Editorial no technical change A. Cockman 1991 05 03 Printed copies are uncontrolled Page 1 of 7 Copyright 2000, Ford Global Technologies, Inc. INDUCTION CURE TEST FOR METAL BONDING ADHESIVES Application This method is us

2、ed to determine the adhesion strength characteristics of heat-cured metal bonding adhesives subjected to induction heating. Apparatus Required Induction Equipment Schematic Diagram - See Figure 1. Power Supply A 20 kW, 10 kHz, high frequency generator. Robotron #08001-04 or equivalent. Heat Station

3、Robotron 20 kW - 10 kHz heat station to match impedance load of coil to power supply. Inductor Fabricated as shown in Figure 2. Clamping Fixture Fabricated as shown in Figure 3. Temperature Pyrometer Temperature measurement instrument with capability of 23 30 C temperature range and +/- 3 C accuracy

4、 Ircon infra-red pyrometer or equivalent. Test Coupons Test coupons shall be 25 x 100 x 0.76 mm CRLC steel body stock or otherwise specified by the applicable Engineering Material Specification. Tensile Tear Machine Instron or equivalent with an accuracy of 0.5 % of the range used. Conditioning and

5、 Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BU 119-01

6、 Page 2 of 7 Copyright 2000, Ford Global Technologies, Inc. Procedure 1. Prepare overlap shear test assemblies as shown in Figure 4. Use CRLC steel substrates unless otherwise specified in the applicable Engineering Material Specification. 2. Remove excess adhesive squeeze-out after coupon assembly

7、prior to positioning in induction clamping fixture. 3. Mount test assembly in clamping fixture, then induction heat at a schedule of 160 +/- 2 C, or as specified by the engineering document, for 4 s. Power and temperature curves representing this schedule are shown in Figure 5. 4. Condition bonded t

8、est assemblies to 23 +/- 2 C, then conduct shear pull test at a rate of 13 mm per minute. 5. Report peak load and type of separation (i.e., “adhesive“: adhesive to substrate separation; “cohesive“: separation within the adhesives). Chemicals, materials, parts, and equipment referenced in this docume

9、nt must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities. FORD LABORATORY TEST METHOD BU 119-01 Page 3 of 7 Copyright 2000, Ford Global Technologies, Inc. INDUCTION CURE TEST FOR METAL BONDING ADHESIVES Figure 1 Equipment Schematic FOR

10、D LABORATORY TEST METHOD BU 119-01 Page 4 of 7 Copyright 2000, Ford Global Technologies, Inc. INDUCTION CURE TEST FOR METAL BONDING ADHESIVES Figure 2 Inductor FORD LABORATORY TEST METHOD BU 119-01 Page 5 of 7 Copyright 2000, Ford Global Technologies, Inc. INDUCTION CURE TEST FOR METAL BONDING ADHES

11、IVES Figure 3 Clamping Fixture FORD LABORATORY TEST METHOD BU 119-01 Page 6 of 7 Copyright 2000, Ford Global Technologies, Inc. INDUCTION CURE TEST FOR METAL BONDING ADHESIVES Figure 4 Test Coupon Assembly FORD LABORATORY TEST METHOD BU 119-01 Page 7 of 7 Copyright 2000, Ford Global Technologies, Inc. INDUCTION CURE TEST FOR METAL BONDING ADHESIVES Figure 5 Power and Temperature Curves

展开阅读全文
相关资源
猜你喜欢
  • DIN EN ISO 3580-2011 Welding consumables - Covered electrodes for manual metal arc welding of creep-resisting steels - Classification (ISO 3580 2010) German version EN ISO 3580 201.pdf DIN EN ISO 3580-2011 Welding consumables - Covered electrodes for manual metal arc welding of creep-resisting steels - Classification (ISO 3580 2010) German version EN ISO 3580 201.pdf
  • DIN EN ISO 3582-2007 Flexible cellular polymeric materials - nLaboratory assessment of horizontal burning characteristics of small specimens subjected to a small flame (ISO 3582 20.pdf DIN EN ISO 3582-2007 Flexible cellular polymeric materials - nLaboratory assessment of horizontal burning characteristics of small specimens subjected to a small flame (ISO 3582 20.pdf
  • DIN EN ISO 3593-1994 Starch - Determination of ash (ISO 3593 1981) German version EN ISO 3593 1994《淀粉 灰分的测定 (ISO 3593 1981) 德文版本 EN ISO 3593 1994》.pdf DIN EN ISO 3593-1994 Starch - Determination of ash (ISO 3593 1981) German version EN ISO 3593 1994《淀粉 灰分的测定 (ISO 3593 1981) 德文版本 EN ISO 3593 1994》.pdf
  • DIN EN ISO 3596-2002 Animal and vegetable fats and oils - Determination of unsaponifiable matter - Method using diethyl ether extraction (ISO 3596 2000) German version EN ISO 3596 .pdf DIN EN ISO 3596-2002 Animal and vegetable fats and oils - Determination of unsaponifiable matter - Method using diethyl ether extraction (ISO 3596 2000) German version EN ISO 3596 .pdf
  • DIN EN ISO 361-2015 Basic ionizing radiation symbol (ISO 361 1975) German version EN ISO 361 2015《电离辐射基本符号(ISO 361-1975) 德文版本EN ISO 361-2015》.pdf DIN EN ISO 361-2015 Basic ionizing radiation symbol (ISO 361 1975) German version EN ISO 361 2015《电离辐射基本符号(ISO 361-1975) 德文版本EN ISO 361-2015》.pdf
  • DIN EN ISO 3611-2011 Geometrical product specifications (GPS) - Dimensional measuring equipment Micrometers for external measurements - Design and metrological characteristics (ISO.pdf DIN EN ISO 3611-2011 Geometrical product specifications (GPS) - Dimensional measuring equipment Micrometers for external measurements - Design and metrological characteristics (ISO.pdf
  • DIN EN ISO 3613-2011 Metallic and other inorganic coatings - Chromate conversion coatings on zinc cadmium aluminium-zinc alloys and zinc-aluminium alloys - Test methods (ISO 3613 2.pdf DIN EN ISO 3613-2011 Metallic and other inorganic coatings - Chromate conversion coatings on zinc cadmium aluminium-zinc alloys and zinc-aluminium alloys - Test methods (ISO 3613 2.pdf
  • DIN EN ISO 3630-1-2008 Dentistry - Root-canal instruments - Part 1 General requirements and test methods (ISO 3630-1 2008) English version of DIN EN ISO 3630-1 2008-04《牙科 牙根管器械 第1部.pdf DIN EN ISO 3630-1-2008 Dentistry - Root-canal instruments - Part 1 General requirements and test methods (ISO 3630-1 2008) English version of DIN EN ISO 3630-1 2008-04《牙科 牙根管器械 第1部.pdf
  • DIN EN ISO 3630-2-2013 Dentistry - Endodontic instruments - Part 2 Enlargers (ISO 3630-2 2013) German version EN ISO 3630-2 2013《牙科 牙根管器械 第2部分 扩大器(ISO 3630-2-2013 德文版本EN ISO 3630-2.pdf DIN EN ISO 3630-2-2013 Dentistry - Endodontic instruments - Part 2 Enlargers (ISO 3630-2 2013) German version EN ISO 3630-2 2013《牙科 牙根管器械 第2部分 扩大器(ISO 3630-2-2013 德文版本EN ISO 3630-2.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1