NFPA 1906 AMD 3-2017 Standard for Wildland Fire Apparatus (Effective Date 9 6 2017).pdf

上传人:bowdiet140 文档编号:1008377 上传时间:2019-03-19 格式:PDF 页数:5 大小:46.43KB
下载 相关 举报
NFPA 1906 AMD 3-2017 Standard for Wildland Fire Apparatus (Effective Date 9 6 2017).pdf_第1页
第1页 / 共5页
NFPA 1906 AMD 3-2017 Standard for Wildland Fire Apparatus (Effective Date 9 6 2017).pdf_第2页
第2页 / 共5页
NFPA 1906 AMD 3-2017 Standard for Wildland Fire Apparatus (Effective Date 9 6 2017).pdf_第3页
第3页 / 共5页
NFPA 1906 AMD 3-2017 Standard for Wildland Fire Apparatus (Effective Date 9 6 2017).pdf_第4页
第4页 / 共5页
NFPA 1906 AMD 3-2017 Standard for Wildland Fire Apparatus (Effective Date 9 6 2017).pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 Tentative Interim Amendment NFPA1906 Standard for Wildland Fire Apparatus 2016 Edition Reference: 2.3.8, 14.1.1, 14.4, A.14.4, A.14.4.3.4, A.14.1.1(new), and E.1.2.4 TIA 16-3 (SC 17-8-29 / TIA Log #1267) Pursuant to Section 5 of the NFPA Regulations Governing the Development of NFPA Standards, the

2、National Fire Protection Association has issued the following Tentative Interim Amendment to NFPA 1906, Standard for Wildland Fire Apparatus, 2016 edition. The TIA was processed by the Technical Committee on Fire Department Apparatus, and was issued by the Standards Council on August 15, 2017, with

3、an effective date of September 4, 2017. A Tentative Interim Amendment is tentative because it has not been processed through the entire standards-making procedures. It is interim because it is effective only between editions of the standard. A TIA automatically becomes a public input of the proponen

4、t for the next edition of the standard; as such, it then is subject to all of the procedures of the standards-making process. 1. Delete an entry in 2.3.8 to read as follows: 2.3.8 SAE Publications. Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096-0001 SAE J1194, Rollover

5、 Protective Structures (ROPS) for Wheeled Agriculture Tractors, 2009. 2. Revise 14.1.1 to read as follows: 14.1.1* Each crew riding position shall be within a fully enclosed personnel area except as provided in Section 14.4. 3. Delete section 14.4 through 14.4.3.6 and associated Annexes A.14.4* and

6、A.14.4.3.4 as shown: 14.4* On-Board Pump-and-Roll Fire- Fighting Position. 14.4.1 If an on-board pump-and-roll fire fighting position as described in this section is provided it shall be on a wildland fire apparatus with a GVWR of no more than 19,500 lbs. 14.4.2 If an on-board pump-and-roll fire fig

7、hting position is provided, it shall include the following: (1) A seat with an approved Type 1 seat belt for each fire- fighting position (2) Controls required by the operator within reach without removing the seat belt (3) A means of communication with the driver (4) One safety sign warning of the

8、hazards of this riding position that is substantially similar to FAMA44, which warns of riding safety procedures, and the maximum speed of 10 mph visible from the pump-and-roll fire-fighting position (5) Safety sign FAMA45, which warns of driving safety procedures, and the maximum speed of 10 mph vi

9、sible from the drivers position or visible to the driver while entering the cab 14.4.3 If the seating position is located outside the cab, it shall meet requirements in 14.4.3.1 through 14.4.3.6. 14.4.3.1 The seating position shall be located behind the cab and ahead of the rear axle. 14.4.3.2 A pro

10、tective structure shall be provided in compliance with the side impact and crush criteria from SAE J1194,Rollover Protective Structures (ROPS) for Wheeled Agricultural Tractors. 14.4.3.3 The protective structure shall be designed to allow exit out of either side of the vehicle. 14.4.3.4* The protect

11、ive structure shall include a perforated plate or mesh with openings no larger than 1.5 in. (3.8 cm) 1.5 in. (3.8 cm) or other solid guard to protect from brush hazards at the front, the back, and the roof. 14.4.3.5 A door or gate with a latching mechanism shall be provided on each side of the vehic

12、le designed to allow exit out of either side of the vehicle. 14.4.3.5.1 The door or gate shall be designed to prevent outward swing even in the event of failure of the latching mechanism. 14.4.3.5.2 The door or gate shall be at least 48 in. (1200 mm) high from the walking surface below the firefight

13、ers feet. 14.4.3.5.3 The door or gate shall be constructed so there are no horizontal or vertical openings below the 48 in. (1200 mm) minimum height greater than 24 in. (610 mm) in either direction. 14.4.3.6 Equipment located within the seating enclosure position protective structure shall meet the

14、requirements of 14.1.10 A.14.4 Typically, while engaged in fire-fighting operations on structural fires, apparatus are positioned in a safe location, and hose is extended as necessary to discharge water or suppressants on the combustible material. In wildland fire suppression, mobile attack is often

15、 utilized in addition to stationary pumping. In mobile attack, sometimes referred to as pump-and-roll, water is discharged from the apparatus while the vehicle is in motion. Pump-and-roll operations are inherently more dangerous than stationary pumping because the apparatus and personnel are in clos

16、e proximity to the fire combined with the additional exposure to hazards caused by a vehicle in motion. The personnel and/or apparatus could be subject to injury or damage due to accidental impact, rollover, and/or environmental hazards, including burn over. To mitigate the increased risk inherent w

17、ith pump-and-roll operations, the following tactics are recommended: (1) Driver is located inside the apparatus in a seated, belted position within the enclosed cab. Fire fighter(s) located outside the cab, walking alongside the apparatus, in clear view of the driver, discharging water with a short

18、hose line. (2) Driver and fire fighter(s) are located inside the apparatus in a seated, belted position within the enclosed cab. Water is discharged via a monitor or turret that is controlled from within the apparatus. (3) Driver is located inside the apparatus in a seated, belted position within th

19、e enclosed cab with one or more fire fighters seated and belted in the on-board pump-and-roll fire-fighting position as specified in Section 14.4. (4) Driver and fire fighter(s) are located inside the apparatus in a seated, belted position within the enclosed cab, but water is discharged with a shor

20、t hose line or hard line out an open cab window. (5) And under no circumstances is it ever considered safe practice to ride standing or seated on the exterior of the apparatus for mobile attack other than seated and belted in an on-board pump-and-roll fire-fighting position. (See Section 6.3 of NFPA

21、 1500.) The on-board pump-and-roll fire-fighting position should only be used when the following conditions are met: (1) The apparatus is actively engaged in mobile attack on the fire line. (2) The fuel model is characterized as fine fuels. (3) The ground is level, flat, and free of obstacles. (4) D

22、river visibility is unobstructed. (5) Vehicle speeds are no greater than 10 mph. (6) Fire fighter is wearing full protective NFPA 1977-compliant personal protective equipment and is equipped with a fire shelter. A.14.4.3.4 This is to protect against objects such as limbs entering the seating enclosu

23、re. Woven wire cloth with in. (0.6 cm) diameter wire spaced at 1 in. (4.4 cm) on centers is commonly used in the forestry industry to provide this protection. 4. Add new A.14.1.1 to read as follows: A.14.1.1 Typically, while engaged in fire-fighting operations on structural fires, apparatus are posi

24、tioned in a safe location, and hose is extended as necessary to discharge water or suppressants on the combustible material. In wildland fire suppression, mobile attack is often utilized in addition to stationary pumping. In mobile attack, sometimes referred to as “pump-and-roll,” water is discharge

25、d from the apparatus while the vehicle is in motion. Pump-and-roll operations are inherently more dangerous than stationary pumping because the apparatus and personnel are in close proximity to the fire combined with the additional exposure to hazards caused by a vehicle in motion, often on uneven g

26、round. The personnel and/or apparatus could thus be more easily subject to injury or damage due to accidental impact, rollover, and/or environmental hazards, including burn over. To potentially mitigate against the increased risk inherent with pump-and-roll operations, the following alternatives are

27、 provided for consideration: (1) Driver and fire fighter(s) are located inside the apparatus in a seated, belted position within the enclosed cab. Water is discharged via a monitor or turret that is controlled from within the apparatus. (2) Driver and fire fighter(s) are located inside the apparatus

28、 in a seated, belted position within the enclosed cab, but water is discharged with a short hose line or hard line out an open cab window. (3) Driver is located inside the apparatus in a seated, belted position within the enclosed cab with one or more fire fighters seated and belted in the on-board

29、pump-and-roll fire-fighting position as described in a following section. (4) Driver is located inside the apparatus in a seated, belted position within the enclosed cab. Fire fighter(s) is located outside the cab, walking alongside the apparatus, in clear view of the driver, discharging water with

30、a short hose line. Under no circumstances is it ever considered a safe practice to ride standing or seated on the exterior of the apparatus for mobile attack other than seated and belted in an on-board pump-and-roll fire-fighting position. The on-board pump-and-roll fire-fighting position should onl

31、y be used when the following conditions are met: (1) The apparatus is actively engaged in mobile attack on the fire line (2) The fuel model is characterized as fine fuels (3) The ground is level, flat, and free of obstacles (4) Driver visibility is unobstructed (5) Vehicle speeds are no greater than

32、 10 mph and (6) Fire fighter is wearing full protective NFPA 1977-compliant personal protective equipment and is equipped with a fire shelter On-Board Pump-and-Roll Fire-Fighting Position. If an on-board pump-and-roll fire-fighting position as described as follows is provided, it should only be on a

33、 wildland fire apparatus with a GVWR of no more than 19,500 lb. If an on-board pump-and-roll fire-fighting position is provided, it should, at minimum, include the following safety-related attributes: (1) A seat with an approved Type 1 seat belt for each fire- fighting position (2) Controls required

34、 by the operator within reach without removing the seat belt (3) A means of communication with the driver (4) One safety sign warning of the hazards of this riding position that is substantially similar to FAMA44, which warns of riding safety procedures, and the maximum speed of 10 mph visible from

35、the pump-and-roll fire-fighting position and (5) Safety sign FAMA45, which warns of driving safety procedures, and the maximum speed of 10 mph visible from the drivers position or visible to the driver while entering the cab If the seating position is located outside the cab, it should also meet the

36、 following requirements: (1) The seating position should be located behind the cab and ahead of the rear axle (2) A protective structure should be provided in compliance with the side impact and crush criteria from SAE J1194, Rollover Protective Structures (ROPS) for Wheeled Agricultural Tractors (3

37、) The protective structure should be designed to allow exit from either side of the vehicle (4) The protective structure should include a perforated plate or mesh with openings no larger than 1.5 in. (3.8 cm) 1.5 in. (3.8 cm) or other solid guard to protect from brush hazards at the front, the back,

38、 and the roof. This is to protect against objects such as limbs entering the seating enclosure. Woven wire cloth with in. (0.6 cm) diameter wire spaced at 1 in. (4.4 cm) on centers is commonly used in the forestry industry to provide this protection and (5) A door or gate with a latching mechanism s

39、hould be provided on each side of the vehicle designed to allow exit out of either side of the vehicle. a. The door or gate should be designed to prevent outward swing even in the event of failure of the latching mechanism b. The door or gate should be at least 48 in. (1200 mm) high from the walking

40、 surface below the fire-fighters feet and c. The door or gate should be constructed so there are no horizontal or vertical openings below the 48 in. (1200 mm) minimum height greater than 24 in. (610 mm) in either direction. Equipment located within the seating enclosure position protective structure

41、 should meet the requirements of 14.1.10. Development of this Design. Fire-fighting is an inherently dangerous operation. This is especially true of fighting a moving wildland fire in fine fuels. There are many techniques used and a great deal of discussion about the safest way to fight these fires.

42、 Over the years, many fire companies and apparatus manufacturers have developed techniques and equipment for fighting wildland fine-fuel fires. These have included fighting fire from seats mounted to front bumpers, sitting on hoods or hose reels, standing on flat beds, standing in step wells on the

43、side of apparatus, standing on running boards, or walking alongside a moving apparatus. All of these approaches are extremely dangerous. The Fire Department Apparatus Committee did extensive work to try to come up with a safer solution. We looked at the available apparatus and techniques that have b

44、een historically used in the industry. The preceding suggestions are safer than any of these ad-hoc techniques. The Fire Service Occupational Safety and Health Committee (NFPA 1500) does not approve of any fireground operations that permit the fire-fighter to ride outside the fully enclosed cab of a

45、 moving apparatus. 5. Add new entry to E.1.2.4 to read as follows: E.1.2.4 SAE Publications. Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096-0001 SAE J1194, Rollover Protective Structures (ROPS) for Wheeled Agriculture Tractors, 2016. Issue Date: August 17, 2017 Effective Date: September 6, 2017 (Note: For further information on NFPA Codes and Standards, please see www.nfpa.org/docinfo) Copyright 2017 All Rights Reserved NATIONAL FIRE PROTECTION ASSOCIATION

展开阅读全文
相关资源
猜你喜欢
  • DIN EN ISO 6647-1-2015 Rice - Determination of amylose content - Part 1 Reference method (ISO 6647-1 2015) German version EN ISO 6647-1 2015《稻米 直链淀粉含量测定 第1部分 基准方法(ISO 6647-1-2015) .pdf DIN EN ISO 6647-1-2015 Rice - Determination of amylose content - Part 1 Reference method (ISO 6647-1 2015) German version EN ISO 6647-1 2015《稻米 直链淀粉含量测定 第1部分 基准方法(ISO 6647-1-2015) .pdf
  • DIN EN ISO 6647-2-2015 Rice - Determination of amylose content - Part 2 Routine methods (ISO 6647-2 2015) German version EN ISO 6647-2 2015《稻米 直链淀粉含量测定 第2部分 常规方法(ISO 6647-2-2015) 德.pdf DIN EN ISO 6647-2-2015 Rice - Determination of amylose content - Part 2 Routine methods (ISO 6647-2 2015) German version EN ISO 6647-2 2015《稻米 直链淀粉含量测定 第2部分 常规方法(ISO 6647-2-2015) 德.pdf
  • DIN EN ISO 665-2001 Oilseeds - Determination of moisture and volatile matter content (ISO 665 2000) German version EN ISO 665 2000《油料种子 水份和挥发性物质含量的测定》.pdf DIN EN ISO 665-2001 Oilseeds - Determination of moisture and volatile matter content (ISO 665 2000) German version EN ISO 665 2000《油料种子 水份和挥发性物质含量的测定》.pdf
  • DIN EN ISO 6682-2009 Earth moving machinery - Zones of comfort and reach for controls (ISO 6682 1986 including Amendment 1 1989) English version of DIN EN ISO 6682 2009-06《土方机械 控制装.pdf DIN EN ISO 6682-2009 Earth moving machinery - Zones of comfort and reach for controls (ISO 6682 1986 including Amendment 1 1989) English version of DIN EN ISO 6682 2009-06《土方机械 控制装.pdf
  • DIN EN ISO 6683-2009 Earth-moving machinery - Seat belts and seat belt anchorages - Performance requirements and tests (ISO 6683 2005) English version of DIN EN ISO 6683 2009-04《土方.pdf DIN EN ISO 6683-2009 Earth-moving machinery - Seat belts and seat belt anchorages - Performance requirements and tests (ISO 6683 2005) English version of DIN EN ISO 6683 2009-04《土方.pdf
  • DIN EN ISO 669-2016 Resistance welding - Resistance welding equipment - Mechanical and electrical requirements (ISO 669 2016) German version EN ISO 669 2016《阻焊 阻焊设备 机械和电气要求(ISO 669.pdf DIN EN ISO 669-2016 Resistance welding - Resistance welding equipment - Mechanical and electrical requirements (ISO 669 2016) German version EN ISO 669 2016《阻焊 阻焊设备 机械和电气要求(ISO 669.pdf
  • DIN EN ISO 6708-1995 Pipework components - Definition and selection of DN (nominal size) (ISO 6708 1995) German version EN ISO 6708 1995《管件 DN(公称尺寸)的定义和选择 (ISO 6708 1995) 德文版本 EN I.pdf DIN EN ISO 6708-1995 Pipework components - Definition and selection of DN (nominal size) (ISO 6708 1995) German version EN ISO 6708 1995《管件 DN(公称尺寸)的定义和选择 (ISO 6708 1995) 德文版本 EN I.pdf
  • DIN EN ISO 6709-2009 Standard representation of geographic point location by coordinates (ISO 6709 2008 including Cor 1 2009) English version of DIN EN ISO 6709 2009-10《地理坐标点位置的标准表.pdf DIN EN ISO 6709-2009 Standard representation of geographic point location by coordinates (ISO 6709 2008 including Cor 1 2009) English version of DIN EN ISO 6709 2009-10《地理坐标点位置的标准表.pdf
  • DIN EN ISO 6719-2011 Anodizing of aluminium and its alloys - Measurement of reflectance characteristics of aluminium surfaces using integrating-sphere instruments (ISO 6719 2010) G.pdf DIN EN ISO 6719-2011 Anodizing of aluminium and its alloys - Measurement of reflectance characteristics of aluminium surfaces using integrating-sphere instruments (ISO 6719 2010) G.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1