1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a

2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): ELEVStandard Number: UL 817Standard Title: Standard for Cord Sets and Power-Supply CordsEdition Date: March 11, 2015Edition Number: 12Section / Paragraph Ref

3、erence: Table SA3.1Subject: Ampacity rating for an 18 and 17 AWG seasonal-use cord setDECISION:Table SA3.1Flexible cord and overcurrent protection for seasonal-use cord setsWire size Wire type Maximum overcurrent protectorrating (A)AWG (mm2)18 (0.824) SP-2, SPT-2, SPE-2, SV, SVO, SVOO,SVT, SVTO, SVT

4、OO, SVE5817 (1.0) SV, SVO, SVOO, SVT, SVTO, SVTOO,SVE8916 (1.3) SP-2, SPT-2, SPE-2 10RATIONALE FOR DECISION:The ampacity rating for an 18 AWG flexible cord in UL 588, The Standard for Seasonal and HolidayDecorative Products has been revised to allow a maximum rating of 8 amperes. Therefore, we are a

5、lsorevising the ampacity rating for a seasonal use cord set accordingly. At the same time we are increasingthe ampacity rating of 17 AWG to 9 amps which is within the allowable limited for a 17 AWG cord per theNEC.Copyright 2015 Underwriters Laboratories Inc.UL, in performing its functions in accord

6、ance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of Underwriters Laboratories Inc. inpractically applying the requirement

7、s of the standard. They do not represent formal interpretations of thestandard under American National Standards Institute (ANSI) processes. UL shall not be responsible toanyone for the use of or reliance upon Certification Requirement Decisions by anyone. UL shall not incurany obligation or liabili

8、ty for damages, including consequential damages, arising out of or in connectionwith the use or reliance upon Certification Requirement Decisions. The electronic version of theCertification Requirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSTANDARD NUMBER: UL 817 -2-No Text on This Page