GA 234-2008 CONTROL JOINTS FOR FIRE-RESISTANCE RATED SYSTEMS《防火分级系统用控制接头》.pdf

上传人:sofeeling205 文档编号:1228972 上传时间:2019-08-11 格式:PDF 页数:2 大小:241.64KB
下载 相关 举报
GA 234-2008 CONTROL JOINTS FOR FIRE-RESISTANCE RATED SYSTEMS《防火分级系统用控制接头》.pdf_第1页
第1页 / 共2页
GA 234-2008 CONTROL JOINTS FOR FIRE-RESISTANCE RATED SYSTEMS《防火分级系统用控制接头》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、GA-234-08 Copyright 2008 Gypsum Association. All right reserved. Printed in U.S.A. GYPSUM ASSOCIATION 810 FIRST STREET NE, #510 WASHINGTON, DC 20002 CONTROL JOINTS FOR FIRE-RESISTANCE RATED SYSTEMS (GA-234-08)Control joints in gypsum panel product systems shall be installed where indicated on the pl

2、ans or specifications. Gypsum Association recommended specifications and manufacturers recommendations specify minimum requirements for the installation of control joints. Control joints in the gypsum board systems shall be specified by the architect or designer where any of the conditions listed be

3、low exist. 1. A partition, wall, or ceiling traverses a construction joint (expansion, seismic, or building control element) in the base building structure. 2. Where a wall or partition runs in an uninterrupted straight plane exceeding 30 ft (9 m) in length and total area between control joints does

4、 not exceed 900 ft2(81 m2). NOTE: Full height door frames may be considered a control joint. 3. Interior Ceilings With Perimeter Relief: Control joints shall be installed so that linear dimensions between control joints shall not exceed 50 ft (15 m) and total area between control joints does not exc

5、eed 2500 ft2(225 m2). 4. Interior Ceilings Without Perimeter Relief: Control joints shall be installed so that linear dimensions between control joints shall not exceed 30 ft (9 m) and total area between control joints does not exceed 900 ft2(81 m2). 5. Exterior Ceilings and Soffits: Control joints

6、shall be installed so that linear dimensions between control joints shall not exceed 30 ft (9 m) and total area between control joints does not exceed 900 ft2(81 m2). 6. A control joint or intermediate blocking shall be installed where ceiling framing members change direction. 7. A control joint is

7、desired or incorporated as a design accent or architectural feature. The methods shown for protecting control joints in 1-hour floor-ceiling systems, either direct-attached, furred, or suspended, are applicable to all 1-hour floor ceiling systems with either wood or metal framing including, but not

8、limited to, dimension lumber, wood trusses, wood I- beams, steel bar joists, and steel channel joists. Individual gypsum board strips applied behind control joints in ceiling systems shall be not less than the shorter of 48 in. (1200 mm) or the length of the control joint. 1-HOUR NONCOMBUSTIBLE (WHI

9、647-3024, 9-20-90) This document may be revised or withdrawn from circulation at any time. The status of the document should be verified by the user prior to following any recommendations contained herein. To verify that you have the most current edition of the document, access the Gypsum Associati

10、on website at: www.gypsum.org. 1-HOUR WALL & PARTITION SYSTEMS 1-HOUR WOOD FRAMED (WHI-647-3024, 9-20-90) GA-234-08 Copyright 2008 Gypsum Association. All right reserved. Printed in U.S.A. 2-HOUR WALL & PARTITION SYSTEMS 2-HOUR NONCOMBUSTIBLE (WHI-651-0318.1, 3-20-90) 1-HOUR FLOOR-CEILING SYSTEM WIT

11、H SUSPENDED CEILING (UL R4024, 96NK13566, 7-29-96) 2-HOUR WOOD FRAMED (WHI-647-3024, 9-20-90) 1-HOUR WOOD FRAMED FLOOR-CEILING SYSTEMS CONTROL JOINT PARALLEL TO FRAMING WITH DIRECT-ATTACHED CEILING (UL R4024, 97NK13566, 7-29-96) CONTROL JOINT PARALLEL TO FRAMING WITH FURRED CEILING (UL R4024, 97NK2136, 2-7-97) CONTROL JOINT PERPENDICULAR TO FRAMING WITH FURRED CEILING (UL R4024, 96NK13566, 7-29-96)

展开阅读全文
相关资源
猜你喜欢
  • GOST R ISO 14644-8-2014 Cleanrooms and associated controlled environments Part 8 Classification of air cleanliness by chemical concentration《洁净室和相关控制环境 第8部分 采用化学浓度法对空气清洁度的分类》.pdf GOST R ISO 14644-8-2014 Cleanrooms and associated controlled environments Part 8 Classification of air cleanliness by chemical concentration《洁净室和相关控制环境 第8部分 采用化学浓度法对空气清洁度的分类》.pdf
  • GOST R ISO 14644-9-2013 Cleanrooms and associated controlled environments Part 9 Classification of surface cleanliness by particle concentration《洁净室和相关控制环境 第9部分 采用颗粒浓度法对洁净度的分类》.pdf GOST R ISO 14644-9-2013 Cleanrooms and associated controlled environments Part 9 Classification of surface cleanliness by particle concentration《洁净室和相关控制环境 第9部分 采用颗粒浓度法对洁净度的分类》.pdf
  • GOST R ISO 14687-1-2012 Hydrogen fuel Product specification Part 1 All applications except proton exchange membrane (PEM) fuel cell for road vehicles《氢燃料 产品规格 第1部分 道路车辆除质子交换膜(PEM)燃.pdf GOST R ISO 14687-1-2012 Hydrogen fuel Product specification Part 1 All applications except proton exchange membrane (PEM) fuel cell for road vehicles《氢燃料 产品规格 第1部分 道路车辆除质子交换膜(PEM)燃.pdf
  • GOST R ISO 14708-1-2012 Implants for surgery Active implantable medical devices Part 1 General requirements for safety marking and information to be provided by the manufacturer《外科.pdf GOST R ISO 14708-1-2012 Implants for surgery Active implantable medical devices Part 1 General requirements for safety marking and information to be provided by the manufacturer《外科.pdf
  • GOST R ISO 1472-1993 Textile machinery and accessories Cylindrical tubes for draw-twisters Dimensions and permissible run-out《纺织机械和配件 拉伸加捻机的圆柱形管 尺寸及可允许偏差》.pdf GOST R ISO 1472-1993 Textile machinery and accessories Cylindrical tubes for draw-twisters Dimensions and permissible run-out《纺织机械和配件 拉伸加捻机的圆柱形管 尺寸及可允许偏差》.pdf
  • GOST R ISO 1479-2013 Hexagon head tapping screws《六角头自攻螺钉》.pdf GOST R ISO 1479-2013 Hexagon head tapping screws《六角头自攻螺钉》.pdf
  • GOST R ISO 148-1-2013 Metallic materials Charpy pendulum impact test Part 1 Test method《金属材料 夏比摆锤冲击试验 第1部分 试验方法》.pdf GOST R ISO 148-1-2013 Metallic materials Charpy pendulum impact test Part 1 Test method《金属材料 夏比摆锤冲击试验 第1部分 试验方法》.pdf
  • GOST R ISO 14801-2012 Dentistry Implants Dynamic fatigue tests for endosseous dental implants《牙科学 植入物 骨质牙科植入物的动态疲劳试验》.pdf GOST R ISO 14801-2012 Dentistry Implants Dynamic fatigue tests for endosseous dental implants《牙科学 植入物 骨质牙科植入物的动态疲劳试验》.pdf
  • GOST R ISO 1481-2013 Slotted pan head tapping screws《开槽盘头自攻螺钉》.pdf GOST R ISO 1481-2013 Slotted pan head tapping screws《开槽盘头自攻螺钉》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 行业标准 > GA公共安全

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1