1、BSI Standards Publication Alarm systems Intrusion and hold-up systems Part 2-10: Intrusion detectors Lock state contacts (magnetic) PD CLC/TS 50131-2-10:2014National foreword This Published Document is the UK implementation of CLC/TS 50131-2-10:2014. The UK participation in its preparation was entru
2、sted by Technical Committee GW/1, Electronic security systems, to Subcommittee GW/1/1, Alarm components. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users a
3、re responsible for its correct application. The British Standards Institution 2014. Published by BSI Standards Limited 2014 ISBN 978 0 580 82745 7 ICS 13.320 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the authority of
4、 the Standards Policy and Strategy Committee on 31 May 2014. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD CLC/TS 50131-2-10:2014 TECHNICAL SPECIFICATION CLC/TS 50131-2-10 SPCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION January 2014 CENELEC European Committe
5、e for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CEN
6、ELEC members. Ref. No. CLC/TS 50131-2-10:2014 E ICS 13.320 English version Alarm systems - Intrusion and hold-up systems - Part 2-10: Intrusion detectors - Lock state contacts (magnetic) Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 2-10: Dtecteurs dintrusion - Contact
7、dtat de verrouillage (magntique) Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 2-10: Einbruchmelder - Verschluss- und ffnungsberwachungskontakte (magnetisch) This Technical Specification was approved by CENELEC on 2013-12-02. CENELEC members are required to announce the existence of this T
8、S in the same way as for an EN and to make the TS available promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Rep
9、ublic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
10、 PD CLC/TS 50131-2-10:2014CLC/TS 50131-2-10:2014 2 Contents Page Foreword . 4 Introduction . 5 1 Scope 6 2 Normative references 6 3 Terms, definitions and abbreviations 7 3.1 Terms and definitions . 7 3.2 Abbreviations . 8 4 Functional requirements. 9 4.1 Events . 9 4.2 Signals or messages . 9 4.3 D
11、etection 10 4.4 Operational requirements . 11 4.5 Tamper security . 11 4.6 Electrical requirements . 13 4.7 Environmental classification and conditions . 14 5 Marking, identification and documentation 15 5.1 Marking and/or identification . 15 5.2 Documentation 15 6 Testing 15 6.1 Generalities 15 6.2
12、 General test conditions. 15 6.3 Basic test of detection capability 16 6.4 Verification of detection performance . 16 6.5 Switch-on delay, time interval between signals, and indication of detection . 17 6.6 Tamper security . 17 6.7 Electrical tests . 19 6.8 Environmental classification and condition
13、s . 20 6.9 Marking, identification and documentation 22 Annex A (normative) Dimensions EN 50131-2-3, Alarm systems Intrusion and hold-up systems Part 2-3: Requirements for microwave detectors; EN 50131-2-4, Alarm systems Intrusion and hold-up systems Part 2-4: Requirements for combined passive infra
14、red and microwave detectors; EN 50131-2-5, Alarm systems Intrusion and hold-up systems Part 2-5: Requirements for combined passive infrared and ultrasonic detectors; EN 50131-2-6, Alarm systems Intrusion and hold-up systems Part 2-6: Opening contacts (magnetic); CLC/TS 50131-2-8, Alarm systems Intru
15、sion and hold-up systems Part 2-8: Intrusion detectors Shock detectors; CLC/FprTS 50131-2-9, Alarm systems Intrusion and hold-up systems Part 2-9: Intrusion detectors Active infrared beam detectors; CLC/TS 50131-2-10, Alarm systems Intrusion and hold-up systems Part 2-10: Intrusion detectors Lock st
16、ate contacts (magnetic) the present document; EN 50131-2-7-1, Alarm systems Intrusion and hold-up systems Part 2-7-1: Intrusion detectors Glass break detectors (acoustic); EN 50131-2-7-2, Alarm systems Intrusion and hold-up systems Part 2-7-2: Intrusion detectors Glass break detectors (passive); EN
17、50131-2-7-3, Alarm systems Intrusion and hold-up systems Part 2-7-3: Intrusion detectors Glass break detectors (active). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identify
18、ing any or all such patent rights. PD CLC/TS 50131-2-10:2014CLC/TS 50131-2-10:2014 5 Introduction This Technical Specification applies to lock state contacts (magnetic) used as part of intrusion and hold-up alarm systems (I BTD Basic Test of Detection capability; PD CLC/TS 50131-2-10:2014CLC/TS 5013
19、1-2-10:2014 9 DC Direct Current; EMC Electromagnetic Compatibility; RFID Radio Frequency Identification. 4 Functional requirements 4.1 Events The detector shall respond to events in accordance with Table 1 and as defined in this Clause 4. Table 1 Events to be processed and main functions to be provi
20、ded by grade Event to be processed and functions to be provided Grade 1 2 3 4 Break distance exceeded M M M M Inside make distance M M M M Remote enable of detection indication aOp Op M M Connecting field interference Op Op M M Prevention and detection of access to the inside of the detector OpbMcMc
21、McRemoval from the mounting surfacedOp M M M Low power supply voltageeOp Op M M Total loss of external powerfM M M M Matched pairs, coding and encryptionOp Op M gM gKey M = Mandatory Op = Optional a Only required if detection indicator present. b Generation of a tamper signal for opening by normal m
22、eans is not required. c Not required for sealed lock state contacts according to 4.5.2. d Mandatory for wire-free at grades 2, 3 and 4; mandatory for all grade 4 types, optional for wired grades 1, 2 and 3. e See 4.6.7. f See 4.6.6. g See 4.5.5. 4.2 Signals or messages The response to the signals or
23、 messages generated by the detector is determined by the I&HAS. The detector shall generate signals or messages in accordance with Table 2, based on the events listed in Table 1. Signals or messages shall be generated within 10 s of the event occurring. The response of a detector to events defined as optional in Table 1 shall be in accordance with Table 2. PD CLC/TS 50131-2-10:2014