AIR FORCE MIL-DTL-5500 F-2013 CAP HIGH PRESSURE AIR VALVE.pdf

上传人:boatfragile160 文档编号:427744 上传时间:2018-11-07 格式:PDF 页数:8 大小:51.15KB
下载 相关 举报
AIR FORCE MIL-DTL-5500 F-2013 CAP HIGH PRESSURE AIR VALVE.pdf_第1页
第1页 / 共8页
AIR FORCE MIL-DTL-5500 F-2013 CAP HIGH PRESSURE AIR VALVE.pdf_第2页
第2页 / 共8页
AIR FORCE MIL-DTL-5500 F-2013 CAP HIGH PRESSURE AIR VALVE.pdf_第3页
第3页 / 共8页
AIR FORCE MIL-DTL-5500 F-2013 CAP HIGH PRESSURE AIR VALVE.pdf_第4页
第4页 / 共8页
AIR FORCE MIL-DTL-5500 F-2013 CAP HIGH PRESSURE AIR VALVE.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 1650 MIL-DTL-5500F 31 July 2013 SUPERSEDING MIL-DTL-5500E 05 November 2007 DETAIL SPECIFICATION CAP, HIGH PRESSURE AIR VALVE This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type and gr

2、ade of high-pressure air valve cap suitable for use in aircraft hydraulic systems. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specificati

3、on or recommended for additional information or as examples. While every effort has been made to ensure the completeness of these lists, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they ar

4、e listed. 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to

5、ensure the completeness of these lists, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. INCH-POUND Comments, suggestions, or questions on this document should be addressed to

6、Oklahoma City Air Logistics Center/ENSDAA, 3001 Staff Drive, Suite 1AB81A, Tinker AFB, OK 73145 or emailed to tinker.dsptinker.af.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.mil. Prov

7、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-5500F 2 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards and handbooks form a part of this document to the extent specified herein. U

8、nless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-5606 - Hydraulic Fluid, Petroleum Base; Aircraft, Missile, and Ordnance MIL-PRF-6164 - Valve; Aircraft, Pneumatic, High-Pressure Charging MIL-PRF-685

9、5 - Rubber, Synthetic, Sheets, Strips, Molded or Extruded Shapes, General Specification For DEPARTMENT OF DEFENSE STANDARDS MIL-STD-130 - Identification Marking of U.S. Military Property MS20813 - Cap, Pneumatic Valve, High-Pressure (Copies of these documents are available online at https:/assist.dl

10、a.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these doc

11、uments are those cited in the solicitation or contract. AMERICAN SOCIETY FOR QUALITY (ASQ) ANSI/ASQ Z1.4 - Sampling Procedures and Tables for Inspection by Attributes (ASQ documents may be obtained online at http:/www.asq.org or from American Society for Quality, P.O. Box 3005, Milwaukee, WI 53201-3

12、005 or 600 North Plankinton Avenue, Milwaukee, WI 53203, USA.) 2.4 Order of Precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document

13、, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Qualification. The high pressure air valve cap furnished under this specification shall be products that are authorized by the qualifying activity for listing on the applicable qu

14、alified products list before contract award (see 4.3 and 6.4). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-5500F 3 3.2 Materials. Materials shall conform to applicable specifications as specified herein. 3.3 Design and construction. The c

15、ap shall be designed and constructed in accordance with MS20813. 3.3.1 Size and dimensions. The cap shall have dimensions conforming to MS20813. No part of the cap shall project outside the overall dimension indicated. 3.3.1.1 Valve stem. The cap shall fit with MIL-PRF-6164 valve stem. 3.3.2 Shell a

16、nd swivel seat plate. Material used in the shell and swivel seat plate shall be as specified in MS20813. 3.3.3 Seat. The valve seat material shall be in accordance with MIL-R-6855, class 2, type A, grade 60 or 80, or approved equivalent, that is resistant to hydraulic oil, conforming to MIL-PRF-5606

17、 and shall be suitably bonded to the swivel seat to withstand service usage without separation of the bond. 3.3.3.1 Resistant. The material shall be resistant to abrasion to prevent disintegration under pull-up tests or during normal service usage. 3.3.3.2 Compression resistant. The material shall h

18、ave suitable compression set resistance and flexibility at all operating temperatures between -65 to 160F (-54 to 71C) to seal all operating pressures up to 5,000 psi with maximum wrench torque of 30 inch-pounds. 3.3.3.3 Homogeneous. The material shall be homogeneous to insure consistent swell, stre

19、ngth, and hardness characteristics throughout the entire batch. 3.3.3.4 Physical properties. When subjected to accelerated aging in either air or hydraulic oil, referencing MIL-PRF-5606 for guidance, the tensile strength, elongation, and hardness characteristics of material shall not change more tha

20、n the values indicated in TABLE I. TABLE I. Seat material physical properties. PROPERTY CHANGE INCREASE (MAX) PERCENT DECREASE (MAX) Tensile strength - 20 Elongation - 30 Hardness shore durometer 10 10 3.3.4 Finish. Finish shall be as specified in MS20813. The swivel seat need not be finished. 3.3.5

21、 Assembly. The bonded valve seat assembly shall swivel freely in the housing after assembly, but shall not fall out during normal service handling or usage. 3.4 Proof and burst pressures. Caps shall withstand a proof pressure of 10,000 psi and a Provided by IHSNot for ResaleNo reproduction or networ

22、king permitted without license from IHS-,-,-MIL-DTL-5500F 4 burst pressure of 20,000 psi. 3.5 Pull-up. The caps shall withstand 30 pull-ups at a wrench torque of 50 inch-pounds. Ten of these pull-ups shall be after the caps have been exposed a minimum of 72 hours to a temperature of -65F (-54C). 3.6

23、 Impulse. During the impulse test there shall be no leakage in excess of 1 drop per 10,000 cycles at room temperature or 1 drop per 1,000 cycles at -65F (-54C). 3.7 Leakage. The cap shall not leak or malfunction in any manner at all operating conditions up to the design operating pressure of 5,000 p

24、si at a wrench tightening torque of 15 to 50 inches-pound when seated on an MIL-PRF-6164 valve stem. 3.8 Identification of product. Each cap shall be permanently marked for identification with the part number and the manufacturers name, symbol, or trade-mark in accordance with MIL-STD-130. This mark

25、ing shall be placed in the recessed diameter as shown on MS20813. 3.9 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational

26、and maintenance requirements, and promotes economically advantageous life cycle costs. 4. VERIFICATION 4.1 Classification of inspections. The inspection requirements specified herein are classified as follows: a. Qualification inspection (see 4.3). b. Conformance inspection (see 4.5). 4.2 Inspection

27、 conditions. Unless otherwise specified, all tests required by this specification shall be made at an atmospheric pressure of approximately 29.92 inches of Hg and a temperature of 77 F. When tests are made with ambient pressure or temperature substantially different from the above values, proper all

28、owance shall be made for the difference from the specified conditions. 4.2.1 Sampling instructions. Qualification test samples shall consist of 12 caps, 144 square inches of 0.125 inch thick platen press sheets of the seat material compounded as in the production seat and given an equivalent cure, a

29、nd detail and assembly drawings. Identify samples as required. 4.2.2 Preparation of valve caps for qualification inspection. Three caps to be subjected to qualification tests shall be air-aged in a Geer oven, or equivalent, at 1582F (701C) for 7 days, and a second group of 3 shall be aged in hydraul

30、ic fluid conforming to MIL-PRF-5606 and held at a temperature of 1582F (701C) in a closed container or reflux condenser for 7 days. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-5500F 5 4.3 Qualification inspections. The qualification tests

31、 of the caps shall consist of all the tests specified under Conformance inspections and, in addition, the following tests: 4.3.1 Seat material. The seat material shall be tested in accordance with MIL-PRF-6855. 4.3.2 Burst pressure. The caps, when seated in a body conforming to MIL-PRF-6164 shall wi

32、thstand a burst pressure up to 20,000 psi, without failure, distortion, or evidence of leakage in any manner. 4.3.3 Pull-up. Three new caps and the 3 caps aged in air and hydraulic oil, shall be assembled and disassembled on an MIL-PRF-6164 valve, reference MIL-PRF-6164 at least 30 times at a wrench

33、 torque of 50 inch-pounds minimum. Each assembly and disassembly shall consist of a complete tightening to the specified torque and then loosened until the seat has ceased making contact with the valve body. 4.3.3.1 Cold-soak pull-up. At least 10 of these pull-ups shall be made at a temperature not

34、warmer than -65F (-54C) after the caps have been exposed to this temperature for a minimum of 72 hours. During this cold-soaking period, the caps shall not be tightened on the bodies. 4.3.4 Impulse. The same caps as used in the pull-up test shall be installed on an MIL-PRF-6164 valve and impulse cyc

35、led from 0 to 1,500 psi pressure at the pace of 25 +10 cycles per minute for 50,000 impulses minimum. The impulse medium shall be hydraulic oil conforming to MIL-PRF-5606. At least 5,000 of these impulses shall be made with the impulse medium and the caps at a temperature not warmer than -65F (-54 C

36、). The caps shall be held at this temperature for 72 hours prior to the start of the -65F (-54 C) impulse cycles. Leakage shall not exceed the values specified (see 3.6). 4.3.5 Leakage. The caps used on the impulse test specified (see 4.3.4) shall be loosened and retightened on MIL-PRF-6164 valves w

37、ith 15 to 20 inch-pound torque. The caps shall be tested for 1 hour at 10 psi and for 1 hour at 5,000 psi. No leakage shall occur during the 1 hour test periods. 4.3.5.1 Caps. The caps, still on the bodies at the same torque, shall be chilled to at least -65F (-54C) for 24 hours while maintaining ai

38、r pressure of not less than 1,000 psi in the inside of the caps. No leakage shall occur. 4.3.5.2 Leakage check. Leakage may be checked by immersion under water or other transparent liquid or by securely fastening a deflated rubber bag on the valve body in such a manner that all leakage from the cap

39、would be trapped in the bag. 4.4 Examination after test. After completion of the tests enumerated herein, all the caps shall be examined for deterioration and failure. There shall be no separation of the seat from the swivel seat plate, and the swivel shall not be tightly jammed into the housing. Th

40、ere shall be no evidence of excessive wear or deterioration, such as flaking, cracking, or cutting of the seat Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-5500F 6 material. A compression set of the seat in the form of a circular groove at

41、 the contact point of the seat on the MIL-PRF-6164 stem and a slight roughening of the seat material, shall not be interpreted as excessive wear or deterioration. 4.5 Conformance inspections. The conformance inspections shall consist of individual tests and sampling tests. 4.5.1 Individual tests. Ea

42、ch cap shall be subjected to the following test: 4.5.1.1 Examination of product. Each cap shall be carefully examined to determine conformance with this specification with respect to dimensions, finish, material, and workmanship 4.5.2 Sampling tests. The caps shall be sampled in accordance with ANSI

43、/ASQ Z1.4 at the normal inspection level, unless otherwise specified in the acquisition document (see 6.2), and subjected to the proof pressure test as specified (see 4.5.2.1). In addition, these caps shall be subjected to any of the tests described under qualification tests which the inspector cons

44、iders necessary to determine conformance with the requirements of this specification. 4.5.2.1 Proof pressure. The cap seated on a body conforming to MIL-PRF-6164 shall be subjected to a proof pressure of up to 10,000 psi without failure, distortion, or evidence of leakage in any manner. 4.5.3 Reject

45、ion and retest. When an item selected from a production run fails to meet the specification, no items still on hand or later produced shall be accepted until the extent and cause of failure have been determined and appropriately corrected. The contractor shall explain to the Government representativ

46、e the cause of failure and the action taken to preclude recurrence. After correction, all of the tests shall be repeated. 4.5.3.1 Individual tests may continue. For production reasons, individual tests or other sampling plans may be continued pending the investigation of a sampling test failure. But

47、 final acceptance of the items on hand or items produced later shall not be made until it is determined that all items meet all the requirements of the specification. 4.6 Retention of qualification. Each vendor listed on the Qualified Products List (QPL) shall be required to certify their product on

48、 DD form 1718 every 2 years. Contractor shall repeat the qualification requirements specified (see 4.3) under the following circumstances: a. Contractor has not manufactured the item for a period in excess of ten years. b. Contractor has relocated the facility in which the items were manufactured. 5

49、. PACKAGING 5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When packaging of materiel is to be performed by Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-5500F 7 DoD or in-house contractor personnel, these personnel need to contact the responsible pack

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1