1、A.1ASHRAE HANDBOOKAdditions and CorrectionsThis report includes additional information, and technical errorsfound between June 15, 2012, and April 1, 2015, in the inch-pound(I-P) editions of the 2012, 2013, and 2014 ASHRAE Handbookvolumes. Occasional typographical errors and nonstandard symbollabels

2、 will be corrected in future volumes. The most current list ofHandbook additions and corrections is on the ASHRAE web site(www.ashrae.org).The authors and editor encourage you to notify them if youfind other technical errors. Please send corrections to: HandbookEditor, ASHRAE, 1791 Tullie Circle NE,

3、 Atlanta, GA 30329, ore-mail mowenashrae.org.2012 HVAC Systems and Equipmentp. 25.1, Fig. 1. Point E was omitted. The correct figure appearsbelow.p. 26.2, Eq. (2a). In the rightmost fraction, change msto me.p. 26.12, Example 2. Flow rate for ethylene glycol should be ingpm.p. 26.12, Fig. 13. The cor

4、rected figure is given below.p. 41.3, Fig. 3. Replace parts B and C of the graphic with the hori-zontal polymer tube shown on p. A.2.p. 44.8, Table 1. In both equations for flow and head, change theminuses to equals signs.p. 51.24, Fig. 25. The bottom right line should have the dischargearrow pointi

5、ng to the left, and the charge arrow pointing to the right.The corrected figure is shown on p. A.2.2013 Fundamentalsp. 1.13, 2nd col. Above Eq. (38), change “td( p, w)” to “td( p, W ).”p. 1.14, 1st col. In the table for Situation 2, 3rd line, Comments col-umn, change “td” to “t.”p. 4.21, Solution fo

6、r Example 10, starting in 3rd para. Compute hiusing Eq. (T8.5a). Delete fsand its value. Nudshould be 248.3, andhishould be 1248 Btu/hft2F. Compute housing Eq. (T9.10a).Change Ra to 74 574, Nu to 7.223, hoto 3.643 Btu/hft2F, and theequation for hotto 0.643 + 0.757 = 1.400 Btu/hft2F. Change the lastp

7、aragraph in the example as follows:Solving for domakes the left side of Equation (42) equal to the rightside, and gives do= 1.576 in. Now, using the new value of 1.576 in. forthe outer diameter, the new values of hoand hotare 0.680 Btu/hft2Fand 1.437 Btu/hft2F, respectively. The updated value of doi

8、s 1.857 in.Repeating the process several times results in a final value of do= 1.733in. Thus, an outer diameter of 1.7874 in. (corresponding to an insula-tion radial thickness of 0.5 in.) keeps the outer surface temperature at75.4F, higher than the dew point. Another method is to use Equation(42) to

9、 solve for tofor values of docorresponding to available insulationthicknesses and using the insulation thickness that keeps toabove thedew-point temperature.p. 9.19, 1st col. For Eq. (71), remove the minus sign before “(tsk93.2).” In the following definitions, add that tbsetshould beFig. 1 Dehumidif

10、ication Process Points(2012 HVAC Systems and Equipment, Ch. 25, p. 1)Fig. 13 The Psychrometric Processes of Exchangers in Series Mode(Moffitt 2011)(2012 HVAC Systems and Equipment, Ch. 26, p. 12)A.2 20122014 ASHRAE Handbook Additions and Corrections97.68F. In Eq. (72), change the minus in the denomi

11、nator to aplus.Ch. 14, climate data table for Esbjerg, Denmark. Please use the2009 data for this location.p. 15.17, Eq. (13). The equals sign belongs after “SHGC().”p. 15.29, Example 6, Solution. The first equation should read qs=qb+ qd.p. 15.32, Eq. (40). Change “min(1,0.02 )” to “min(1.2,60)/60.”

12、Add Barnaby et al. (2009) to the list of sources cited below.p. 16.24, Table 8. The corrected table appears above.p. 16.24, Example 5. The houses flow coefficient c should be4370 cfm/(in. of water)n. In the Solution, Csshould be 0.001478 (in.of water)/Fnand Cwshould be 0.001313 (in. of water)/mphn.C

13、onsequently, the second and third equations should be as follows:Qs= 4370(0.001478)68 (2)0.67= 110 cfmQw= 4370(0.001313)(0.64 8.9)1.34= 59 cfmQ is thus 125 cfm = 7490 ft3/h, and the final equation should beI = (7490 ft3/h)/(12,000 ft3) = 0.62 achpp. 16.24-25, Example 6. The houses flow coefficient c

14、 should be6890 cfm/(in. of water)n. In the Solution, Csshould be 0.00893 (in.of water)/Fnand Cwshould be 0.001074 (in. of water)/mphn.Consequently, the second and third equations should be as follows:Qs= 6890(0.00893)(29)0.6= 46 cfmQw= 6890(0.001074)(0.50 2.9)1.34= 12 cfmQ is thus 48 cfm = 2880 ft3/

15、h, and the final equation should beI = (2880 ft3/h)/(9000 ft3) = 0.32 achp. 16.25, Example 7. The houses flow coefficient c should be8740 cfm/(in. of water)n. In the Solution, Csshould be 0.001791 (in.of water)/Fnand Cwshould be 0.001295 (in. of water)/mphn.Consequently, the second and third equatio

16、ns should be as follows:Qs= 8740(0.001791)(9)0.67= 68 cfmQw= 8740(0.001295)(0.43 6.7)1.34= 47 cfmQ is thus 83 cfm = 4960 ft3/h, and the final equation should beI = (4960 ft3/h)/(14,200 ft3) = 0.35 achp. 17.12-13, Fig. 1. The corrected figure is shown on p. A.3.p. 18.35, 2nd col. Just above the Plenu

17、ms in Load Calculations head-ing, the citation for the UFAD Design Guide should be ASHRAE(2013).p. 18.41, 1st col. In equation for q15, the last term on the first lineshould be c23qi,16.p. 18.49, References. Delete the Bauman and Daly 2013 source, andreplace it with the following:ASHRAE. 2013. Under

18、floor air distribution (UFAD) design guide, 2nd ed.p. 20.1, 1st col. Immediately after the bulleted list, change theparagraph as follows: “As shown in Figure 1, local temperatureconcentration has a similar profile, although its rate usually dif-fers. Carbon dioxide (CO2) follows a similar pattern.”p

19、p. 21.7-8. Renumber Figure 10 (Diffuser Installation Suggestions)as Figure 9, and Figure 9 (Friction Chart) as Figure 10.Table 8 Enhanced Model Stack and Wind Coefficients(2013 Fundamentals, Ch. 16, p. 24)One-Story Two-Story Three-StoryNo Flue With Flue No Flue With Flue No Flue With FlueCs0.000891

20、0.001144 0.001308 0.001478 0.001641 0.001791Cwfor basement slab 0.001313 0.001194 0.001432 0.001313 0.001432 0.001402Cwfor crawlspace 0.001074 0.001074 0.001194 0.001194 0.001271 0.001295Fig. 3 Indirect Evaporative Cooling (IEC) Heat Exchanger(Courtesy Munters/Des Champs)(2012 HVAC Systems and Equip

21、ment, Ch. 41, p. 3. Replaces only parts B and C of Fig. 3.)Fig. 25 Typical Sensible Storage Connection Scheme(2012 HVAC Systems and Equipment, Ch. 51, p. 24)20122014 ASHRAE Handbook Additions and Corrections A.3p. 21.21, 2nd col., 3rd para. from bottom. The reference to Figure16 should be to Figure

22、21, and the reference to Figure 10 should beto Figure 9.p. 21.22, step 9c. The correct section in ASHRAE Standard 90.1 is6.5.3.1.p. 22.2, 2nd col. Change “(Table 8 and Figure 7)” to “(Tables 6 and10).”p. 23.18, definitions for Eq. (8). The symbol for outer radius shouldbe r2; for inner radius, it should be r1.2014 Refrigerationp. 12.31, Fig. 68. The source for this graphic should be Seeton et al.2000.p. 24.6, definitions for Eq. (16). In the definition for qs/A, the ref-erence should be to Figure 9.Fig. 1 Example House(2013 Fundamentals, Ch. 17, p. 12)

展开阅读全文
相关资源
猜你喜欢
  • BS ISO 8640-3-2002 Textile machinery and accessories - Flat warp knitting machines - Vocabulary - Vocabulary of patterning devices《纺织机械和附件 平经针织机 词汇 提花装置词汇》.pdf BS ISO 8640-3-2002 Textile machinery and accessories - Flat warp knitting machines - Vocabulary - Vocabulary of patterning devices《纺织机械和附件 平经针织机 词汇 提花装置词汇》.pdf
  • BS ISO 8641-2008 Aerospace - Self-locking nuts with maximum operating temperature greater than 425 °C - Procurement specification《航空航天 最大工作温度大于425℃的自锁紧螺母 采购规范》.pdf BS ISO 8641-2008 Aerospace - Self-locking nuts with maximum operating temperature greater than 425 °C - Procurement specification《航空航天 最大工作温度大于425℃的自锁紧螺母 采购规范》.pdf
  • BS ISO 8642-2008 Aerospace - Self-locking nuts with maximum operating temperature greater than 425 degrees C Test methods《航空航天 工作温度高于425℃的自锁螺母 试验方法》.pdf BS ISO 8642-2008 Aerospace - Self-locking nuts with maximum operating temperature greater than 425 degrees C Test methods《航空航天 工作温度高于425℃的自锁螺母 试验方法》.pdf
  • BS ISO 8643-2017 Earth-moving machinery Hydraulic excavator and backhoe loader lowering control device Requirements and tests《土方机械 液压挖掘机和挖掘装载机动下降控制装置 要求和试验》.pdf BS ISO 8643-2017 Earth-moving machinery Hydraulic excavator and backhoe loader lowering control device Requirements and tests《土方机械 液压挖掘机和挖掘装载机动下降控制装置 要求和试验》.pdf
  • BS ISO 8660-2002 Plastics - Determination of permanganate absorption number of caprolactam - Spectrometric method《塑料 己内酰胺的高锰酸盐吸收指数的侧定 光谱分析法》.pdf BS ISO 8660-2002 Plastics - Determination of permanganate absorption number of caprolactam - Spectrometric method《塑料 己内酰胺的高锰酸盐吸收指数的侧定 光谱分析法》.pdf
  • BS ISO 8670-3-2000 Ostomy collection bags - Determination of odour transmission of colostomy and ileostomy bags《造口术收集袋 结肠造口术和回肠造口术收集袋的气味传递测定》.pdf BS ISO 8670-3-2000 Ostomy collection bags - Determination of odour transmission of colostomy and ileostomy bags《造口术收集袋 结肠造口术和回肠造口术收集袋的气味传递测定》.pdf
  • BS ISO 8693-2011 Tools for moulding Flat ejector pins《塑模工具 平压铸模零件》.pdf BS ISO 8693-2011 Tools for moulding Flat ejector pins《塑模工具 平压铸模零件》.pdf
  • BS ISO 8694-2011 Tools for moulding Shouldered ejector pins《塑模工具 带凸肩的压铸模零件》.pdf BS ISO 8694-2011 Tools for moulding Shouldered ejector pins《塑模工具 带凸肩的压铸模零件》.pdf
  • BS ISO 8695-2010 Tools for pressing - Punches - Nomenclature and terminology《冲压工具 冲压机 术语和命名法》.pdf BS ISO 8695-2010 Tools for pressing - Punches - Nomenclature and terminology《冲压工具 冲压机 术语和命名法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1