1、Designation: A252 10 (Reapproved 2018)Standard Specification forWelded and Seamless Steel Pipe Piles1This standard is issued under the fixed designation A252; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio

2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers nominal (average) wall steelpipe piles of cylindrical shape and applies to pipe piles inwhich the steel

3、cylinder acts as a permanent load-carryingmember, or as a shell to form cast-in-place concrete piles.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not cons

4、idered standard.1.3 The text of this specification contains notes and foot-notes that provide explanatory material. Such notes andfootnotes, excluding those in tables and figures, do not containany mandatory requirements.1.4 The following precautionary caveat pertains only to thetest method portion,

5、 Section 16 of this specification. Thisstandard does not purport to address all of the safety problems,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety, health, andenvironmental practices and determine the applicability ofregulator

6、y limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organi

7、zation TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2A370 Test Methods and Definitions for Mechanical Testingof Steel ProductsA751 Test Methods, Practices, and Terminology for Chemi-cal Analysis of Steel ProductsA941 Terminology Relating to Steel, Stainless St

8、eel, RelatedAlloys, and FerroalloysE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with Specifications3. Terminology3.1 Definitions:3.1.1 Definitions of terms used in this specification shall bein accordance with Terminology A941.3.1.2 defectan imperfection of sufficie

9、nt size or magnitudeto be cause for rejection.3.1.3 imperfectionany discontinuity or irregularity foundin the pipe.4. Ordering Information4.1 Orders for material under this specification shall containinformation concerning as many of the following items as arerequired to describe the desired materia

10、l adequately:4.1.1 Quantity (feet or number of lengths),4.1.2 Name of material (steel pipe piles),4.1.3 Method of manufacture (seamless or welded),4.1.4 Grade (Tables 1 and 2),4.1.5 Size (outside diameter and nominal wall thickness),4.1.6 Lengths (single random, double random, or uniform)(see Sectio

11、n 13),4.1.7 End finish (Section 15), and4.1.8 ASTM specification designation and year of issue,4.1.9 Location of purchasers inspection (see 19.1), and4.1.10 Bar coding (see 22.2).5. Materials and Manufacture5.1 The piles shall be made by the seamless, electricresistance welded, flash welded, or fusi

12、on welded process. Theseams of welded pipe piles shall be longitudinal, helical-butt,or helical-lap.NOTE 1For welded pipe piles, the weld should not fail when theproduct is properly fabricated and installed and subjected to its intendedend use.6. Process6.1 The steel shall be made by one or more of

13、the followingprocesses: open-hearth, basic-oxygen, or electric-furnace.1This specification is under the jurisdiction of ASTM Committee A01 on Steel,Stainless Steel and Related Alloys and is the direct responsibility of SubcommitteeA01.09 on Carbon Steel Tubular Products.Current edition approved Sept

14、. 1, 2018. Published October 2018. Originallyapproved in 1944. Last previous edition approved in 2010 as A252 10. DOI:10.1520/A0252-10R18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume

15、information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standard

16、ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.17. Chemical Composition7.1 The steel shall contain no more than 0.050 % phospho-rous.8. Heat

17、 Analysis8.1 Each heat analysis shall conform to the requirementspecified in 7.1. When requested by the purchaser, the appli-cable heat analyses shall be reported to the purchaser or thepurchasers representative.9. Product Analysis9.1 Chemical analysis shall be in accordance with TestMethods, Practi

18、ces, and Terminology A751.9.2 It shall be permissible for the purchaser to make productanalyses using samples from lots of pipe piles as follows:Pipe Size OutsideDiameter, in. (mm)Number of Samples and Size of LotUnder 14 (355.6) 2 from 200 pipe or fraction thereof14 to 36, incl (355.6 to 914) 2 fro

19、m 100 pipe or fraction thereofOver 36 (914) 2 from 3000 ft (914 m) or fraction thereofThe product analyses shall conform to the requirement in7.1.9.3 If the chemical compositions of both of the samplesrepresenting a lot fail to conform to the specified requirement,the lot shall be rejected or analys

20、es of four additional samplesselected from the lot shall be made, and each shall conform tothe specified requirement. If the chemical composition of onlyone of the samples representing a lot fails to conform to thespecified requirement, the lot shall be rejected or analyses oftwo additional samples

21、selected from the lot shall be made, andeach shall conform to the specified requirement.10. Tensile Requirements10.1 The material shall conform to the requirements as totensile properties prescribed in Tables 1 and 2.10.2 The yield point shall be determined by the drop of thebeam, by the halt in the

22、 gage of the testing machine, by the useof dividers, or by other approved methods. When a definiteyield point is not exhibited, the yield strength corresponding toTABLE 1 Tensile RequirementsNOTE 1Where an ellipsis (.) appears in this table, there is no requirement.Grade 1 Grade 2 Grade 3Tensile str

23、ength, min, psi (MPa) 50 000 (345) 60 000 (415) 66 000 (455)Yield point or yield strength, min, psi (MPa) 30 000 (205) 35 000 (240) 45 000 (310)Basic minimum elongation for nominal wall thicknesses516 in. (7.9 mm) or more:Elongation in 8 in. (203.2 mm), min, % 18 14 . . .Elongation in 2 in. (50.8 mm

24、), min, % 30 25 20For nominal wall thicknesses less than516 in. (7.9 mm), the deduction fromthe basic minimum elongation in 2 in. (50.08 mm) for each132 - in. (0.8 mm)decrease in nominal wall thickness below516 in. (7.9 mm), in percentage points1.50A1.25A1.0AATable 2 gives the computed minimum value

25、s:TABLE 2 Calculated Minimum Elongation ValuesANominal Wall Thickness Elongation in 2 in. (50.8 mm), min, %in. mm Grade 1 Grade 2 Grade 3516 or 0.312 7.9 30.00 25.00 20.00932 or 0.281 7.1 28.50 23.75 19.0014 or 0.250 6.4 27.00 22.50 18.00732 or 0.219 5.6 25.50 21.25 17.00316 or 0.188 4.8 24.00 20.00

26、 16.001164 or 0.172 4.4 23.25 19.50 15.50532 or 0.156 4.0 22.50 18.75 15.00964 or 0.141 3.6 21.75 18.25 14.5018 or 0.125 3.2 21.00 17.50 14.00764 or 0.109 2.8 20.25 16.75 13.50AThe above table gives the calculated minimum elongation values for various nominal wall thicknesses. Where the specified no

27、minal wall thickness is intermediate to thoseshown above, the minimum elongation value shall be determined as follows:Grade1 E =48t + 15.002 E =40t + 12.503 E =32t + 10.00where:E = elongation in 2 in., %, andt = specified nominal wall thickness, in.A252 10 (2018)2a permanent offset of 0.2 % of the g

28、age length of the specimen,or to a total extension of 0.5 % of the gage length under loadshall be determined.11. Weights Per Unit Length11.1 The weights per unit length for various sizes of pipepiles are listed in Table 3.11.2 For pipe pile sizes not listed in Table 3, the weight perunit length shal

29、l be calculated as follows:W 5 10.69D 2 t!t (1)where:W = weight per unit length, lb/ft,D = specified outside diameter, in., andt = specified nominal wall thickness, in.12. Permissible Variations in Weights and Dimensions12.1 WeightEach length of pipe pile shall be weighedseparately and its weight sh

30、all not vary more than 15 % over or5 % under its theoretical weight, calculated using its length andits weight per unit length (see Section 11).12.2 Outside DiameterThe outside diameter of pipe pilesshall not vary more than 61 % from the specified outsidediameter.12.3 Wall ThicknessThe wall thicknes

31、s at any point shallnot be more than 12.5 % under the specified nominal wallthickness.NOTE 2The minimum permissible wall thickness on inspection isshown in Table X1.1 (seeAppendix) for various nominal wall thicknesses.13. Lengths13.1 Pipe piles shall be furnished in single random lengths,double rand

32、om lengths, or in uniform lengths as specified inthe purchase order, in accordance with the following limits:Single random lengths 16 to 25 ft (4.88 to 7.62 mm), inclDouble random lengths over 25 ft (7.62 m) with a minimum averageof 35 ft (10.67 m)Uniform lengths length as specified with a permissib

33、levariation of 1 in.13.2 Lengths that have been spliced at the mill by weldingshall be acceptable as the equivalent of unspliced lengthsprovided tension test specimens cut from sample splicesconform to the tensile strength requirements prescribed inTables 1 and 2. The welding bead shall not be remov

34、ed for thistest. Such specimens shall be made in accordance with theprovisions specified in Sections 1618.14. Workmanship, Finish, and Appearance14.1 The finished pipe piles shall be reasonably straight andshall not contain imperfections in such number or of suchcharacter as to render the pipe unsui

35、table for pipe piles.14.2 Surface imperfections having a depth not in excess of25 % of the specified nominal wall thickness shall be accept-able. It shall be permissible to establish the depth of suchimperfections by grinding or filing.14.3 Surface imperfections having a depth in excess of 25 %of th

36、e specified nominal wall thickness shall be considered tobe defects. It shall be permissible for defects not deeper than3313 % of the specified nominal wall thickness to be repairedby welding, provided that the defect is completely removedprior to welding.15. Ends15.1 Pipe piles shall be furnished w

37、ith plain ends. Unlessotherwise specified, pipe piles shall have either flamecut ormachinecut ends, with the burrs at the ends removed. Whereends are specified to be beveled, they shall be beveled to anangle of 30 +5, 0, measured from a line drawn perpendicularto the axis of the pipe pile.16. Number

38、 of Tests16.1 One tension test shall be made on one length orfraction thereof of each size, or one piece of skelp representingeach lot of 200 lengths or fraction thereof of each size.16.2 A retest shall be allowed if the percentage of elonga-tion of any test tension specimen is less than that prescr

39、ibed inTables 1 and 2 and any part of the fracture is more than34 in.(19 mm) from the center of the gage length for test specimenshaving a 2in. (50 mm) gage length, or is outside of the middlethird of the gage length for test specimens having an 8in. (200mm) gage length, as indicated by scribe scrat

40、ches marked onthe specimen before testing. A retest shall also be allowed ifany part of the fracture is in an inside or outside surfaceimperfection.16.3 It shall be permissible to discard any test specimen thatshows defective machining or develops imperfections andsubstitute another test specimen.17

41、. Retests17.1 If the results of the tension test representing any lot failto conform to the applicable requirements prescribed in Tables1 and 2, the lot shall be rejected or retested using twoadditional lengths from the lot, with each such test beingrequired to conform to such specified requirements

42、.A252 10 (2018)3TABLE 3 Common Sizes and Weights Per Unit LengthAOutside Diameter, in. Nominal Wall Thickness,in.BWeight per Unit Lengths,lb/ftCOutside Diameter, in.BNominal Wall Thickness,in.BWeight per Unit Lengths,lb/ftC6 0.134 8.40 12 0.134 17.000.141 8.83 0.141 17.870.156 9.75 0.150 19.000.164

43、10.23 0.164 20.750.172 10.72 0.172 21.750.179 22.628 0.141 11.85 0.188 23.740.172 14.39 0.203 25.600.219 27.58858 0.109 9.92 0.230 28.940.141 12.79 0.250 31.400.172 15.54 0.281 35.200.188 16.96 0.312 38.980.203 18.280.219 19.68 1234 0.109 14.730.250 22.38 0.134 18.070.277 24.72 0.141 19.010.312 27.7

44、3 0.150 20.200.322 28.58 0.164 22.070.344 30.45 0.172 23.130.375 33.07 0.179 24.050.438 38.33 0.188 25.250.500 43.43 0.203 27.230.219 29.3410 0.109 11.53 0.230 30.780.120 12.67 0.250 33.410.134 14.13 0.281 37.460.141 14.86 0.312 41.480.150 15.79 0.330 43.810.164 17.24 0.344 45.620.172 18.07 0.375 49

45、.610.179 18.79 0.438 57.650.188 19.72 0.500 65.480.203 21.260.219 22.90 14 0.134 19.860.230 24.02 0.141 20.890.250 26.06 0.150 22.210.164 24.261034 0.109 12.40 0.172 25.430.120 13.64 0.179 26.450.134 15.21 0.188 27.760.141 15.99 0.203 29.940.150 17.00 0.219 32.260.164 18.56 0.230 33.860.172 19.45 0.

46、250 36.750.179 20.23 0.281 41.210.188 21.23 0.312 45.650.203 22.89 0.344 50.220.219 24.65 0.375 54.620.230 25.87 0.438 63.500.250 28.06 0.469 67.840.279 31.23 0.500 72.160.307 34.270.344 38.270.365 40.520.438 48.280.500 54.79A252 10 (2018)4TABLE 3 ContinuedOutside Diameter, in. Nominal Wall Thicknes

47、s,in.BWeight per Unit Lengths,lb/ftCOutside Diameter, in.BNominal Wall Thickness,in.BWeight per Unit Lengths,lb/ftC16 0.134 22.73 20 0.141 29.930.141 23.90 0.172 36.460.150 25.42 0.188 39.820.164 27.76 0.219 46.310.172 29.10 0.250 52.780.179 30.27 0.281 59.230.188 31.78 0.312 65.660.203 34.28 0.344

48、72.280.219 36.95 0.375 78.670.230 38.77 0.438 91.590.250 42.09 0.469 97.920.281 47.22 0.500 104.230.312 52.320.344 57.57 22 0.172 40.130.375 62.64 0.188 43.840.438 72.86 0.219 50.990.469 77.87 0.250 58.130.500 82.85 0.281 65.240.312 72.3418 0.141 26.92 0.375 86.690.172 32.78 0.438 100.960.188 35.80

49、0.469 107.950.219 41.63 0.500 114.920.230 43.690.250 47.44 24 0.172 43.810.281 53.23 0.188 47.860.312 58.99 0.219 55.670.344 64.93 0.250 63.470.375 70.65 0.281 71.250.438 82.23 0.312 79.010.469 87.89 0.375 94.710.500 93.54 0.438 110.320.469 117.980.500 125.62ASubject to agreement between the manufacturer and the purchaser, sizes and weights per unit length other than those listed shall be permitted.B1 in. = 25.4 mmC1 lb/ft = 1.49 kg/m.18. Test Specimens and Test Methods18.1 The tension test specimens and test methods shall be inaccordance wi