ASTM C1007-2011a Standard Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories《安装承重(横向和轴向)钢钉及相关配件的标准规格》.pdf

上传人:diecharacter305 文档编号:463040 上传时间:2018-11-27 格式:PDF 页数:4 大小:78.17KB
下载 相关 举报
ASTM C1007-2011a Standard Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories《安装承重(横向和轴向)钢钉及相关配件的标准规格》.pdf_第1页
第1页 / 共4页
ASTM C1007-2011a Standard Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories《安装承重(横向和轴向)钢钉及相关配件的标准规格》.pdf_第2页
第2页 / 共4页
ASTM C1007-2011a Standard Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories《安装承重(横向和轴向)钢钉及相关配件的标准规格》.pdf_第3页
第3页 / 共4页
ASTM C1007-2011a Standard Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories《安装承重(横向和轴向)钢钉及相关配件的标准规格》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: C1007 11aStandard Specification forInstallation of Load Bearing (Transverse and Axial) SteelStuds and Related Accessories1This standard is issued under the fixed designation C1007; the number immediately following the designation indicates the year oforiginal adoption or, in the case of

2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers the installation and erectionrequirements for load bearing (transver

3、se and axial) steel studsand related accessories 0.0329 in. (0.836 mm) to 0.1120 in.(2.845 mm) thick.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not cons

4、idered standard.1.3 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.2. Referenced Documents2.1 ASTM Standards:2C11 Terminology Relating

5、to Gypsum and Related BuildingMaterials and SystemsC841 Specification for Installation of Interior Lathing andFurringC954 Specification for Steel Drill Screws for the Applica-tion of Gypsum Panel Products or Metal Plaster Bases toSteel Studs from 0.033 in. (0.84 mm) to 0.112 in. (2.84mm) in Thicknes

6、sC955 Specification for Load-Bearing (Transverse andAxial) Steel Studs, Runners (Tracks), and Bracing orBridging for Screw Application of Gypsum Panel Productsand Metal Plaster BasesC1063 Specification for Installation of Lathing and Furringto Receive Interior and Exterior Portland Cement-BasedPlast

7、er2.2 American Iron and Steel Institute Publication (AISI):S100 North American Specification for the Design of Cold-Formed Steel Structural Members 2007 Edition32.3 American Welding Society Documents (AWS):D1.3 Specification for Welding Sheet Steel in Structures42.4 Military Specification:MIL-P-2103

8、5 Paint, High Zinc Dust Content, GalvanizingRepair52.5 Federal Specification:FF-P-395 Pin, Drive, Guided and Pin Drive, Power Actu-ated Fasteners for Power Actuated and Hand ActuatedFastening Tools5AISI COSP Code of Standard Practice for Cold-FormedSteel Structural Framing 2006 Edition53. Terminolog

9、y3.1 Definitions shall be in accordance with TerminologyC11.3.2 Definitions of Terms Specific to This Standard:3.2.1 axial loads, nthose loads applied to a member in thesame plane as its major centroidal axis.3.2.2 cripple studs, nless than full height studs above aheader or below a sill.3.2.3 frami

10、ng members, nstuds joist, runners (tracks),bridging and bracing and related accessories.3.2.4 header, nthe stud assembly or the track assembly, orboth, placed at a right angle to supporting studs that creates thetop of a framed opening.3.2.5 jack stud, na framing member which providessupport at the

11、end of a header.3.2.6 panelized construction, nfabrication of framingmembers into an assembly prior to erection.3.2.7 sill, nthe stud assembly or the track assembly, orboth, placed at a right angle to supporting studs that creates thebottom of a framed opening.1This specification is under the jurisd

12、iction of ASTM Committee C11 onGypsum and Related Building Materials and Systems and is the direct responsibilityof Subcommittee C11.03 on Specifications for theApplication of Gypsum and OtherProducts in Assemblies.Current edition approved Aug. 1, 2011. Published Septemeber 2011. Originallyapproved

13、in 1983. Last previous edition approved in 2011 as C1007 11. DOI:10.1520/C1007-11A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary pa

14、ge onthe ASTM website.3Available from American Iron and Steel Institute (AISI), 1140 ConnecticutAve., NW, Suite 705, Washington, DC 20036, http:/www.steel.org.4Available from American Welding Society (AWS), 550 NW LeJeune Rd.,Miami, FL 33126, http:/www.aws.org.5Available from Standardization Documen

15、ts Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.8 transverse loads, nth

16、ose loads applied to a memberin a plane perpendicular to its major centroidal axis.4. Storage of Materials4.1 Material shall be received and stored in accordance withAISI COSP F3 Delivery, Handling and Storage of Materials.5. Materials5.1 Framing membersSpecification C955.5.2 Zinc-rich paintMIL-P-21

17、035.5.3 Steel drill screwsSpecification C954. Screws shallhave rust inhibitive coating suitable for the intended installa-tion.5.4 Power actuated drive pinsFF-P-395.6. Fastenings and Attachments6.1 Anchorage of the tracks to the structure shall be withmethods designed for the specific application of

18、 sheet steel tothat surface. Size, penetration, type, and spacing shall bedetermined by design.6.2 Welds shall conform to the requirements of AWS D1.3and AISI S100, Section E2. Welds shall be butt, fillet, spot, orgroove type, the appropriateness of which shall be determinedby, and within, the desig

19、n calculations. All welds shall betouched-up using zinc rich paint.6.3 Steel drill screws shall be of the minimum diameterindicated by the design of that particular attachment detail.Penetration through joined materials shall not be less than threeexposed threads.6.4 Wire tying in structural applica

20、tions shall not be permit-ted.7. Tolerances7.1 Vertical alignment (plumbness) of studs shall be within1/960 (18 in. in 10 ft 0 in.) of the span.7.2 Horizontal alignment (levelness) of walls shall be within1/960 (18 in. in 10 ft 0 in.) of their respective lengths.7.3 Spacing of the framing members sh

21、all not be more than618 in. (3 mm) from the designed spacing, provided that thecumulative error does not exceed the requirements of thefinishing materials.7.4 Squareness of the prefabricated panels shall be not morethan18 in. (3 mm) out of square within the length of that panel.INSTALLATION8. Genera

22、l Installation8.1 Methods of construction shall be either stickbuilt orpanelized.8.2 Stud to track connections shall be designed to meet orexceed the design loads required.8.3 Allowance for vertical deflection of the structure shallbe as required by the designer.8.4 Transversely loaded studs shall n

23、ot be required to sitsquarely in tracks, but shall be attached to the tracks.8.5 Axially loaded studs shall be fabricated with the studsseated squarely within18 in. (3 mm) of the web portion of thetop and bottom tracks and shall be attached to the tracks.8.6 All axially loaded members shall be align

24、ed vertically toallow for full transfer of the loads down to the foundation.Vertical alignment shall be maintained at floor/wall intersec-tions.8.7 Bearing shall be provided under tracks to provide forload transfer in axially loaded assembles.8.8 Additional corrosion protection shall not be required

25、 onedges of metallic coated steel framing members, shop or fieldcut, punched or drilled.8.9 Cutting and Splicing of Members:8.9.1 Cutting of steel framing members shall be accom-plished with a saw or shear.8.9.2 Torch cutting of framing members shall not be per-mitted.8.9.3 Splicing of axially loade

26、d framing members shall notbe permitted.8.9.4 Cutting of flanges in stud and joist framing membersshall not be permitted.8.9.5 Cutting of additional holes other than those providedby the manufacturer in framing members shall not be permit-ted.8.10 Temporary bracing shall be provided and left in plac

27、euntil the work is permanently stabilized.8.11 Bridging shall be of the size and type shown on theshop drawings and as called for in the design calculations. Forfurther description of the shop drawings see Annex A3.8.12 Header and Jack Stud Installation:8.12.1 Headers shall be installed in all openi

28、ngs in axiallyloaded walls that are larger than the stud spacing in that wall.8.12.1.1 Headers shall be installed so that they lie whollywithin the width of the stud wall.8.12.1.2 Insulation (equal to the job requirements) shall beplaced in all jamb and header type conditions that will be inaccessib

29、le after their installation into the wall.8.12.2 Jack studs shall be securely connected to the headerand must seat squarely in the lower track of the wall inaccordance with 8.4.8.12.3 If the header is designed to be installed immediatelyabove the wall opening the cripple studs that occur over thehea

30、der shall be designed to carry all superimposed loads.8.13 Wall track (runners) shall not be used to support anyload unless specifically designed for that purpose.9. Panelized Construction9.1 Panels shall be designed to resist all construction andhandling loads as well as live loads.9.2 Handling and

31、 lifting of prefabricated panels shall notcause permanent distortion in any member or collateral mate-rial.9.3 All stud-to-track connections shall be installed prior tohoisting the panel.9.4 Where splicing of the track is necessary between studspacings, a piece of stud not less than 12 in. (305 mm)

32、longshall be placed in the track fastened with not less than twoscrews per flange to each piece of track or welds shall beprovided as required.NOTE 1Claddings may be permitted to be attached prior to panelinstallation.C1007 11a29.5 Attachment of the panel to the structure shall be asshown on the des

33、ign drawings.9.6 All panels shall be aligned to provide continuity of anywall/floor surface.10. Stick Built (Non-Panelized) Members10.1 Tracks shall be aligned accurately at supporting struc-ture and shall be fastened to the structure.10.2 Track intersections shall butt evenly.10.3 Doors, windows, a

34、nd other items installed in the wallshall be securely anchored to the wall by means of clips,angles, screws, bolts, etc.11. Keywords11.1 axial; loadbearing; runners; steel; studs; tracks;transverseANNEXES(Mandatory Information)A1. DESIGN REQUIREMENTSA1.1 Physical properties and allowable load capabi

35、lities ofmaterials shall be developed in accordance with AISI S100.A1.2 Studs shall be spaced to suit the design requirementsand limitations of collateral materials.A1.3 All applicable loads, strains, deflections, shear andweb crippling, and bending of all sections shall be examined.A1.4 All connect

36、ions (member-to-member and member-to-structure) shall be examined taking into account all relevantphysical strengths and properties.A1.5 Selected walls shall be designed to provide framestability and lateral load resistance. Diagonal steel strapping orother engineered methods shall be used to provid

37、e framestability and lateral load resistance. Diagonal steel strappingshall be used to transfer lateral loads to the structure andfoundation. Additional studs shall be provided to resist thevertical component of the loads from the diagonal bracing.A1.6 Wall bridging shall be designed to provide resi

38、stanceto minor axis bending and rotation of wall studs.A2. INSTALLATION REQUIREMENTSA2.1 Gypsum board shall be attached to the steel studs inaccordance with the appropriate specification.A2.2 Metal plaster bases shall be attached in accordancewith Specification C841 or Specification C1063, except sc

39、rewheads shall be of a size and type suitable for positive (nomovement) attachment.A2.3 When diaphragm rated components are substituted forbridging, they shall be installed prior to loading of the wall. Ifcomponents are installed on one side of the wall only, then theother stud flanges shall be brid

40、ged with suitable bridging.Bridging is not required to be removed when diaphragm ratedcomponents are installed.A2.4 Care shall be taken to allow for additional studs atpanel intersections, corners, doors, window, control joints, etc.A2.5 Provision for structure movement shall be provided asindicated

41、 and necessary by design or code requirements.A2.6 Properly designed splices, cutting of flanges, andholes other than those provided by the manufacturer shall beapproved in writing by the engineer of record.A2.7 Care shall be taken to properly distribute constructionmaterials so that they do not exc

42、eed the project design loads.A3. SUBMITTALSA3.1 The following items shall be considered for approvalprior to delivery of materials to the site:A3.1.1 Shop DrawingsDrawings shall illustrate materi-als; shop coatings; steel thickness; details of fabrication; detailsof attachment to adjoining work; siz

43、e, location, spacing offasteners for attaching framing to itself; details of attachment tothe structure; accessories and their installation; and criticalinstallation procedures. Drawings shall include plans, eleva-tions, sections and details.A3.1.2 SamplesSamples shall be representative pieces ofall

44、 framing component parts and accessories.A3.1.3 CertificationCertification shall be a statementfrom the manufacturer certifying that the materials conform tothe appropriate requirements as outlined in the contract docu-ments.A3.1.4 CalculationsEngineering calculations shall beprepared verifying the

45、assemblys ability to meet or exceeddesign requirements as required by local codes and authorities.C1007 11a3A3.1.5 Descriptive LiteratureManufacturers literatureshall contain product and installation specifications and details.SUMMARY OF CHANGESCommittee C11 has identified the location of selected c

46、hanges to this specification since the last issue,C1007 11, that may impact the use of this specification. (Approved August 1, 2011)(1) Deleted 4.1 through 4.3.(2) Added 4.1.(3) Added AISI COSP to 2.2.Committee C11 has identified the location of selected changes to this specification since the last

47、issue,C1007 08a, that may impact the use of this specification. (Approved May 15, 2011)(1) Revised 2.2.(2) Revised A1.1.(3) Revised 6.2.Committee C11 has identified the location of selected changes to this specification since the last issue,C1007 08, that may impact the use of this specification. (A

48、pproved November 1, 2008)(1) Revised 6.2.Committee C11 has identified the location of selected changes to this specification since the last issue,C1007 04, that may impact the use of this specification. (Approved September 1, 2008)(1) Revised 8.8.ASTM International takes no position respecting the v

49、alidity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standa