1、BSI Standards PublicationBS EN 13451-11:2014Swimming pool equipmentPart 11: Additional specific safetyrequirements and test methods formoveable pool floors and moveablebulkheadsCopyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reprodu
2、ction or networking permitted without license from IHS-,-,-BS EN 13451-11:2014 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 13451-11:2014.It supersedes BS EN 13451-11:2004 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCo
3、mmittee SW/136/8, Swimming pools and aquatic equipment.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The Britis
4、h Standards Institution 2014. Published by BSI StandardsLimited 2014ISBN 978 0 580 79612 8ICS 97.220.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2
5、014.Amendments issued since publicationDate Text affectedCopyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13451-11:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISC
6、HE NORM EN 13451-11 January 2014 ICS 97.220.10 Supersedes EN 13451-11:2004English Version Swimming pool equipment - Part 11: Additional specific safety requirements and test methods for moveable pool floors and moveable bulkheads quipement de piscine - Partie 11: Exigences de scurit et mthodes dessa
7、i complmentaires propres aux fonds de bassins mobiles et cloisons mobiles Schwimmbadgerte - Teil 11: Zustzliche besondere sicherheitstechnische Anforderungen und Prfverfahren fr hhenverstellbare Zwischenbden und bewegliche Beckenabtrennungen This European Standard was approved by CEN on 6 December 2
8、013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained
9、 on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CE
10、NELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, It
11、aly, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Av
12、enue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13451-11:2014 ECopyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or
13、 networking permitted without license from IHS-,-,-BS EN 13451-11:2014EN 13451-11:2014 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .4 4 Classification 5 5 Safety requirements 5 5.1 Moveable pool floors .5 5.2 Moveable bulkheads 8 6 Test methods . 11 6.1
14、General . 11 6.2 Closure devices for perimetral gap Flexible closure devices . 11 7 Instructions and information . 13 Annex A (normative) Operational instructions for moveable floors . 14 Annex B (normative) Operational instructions for moveable bulkheads . 15 Bibliography . 16 Copyright British Sta
15、ndards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13451-11:2014EN 13451-11:2014 (E) 3 Foreword This document (EN 13451-11:2014) has been prepared by Technical Committee CEN/TC 136 “Sp
16、orts, playground and other recreational facilities and equipment”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2014, and conflicting national stan
17、dards shall be withdrawn at the latest by July 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 13451
18、-11:2004. In relation to EN 13451-11:2004, the following significant changes have been made: a) normative references have been updated; b) requirements for the recessed ledges and steps have been modified; c) safety requirements for the prevention of interference with the circulation system have bee
19、n added; d) width of the walkable area behind the starting platform has been changed; e) test procedure for rigid closure devices has been modified. EN 13451, Swimming pool equipment consists of the following parts: Part 1: General safety requirements and test methods; Part 2: Additional specific sa
20、fety requirements and test methods for ladders, stepladders and handle bends; Part 3: Additional specific safety requirements and test methods for inlets and outlets and water/air based water leisure features; Part 4: Additional specific safety requirements and test methods for starting platforms; P
21、art 5: Additional specific safety requirements and test methods for lane lines; Part 6: Additional specific safety requirements and test methods for turning boards; Part 7: Additional specific safety requirements and test methods for water polo goals; Part 10: Additional specific safety requirements
22、 and test methods for diving platforms, diving springboards and associated equipment; Part 11: Additional specific safety requirements and test methods for moveable pool floors and moveable bulkheads. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the foll
23、owing countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands,
24、Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS E
25、N 13451-11:2014EN 13451-11:2014 (E) 4 1 Scope This part of EN 13451 specifies safety requirements for moveable pool floors and moveable bulkheads in addition to the general safety requirements of EN 13451-1 and should be read in conjunction with it. The requirements of this part of EN 13451 take pri
26、ority over those in EN 13451-1. This part of EN 13451 is applicable to manufactured moveable pool floors and moveable bulkheads for use in classified swimming pools as specified in EN 15288-1 and EN 15288-2. 2 Normative references The following documents, in whole or in part, are normatively referen
27、ced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 13451-1:2011, Swimming pool equipment - Part 1: General safety requiremen
28、ts and test methods EN 13451-4:2001, Swimming pool equipment - Part 4: Additional specific safety requirements and test methods for starting platforms EN 13451-5:2001, Swimming pool equipment - Part 5: Additional specific safety requirements and test methods for lane lines EN 13451-10, Swimming pool
29、 equipment - Part 10: Additional specific safety requirements and test methods for diving platforms, diving springboards and associated equipment EN 60947-5-5, Low-voltage switchgear and controlgear - Part 5-5: Control circuit devices and switching elements - Electrical emergency stop device with me
30、chanical latching function (IEC 60947-5-5) EN ISO 12100, Safety of machinery - General principles for design - Risk assessment and risk reduction (ISO 12100) EN ISO 13850, Safety of machinery - Emergency stop - Principles for design (ISO 13850) EN ISO 13857, Safety of machinery - Safety distances to
31、 prevent hazard zones being reached by upper and lower limbs (ISO 13857) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 13451-1:2011 and the following apply. 3.1 moveable pool floor adjustable floor designed to change the water depth of the pool 3.2
32、open side of a moveable pool floor open side of a moveable floor not moving alongside a pool wall 3.3 water depth usable depth measured between water surface and the upper surface of a moveable floor Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy N
33、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13451-11:2014EN 13451-11:2014 (E) 5 3.4 moveable bulkhead moveable structure, providing a solid partition to divide a pool into sections 3.5 closure device flexible device used to close gaps between the moveable
34、floor/bulkhead and pool wall/floor Note 1 to entry: For example, flexible lips, rubber gaskets, etc. can be used. 4 Classification For the classification see Table 1. Table 1 Classification Moveable pool floors Moveable bulkheads Type 1 Moveable floors bearing live loads by buoyancy only. Moveable b
35、ulkheads bearing live loads by buoyancy only Type 2 Moveable floors bearing live loads by drive systems supported by the pool structure. Moveable bulkheads supported by the pool structure. 5 Safety requirements 5.1 Moveable pool floors 5.1.1 General Moveable pool floors which fall under Directive 20
36、06/42/EC 1 on Safety of Machinery shall also comply with EN ISO 12100, EN ISO 13850 and EN ISO 13857. NOTE It may be necessary to tighten the construction tolerances of the structure and finishes within the basin in order to meet the tolerances set out within this European Standard. The gradient of
37、a moveable floor in water depth 1 350 mm shall be 6,6 %. The moveable pool floor design shall ensure the effectiveness of the water treatment system. In presence of a moveable pool floor, the pool water treatment system should be specifically designed considering possible changes in designation (e.g
38、. a swimmers pool used as non-swimmers pool). A dye test to check the correct water distribution of the complete installation, with the moveable floor in the lowest working position, is advisable. As moveable floor influences the water distribution the result of the dye test has to be evaluated in a
39、 different way (see EN 15288-2:2008, Annex A). Moveable floors shall allow inspection, cleaning and maintenance of the area underneath. 5.1.2 Structural integrity The structural integrity of moveable floors shall be verified using the following independently assessed criteria: a vertical area load o
40、f 600 N/m2, evenly applied; a concentrated vertical area load of 2 000 N/m2over a square area of 1 m2at any point; Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS
41、EN 13451-11:2014EN 13451-11:2014 (E) 6 a concentrated vertical area load of 2 000 N/m2over an area of 2 m 2 m focussed in front of the means of exit or similar areas. NOTE The above values are valid only for use in swimming and associated activities. Different kind of uses (e.g. as a stage, a dancin
42、g floor, etc.) may require the use of different loads. 5.1.3 Inadvertent movements Movements of a moveable floor different from those foreseen by design shall be prevented. The risks coming from small foreseeable movements (partial submersion or flexion caused by vertical area load, and so on) durin
43、g use and maintenance in water shall be prevented. NOTE The requirement can be complied with e.g. by design, securing systems, etc. 5.1.4 Prevention of entrapment Gaps on the surface of a moveable floor shall be 8 mm in one direction. The gap between the rigid part of a moveable floor and the pool s
44、hall be 50 mm in one direction. When the gap is greater than 8 mm a closure device shall be used. The design of a closure device shall involve that if a finger or toe can pass between the flexible closure device and the swimming pool walls, it shall also be possible to pull back the finger or toe. T
45、he movement of the rigid part of the moveable floor or moveable bulkhead is to be limited to avoid entrapment of a finger or toe. To achieve this, the design shall be as follows: The closure device shall have a shape which will not cut, entrap or injure (e.g. round shaped profiles). The horizontal m
46、ovement of the moveable floor or moveable bulkhead when positioned in the operating mode shall be limited to 50 % of the flexibility of the closure device. In the case of recessed ladders, the moveable floors working positions should abut against the vertical surface of the recessed ledges/steps in
47、order to avoid entrapment. These closure devices shall pass the test defined in 6.2. 5.1.5 Slip resistance When the water depth is 1 350 mm the slip resistance of the walkable area of a moveable floor shall comply with rating group 18 according to EN 13451-1:2011, Table 1. 5.1.6 Prevention of fallin
48、g off When a moveable floor has an open end, the hazards connected with falling off this end shall be prevented by the use of a moveable bulkhead, located at least at the water surface, to enclose the area of the moveable floor (preferred); by the use of a highly visible floating line, conforming to
49、 EN 13451-5, installed over the moveable floor surface, 1 m in front of the floor open end. Furthermore, the area 100 mm wide from the open end of the moveable floor edge shall be distinguishable by a contrasting colour. Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy No