BS EN 50525-2-82-2011 Electric cables Low voltage energy cables of rated voltages up to and including 450 750 V (U0 U) Cables for general applications Cables with crosslinked elast.pdf

上传人:figureissue185 文档编号:575013 上传时间:2018-12-13 格式:PDF 页数:14 大小:852.32KB
下载 相关 举报
BS EN 50525-2-82-2011 Electric cables Low voltage energy cables of rated voltages up to and including 450 750 V (U0 U) Cables for general applications Cables with crosslinked elast.pdf_第1页
第1页 / 共14页
BS EN 50525-2-82-2011 Electric cables Low voltage energy cables of rated voltages up to and including 450 750 V (U0 U) Cables for general applications Cables with crosslinked elast.pdf_第2页
第2页 / 共14页
BS EN 50525-2-82-2011 Electric cables Low voltage energy cables of rated voltages up to and including 450 750 V (U0 U) Cables for general applications Cables with crosslinked elast.pdf_第3页
第3页 / 共14页
BS EN 50525-2-82-2011 Electric cables Low voltage energy cables of rated voltages up to and including 450 750 V (U0 U) Cables for general applications Cables with crosslinked elast.pdf_第4页
第4页 / 共14页
BS EN 50525-2-82-2011 Electric cables Low voltage energy cables of rated voltages up to and including 450 750 V (U0 U) Cables for general applications Cables with crosslinked elast.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50525-2-82:2011Electric cables Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) -Part 2-82: Cables for general applications Cables with cros

2、slinked elastomeric insulation for decorative chainsBS EN 50525-2-82:2011 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN50525-2-82:2011.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/20/17, Electric Cables - Low voltage.A list o

3、f organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2011ISBN 978 0 580 64373 6ICS 29.060.20Compliance with a British Stan

4、dard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 September 2011.Amendments issued since publicationDate Text affectedBS EN 50525-2-82:2011 BRITISH STANDARDNational forewordThis British Standa

5、rd is the UK implementation of EN50525-2-82:2011.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/20/17, Electric Cables - Low voltage.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to

6、include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2011ISBN 978 0 580 64373 6ICS 29.060.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Poli

7、cy and Strategy Committee on 30 September 2011.Amendments issued since publicationDate Text affectedThis British Standard is the UK implementation of EN 50525-2-82:2011.In the UK, the BS EN 50525 series of standards nullontain nullomplenullsnullpersession details. The tanullle nullelonull nullest sn

8、ullmmarinulles the relationship nulletnulleen these standards:Part 1 together with Supersedes2-81 BS nullnull8-null:1nullnullnull2-null1, 2-null2 BS null00null: 200null2-11 nullin partnull, 2-12, 2-21 nullin partnull, 2-null1 BS null500:20002-11 nullin partnull, 2-21 nullin partnull, 2-51 nullin par

9、tnull, 2-8null, null-21 BS nullnull1null:20012-null1, 2-51 nullin partnull BS 6004:2000null-null1 BS 7211:19982-22, 2-null2, 2-82, null-11, null-null1 NoneNOTE All British Standards will remain current until they are withdrawn on 31 December 2012. British Standards in bold are only partially superse

10、dednull and new editions onull BS null00null and BS null211 will be introduced on 1 nullanuary 2013.BS EN 50525-2-82:2011EUROPEAN STANDARD EN 50525-2-82 NORME EUROPENNE EUROPISCHE NORM May 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotech

11、nique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50525-2-82:2011 E ICS 29.060.20 Supersedes HD 22.8 S2:1994 + A1:199

12、9 + A2:2004English version Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains Cbles lectriques - Cbles dnergie basse tension de tension

13、assigne au plus gale 450/750 V (U0/U) - Partie 2-82: Cbles pour applications gnrales - Cbles pour guirlandes lumineuses isols en matriau lastomre rticul Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) - Teil 2-82: Starkstromleitungen fr allgemeine Anwendungen - Leit

14、ungen fr Lichterketten mit vernetzter Elastomer-Isolierung This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard wi

15、thout any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other lang

16、uage made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Rep

17、ublic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50525-2-82:2011EN 50525-2-82:2011 - 2 -

18、Foreword This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric cables. The text of the draft was submitted to the formal vote and was accepted by CENELEC as EN 50525-2-82 on 2011-01-17. This document, which is one of a multipart series, supersedes HD 22.8 S2:1994 + A

19、1:1999 + A2:2004. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be i

20、mplemented at national level by publication of an identical national standard or by endorsement (dop) 2012-01-17 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-01-17 _ BS EN 50525-2-82:2011- 3 - EN 50525-2-82:2011 Contents Page 1 Scope 42 Normativ

21、e references . 43 Terms and definitions . 44 General purpose cables . 54.1 Cables used with designated lampholders H03RN-F 54.2 Cables H05RN-F and H05RNH2-F . 5Annex A (normative) Tests for cables to EN 50525-2-82 7Annex B (normative) General data . 8Annex C (normative) Requirements for compatibilit

22、y test . 9C.1 Test conditions . 9C.2 Requirements . 9Bibliography . 10Tables Table A.1 7Table B.1 General data for cable type H03RN-F . 8Table B.2 General data for cable types H05RN-F AND H05RNH2-F . 8Table C.1 Requirements . 9BS EN 50525-2-82:2011EN 50525-2-82:2011 - 4 - 1 Scope This European Stand

23、ard applies to polychloroprene, or other equivalent synthetic elastomer, sheathed cables. The cables are of rated voltages U0/U up to and including 300/500 V. The cables are intended for use as decorative chains and with designated lampholders. NOTE 1 Cables to Type H03RN-F are for use with designat

24、ed lampholders only. The 0,5 mm2size is for use with miniaturised lampholders; the 0,75 mm2size is for use with E 14 lampholders. See also HD 516. The maximum conductor operating temperature for each of the cables in this standard is 60 C. NOTE 2 HD 516 contains extensive guidance on the safe use of

25、 cables in this standard. This EN 50525-2-82 should be read in conjunction with EN 50525-1, which specifies general requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. Fo

26、r undated references, the latest edition of the referenced document (including any amendments) applies. NOTE One or more references to the standards below are in respect of a specific sub-division of that standard, for instance a clause, a table, a class or a type. Cross-references to these standard

27、s are undated and, at all times, the latest version applies. EN 50363-1 Insulating, sheathing and covering materials for low voltage energy cables Part 1: Cross-linked elastomeric insulating compounds EN 50363-2-1 Insulating, sheathing and covering materials for low voltage energy cables Part 2-1: C

28、ross-linked elastomeric sheathing compounds EN 50395 Electrical test methods for low voltage energy cables EN 50396 Non electrical test methods for low voltage energy cables EN 50525-1 Electric cables Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Part 1: General re

29、quirements EN 60228 Conductors of insulated cables (IEC 60228) EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame (IEC 60332-1-2) EN 60811-1-2 Insulating a

30、nd sheathing materials of electric and optical cables Common test methods Part 1-2: General application Thermal ageing methods (IEC 60811-1-2) EN 60811-1-4 Insulating and sheathing materials of electric and optical cables Common test methods Part 1-4: General application Tests at low temperature (IE

31、C 60811-1-4) 3 Terms and definitions For the purposes of this document the terms and definitions given in Clause 3 of EN 50525-1 apply. BS EN 50525-2-82:2011- 5 - EN 50525-2-82:2011 4 General purpose cables 4.1 Cables used with designated lampholders H03RN-F 4.1.1 Construction 4.1.1.1 Conductor The

32、conductor shall be Class 5, in accordance with EN 60228. 4.1.1.2 Sizes of cable The sizes of conductor shall be 0,5 mm2and 0,75 mm2. The number of conductors shall be 1. 4.1.1.3 Insulation The insulation shall be crosslinked elastomeric compound of Type EI 4 to EN 50363-1. 4.1.1.4 Sheath The sheath

33、shall be crosslinked elastomeric compound of Type EM 2 to EN 50363-2-1. 4.1.1.5 Marking The cable shall be marked with the CENELEC code H03RN-F. The marking shall be on the outer surface of the sheath, and shall comply with Clause 6 of EN 50525-1. 4.1.2 Requirements Each cable shall comply with the

34、appropriate requirements given in EN 50525-1, and the particular requirements of this Part. Testing shall be in accordance with Annex A, and the relevant tests indicated in column 6. The dimensions of the cables shall conform to Table B.1 for the relevant size. The requirements to be met for the com

35、patibility test shall be as given in Annex C. 4.2 Cables H05RN-F and H05RNH2-F 4.2.1 Construction 4.2.1.1 Conductor The conductor shall be Class 5, in accordance with EN 60228. 4.2.1.2 Sizes of cable The sizes of conductor shall be 0,75 mm2 to 1,5 mm2 inclusive for circular single core cable (H05RN-

36、F), and 1,5 mm2 or 2,5 mm2for two core flat cables (H05RNH2-F). 4.2.1.3 Insulation The insulation shall be crosslinked elastomeric compound of Type EI 4 to EN 50363-1. BS EN 50525-2-82:2011EN 50525-2-82:2011 - 6 - 4.2.1.4 Core identification and assembly Each core shall be identified by colour as fo

37、llows: - single core cable: brown; - two core cable: brown and blue. The cores of the two core cables shall be laid in parallel. 4.2.1.5 Sheath The sheath shall be crosslinked elastomeric compound of Type EM 2 to EN 50363-2-1. NOTE The preferred sheath colours are green or black. For two core cables

38、 the sheath shall fill the spaces between the cores, thus forming a filling. 4.2.1.6 Marking The cable shall be marked with the CENELEC code H05RN-F for circular cables, or H05RNH2-F for flat cables. The marking shall be on the outer surface of the sheath, and shall comply with Clause 6 of EN 50525-

39、1. 4.2.2 Requirements Each cable shall comply with the appropriate requirements given in EN 50525-1, and the particular requirements of this Part. Testing shall be in accordance with Annex A, and the relevant tests indicated in column 7. The dimensions of the cables shall conform to Table B.2 for th

40、e relevant size. For two core flat cables the distance between the centres of the two conductors shall comply with Table B.2, columns 3 and 4. The measured value shall be the distance between the centres of the two conductors, and the mean of the values obtained from measuring three samples shall be

41、 taken as the mean distance. The requirements to be met for the compatibility test shall be as given in Annex C. BS EN 50525-2-82:2011- 7 - EN 50525-2-82:2011 Annex A (normative) Tests for cables to EN 50525-2-82 Table A.1 1 2 3 4 5 6 7 Ref. No. Tests aCategory of test Test method described in Appli

42、cability of test Subclause EN (Sub)clause 4.1 4.2 H03RNH05RN1 Electrical tests b 1.1 Resistance of conductors T, S 50395 5 X X 1.2 Voltage test on completed cable at 2 000 V T, S 50395 6 X X 1.3 Voltage test on cores according to specified insulation thickness: 1.3.1 - at 1 500 V up to and including

43、 0,6 mm T 50395 7 X - 1.3.2 - at 2 000 V above 0,6 mm T 50395 7 - X 1.4 Absence of faults in insulation R 50395 10 X X 1.5 Surface resistance of sheath T 50395 11 X X 2 Constructional and dimensional tests 2.1 Checking of compliance with constructional provisions T, S 50525-1 Inspection and manual t

44、ests X X 2.2 Measurement of thickness of insulation T, S 50396 4.1 X X 2.3 Measurement of thickness of sheath T, S 50396 4.2/4.3 X X 2.4 Measurement of overall dimensions 2.4.1 - Mean value T, S 50396 4.4.1 X X 2.4.2 - Ovality T, S 50396 4.4.2 X X 2.4.3 - Distance between centres of conductors T, S

45、This EN 4.2.2 - X c 2.5 Solderability test (plain conductors) T 50396 8.2 X X 3 Insulation material tests T 50363-1 c - X X 4 Sheath material tests T 50363-2-1 c - X X 5 Compatibility test on cable T 60811-1-2 8.1.4 X X 6 Impact test on cable at - 25 C T 60811-1-4 8.5 X X 7 Mechanical strength of co

46、mpleted cable Flexing test followed, after immersion in water, by a voltage test at 2 000 V on cores T 50396 50395 6.2 7 - X d 8 Test under fire conditions T 60332-1-2 - X X a The order given does not imply a sequence of testing. bParticular test conditions and requirements are given in Table 1 of E

47、N 50525-1. c This EN includes all the test methods and requirements for the material. Material to be tested is taken from the finished cable. d Only for two core flat cables. BS EN 50525-2-82:2011EN 50525-2-82:2011 - 8 - Annex B (normative) General data NOTE The overall dimensions of cables have bee

48、n calculated in accordance with EN 60719. Table B.1 General data for cable type H03RN-F 1 2 3 4 5 Number and nominal cross-sectional area of conductors Thickness of insulation Specified value Thickness of sheath Specified value Mean overall diameter limits lower upper mm mm mm mm mm 1 0,5 0,6 0,6 3,

49、2 4,0 1 0,75 0,6 0,6 3,4 4,2 Table B.2 General data for cable types H05RN-F AND H05RNH2-F 1 2 3 4 5 6 7 Number and nominal cross-sectional area of conductors Thickness of insulation Specified value Distance between centres of conductors Thickness of sheath Specified value Mean overall dimensions Mean lower limit Mean upper limit lower limit upper limit mm mm mm mm mm mm mm 1 0,75 1 1,0 1 1,5 2 1,5 2 2,5 0,8 0,8 0,8 0,8 0,8 - - - 6,7

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1