1、C22.2 No. 308-14Cord reels and multi-outlet assembliesLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers represen
2、ting varied viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer and exclusion of liab
3、ilityThis document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of an
4、y third partys intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation.
5、IN NO EVENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIA
6、L DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROU
7、P HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity
8、 to another person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in t
9、his document.CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes.Intellectual property rights and ownershipAs be
10、tween CSA Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade s
11、ecrets that may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA Groups and/or other
12、s intellectual property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in this document.Patent rightsAttention is drawn
13、 to the possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is enti
14、rely their own responsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form: load this document onto a computer for the
15、 sole purpose of reviewing it; search and browse this document; and print this document if it is in PDF format.Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to have such copies, and only if this Legal Notice appears on each
16、such copy.In addition, users may not and may not permit others to alter this document in any way or remove this Legal Notice from the attached standard; sell this document without authorization from CSA Group; or make an electronic copy of this document.If you do not agree with any of the terms and
17、conditions contained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.
18、Standards Update ServiceC22.2 No. 308-14December 2014Title: Cord reels and multi-outlet assembliesTo register for e-mail notification about any updates to this publication go to shop.csa.ca click on CSA Update ServiceThe List ID that you will need to register for updates to this publication is 24235
19、07.If you require assistance, please e-mail techsupportcsagroup.org or call 416-747-2233.Visit CSA Groups policy on privacy at csagroup.org/legal to find out how we protect your personal information.ISBN 978-1-77139-858-9 2014 CSA Group All rights reserved. No part of this publication may be reprodu
20、ced in any form whatsoever without the prior permission of the publisher.Published in December 2014 by CSA Group A not-for-profit private sector organization 178 Rexdale Blvd., Toronto, Ontario, Canada M9W 1R3 To purchase standards and related publications, visit our Online Store at shop.csa.caor ca
21、ll toll-free 1-800-463-6727 or 416-747-4044.TMA trade-mar k of the Canadian S tandards Association, operating as “CSA Group”Cord reels and multi-outlet assembliesC22.2 No. 308-14C22.2 No. 308-14 Cord reels and multi-outlet assembliesDecember 2014 2014 CSA Group 1ContentsTechnical Committee on Wiring
22、 Products 3Integrated Committee on Wiring Devices (ICWD) 5Preface 81 Scope 92 Reference publications 93 Definitions 104 Cord reels and cord set storage winders 114.1 Construction 114.1.1 General 114.1.2 Enclosure 114.1.3 Mounting 124.2 Marking 134.3 Tests 134.3.1 General 134.3.2 Endurance (cord reel
23、) 134.3.3 Heating (cord reel) 144.3.4 Abnormal heating (cord reel) 144.3.5 Dielectric strength 154.3.6 Endurance (extension cord set storage winder) 154.3.7 Cord reels, switches, or other intermediate devices intended for use in other than dry locations 155 Cord-connected, multiple receptacle extens
24、ion boxes 155.1 Construction 155.1.1 For use in dwellings: 155.1.2 For use in areas other than dwellings: 165.2 Marking 175.3 Tests 175.3.1 General 175.3.2 Impact test for cord-connected, multiple receptacle extension boxes (power bars) having a nonmetallic enclosure 185.3.3 Dielectric strength 185.
25、3.4 Multiple receptacle extension boxes with varistors intended for surge suppression of connected loads 185.3.5 Wiring devices incorporating components intended for surge suppression and/or filtering of connected loads 195.3.6 Temperature test 195.3.7 Leakage current test 196 Hospital grade power b
26、ars 206.1 Construction 20C22.2 No. 308-14 Cord reels and multi-outlet assembliesDecember 2014 2014 CSA Group 26.1.1 Enclosure 206.1.2 Bonding terminal or post 206.1.3 Attachment plug 206.1.4 Flexible supply cord 206.1.5 Receptacles 206.1.6 Overcurrent protective device 216.1.7 Internal wiring 216.1.
27、8 Supply cord polarity Three-conductor cords 216.2 Marking 216.3 Tests 216.3.1 General 216.3.2 Limited short circuit 226.3.3 Ground resistance 226.3.4 Bonding impedance 226.3.5 Mold stress relief Non-metallic enclosures 226.3.6 Impact Non-metallic enclosures 236.3.7 Deflection 23C22.2 No. 308-14 Cor
28、d reels and multi-outlet assembliesDecember 2014 2014 CSA Group 3Technical Committee on Wiring ProductsK.L. Rodel Hubbell Canada LP, Pickering, Ontario Category: Producer InterestChairP. Desilets Leviton Manufacturing of Canada Limited, Pointe-Claire, Qubec Category: Producer InterestVice-ChairW.J.
29、Bryans Electro-Federation Canada, Toronto, Ontario AssociateW.J. Burr Burr and Associates, Campbell River, British Columbia Category: General InterestC. Davis Electro Cables Incorporated, Trenton, Ontario Category: Producer InterestS.W. Douglas International Association of Electrical Inspectors, Tor
30、onto, Ontario Category: General InterestD. Drysdale Nexans Canada Inc, Milton, Ontario Category: Producer InterestS.P. Hawkins Shawflex A Division of ShawCor Ltd., Toronto, Ontario AssociateR.J. Kelly Government of Nunavut-Dept of Community b) provide an explanation of circumstances surrounding the
31、actual field condition; andc) where possible, phrase the request in such a way that a specific “yes” or “no” answer will address the issue.Committee interpretations are processed in accordance with the CSA Directives and guidelines governing standardization and are available on the Current Standards
32、 Activities page at standardsactivities.csa.ca.5) This Standard is subject to review five years from the date of publication. Suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to inquiriescsagroup.org
33、 and include “Proposal for change” in the subject line: a) Standard designation (number);b) relevant clause, table, and/or figure number;c) wording of the proposed change; andd) rationale for the change.C22.2 No. 308-14 Cord reels and multi-outlet assembliesDecember 2014 2014 CSA Group 9C22.2 No. 30
34、8-14Cord reels and multi-outlet assemblies1 Scope1.1 This Standard applies to the following products rated at 600 V and less, and designed to be used in non- hazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I:a) cord reels for general use and special use cord re
35、els intended to be mounted on or in utilization equipment such as appliances, portable luminaires, extension cord set storage winders, etc.;b) cord-connected, multiple receptacle extension boxes intended to provide a convenient supply of power to portable appliances, tools, etc.; andc) hospital grad
36、e power bars rated 15 A, 125 V.1.2 The requirements of this Standard are to be used in conjunction with CSA C22.2 No. 21 and CSA C22.2 No. 42.1.3 The values given in SI (metric) units are the standard. The imperial values given in parenthesis are for information only.1.4 In this Standard, “shall” is
37、 used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of
38、 the Standard.Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.Notes to tables and figures are considered part of the table or figure and may be written as
39、requirements.Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.2 Reference publicationsCSA GroupCAN/CSA-C22.2 No. 0.4-04 (R2013) Bonding of electrical equipmentCAN/CSA-C22.2 No. 0.17-00 (R2013) Evaluation of properties of polymeric materialsC22.2
40、 No. 308-14 Cord reels and multi-outlet assembliesDecember 2014 2014 CSA Group 10C22.2 No. 8-13 Electromagnetic interference (EMI) filtersC22.2 No. 12-82 (R2013) Portable luminairesC22.2 No. 21-14 Cord sets and power-supply cordsC22.2 No. 42-10 General use receptacles, attachment plugs, and similar
41、wiring devicesC22.2 No. 49-14 Flexible cords and cablesCAN/CSA-C22.2 No. 94.2-07 (R2012) Enclosures for electrical equipment, environmental considerationsC22.2 No. 177-13 Clock-operated switchesC22.2 No. 256-05 (R2010) Direct plug-in nightlightsCAN/CSA-C22.2 No. 60065-03 (R2012) Audio, video and sim
42、ilar electronic apparatus Safety requirements3 DefinitionsThe following definitions shall apply in this StandardCord reel a device for storing flexible cord with the possibility of variable lengths of cord to be extended.Extension cord set storage winder a device consisting of a) an extension cord s
43、et;b) a take-up reel mechanism which prohibits the use of the extension cord set, unless it is completely unwound; andc) a mechanism that will not allow the reel to wind when the captive end, either connector body or attachment plug, is accessible.Hospital grade multiple receptacle extension box an
44、enclosed assembly of receptacles, with an integral over current protective device and bonding terminal or post, without an ON-OFF switch and provision for connection to supply by means of a flexible power-supply cord with grounding type attachment plug.Multiple receptacle extension box (“power bar”)
45、 an assembly consisting of an attachment plug and a power-supply cord terminated in an enclosure in which are mounted one or more receptacles. Note: A power bar may be provided with supplementary overcurrent protection, switches and indicator lights. A power bar may contain a surge protection device
46、 and an electromagnetic interference filter.C22.2 No. 308-14 Cord reels and multi-outlet assembliesDecember 2014 2014 CSA Group 114 Cord reels and cord set storage winders4.1 Construction4.1.1 General4.1.1.1 Component parts shall be of types specifically approved for the use intended or shall be inv
47、estigated as an integral part of the device.General requirements applicable to this Standard are given in the latest edition of CAN/CSA-C22.2 No. 0.4.1.1.2 A cord reel shall consist of the following:a) a length of flexible cord of a type suitable for the intended use, with insulation thickness not l
48、ess than 1.14 mm and not smaller than 16 AWG (1.31 mm2). A special use cord reel shall be provided with a flexible cord of a type and length suitable for the specific intended use, except that a heater type cord shall be restricted to use on equipment where the suitability of the combination has bee
49、n separately investigated. A cord reel with 18 AWG (0.824 mm2) conductors shall be provided with an integral nontamperable fuse or circuit breaker;b) an attachment plug at one end of the cord, unless the cord reel is intended to be permanently connected to the supply;c) a take-up reel mechanism designed for permanent connection to the supply or by means of an attachment plug, as applicable;d) a cord connector, at the load end of the supply cord. In the case of a general use cord reel, the maximum number of sets of female contacts shall be 6. The c