1、July 2016 English price group 26No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 13.220.20!%XLA“2534130www.din.deDIN
2、 EN 54-28Fire detection and fire alarm system Part 28: Non-resettable line-type heat detectors;English version EN 54-28:2016,English translation of DIN EN 54-28:2016-07Brandmeldeanlagen Teil 28: Nicht-rcksetzbare linienfrmige Wrmemelder;Englische Fassung EN 54-28:2016,Englische bersetzung von DIN EN
3、 54-28:2016-07Systmes de dtection et dalarme incendie Partie 28: Dtecteurs de chaleur de type linaire non renclenchables;Version anglaise EN 54-28:2016,Traduction anglaise de DIN EN 54-28:2016-07www.beuth.deDTranslation by DIN-Sprachendienst.In case of doubt, the German-language original shall be co
4、nsidered authoritative.Document comprises 68 pages 06.16 DIN EN 54-28:2016-07 2 A comma is used as the decimal marker. Start of application The start of application of this standard is 2016-07-01. It should be noted that, in Germany, CE conformity marking of construction products will be permitted o
5、nce this standard has been listed in the Official Journal of the European Union and/or the Bundesanzeiger (German Federal Gazette) and from the date given therein. For further information, users of this standard should refer to the websites of the European Commission or of the relevant building auth
6、ority. National foreword This document (EN 54-28:2016) has been prepared by Technical Committee CEN/TC 72 “Fire detection and fire alarm systems” (Secretariat: BSI, United Kingdom). The responsible German body involved in its preparation was DIN-Normenausschuss Feuerwehrwesen (DIN Standards Committe
7、e Firefighting and Fire Protection), Working Group NA 031-02-01-13 AK Brandmelder Gruppe B of Working Committee NA 031-02-01 AA Brandmelde- und Feueralarmanlagen. This European product standard specifies requirements for non-resettable line-type heat detectors for use in fire detection and alarm sys
8、tems permanently installed in buildings (referred to in German as “BMS” and “BMA” equipment). The system requirements and technical application rules for fire detection and fire alarm systems complying with this standard are specified in the national Standards DIN 14675 and DIN VDE 0833-2 (VDE 0833-
9、2) (see National Annex NA). Certification of conformity of these products with the requirements specified in this European Standard is based on conformity evaluation of the products carried out by “Notified Bodies” in accordance with the EU Directive No. 305/2011 (see Annex ZA). National Annex NA (i
10、nformative) Bibliography DIN 14675, Fire detection and fire alarm systems Design and operation DIN VDE 0833-2 (VDE 0833-2), Alarm systems for fire, intrusion and hold up Part 2: Requirements for fire alarm systems Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2
11、011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 54-28 February 2016 ICS 13.220.20 English Version Fire detection and fire alarm system - Part 28: Non-resettable line-type
12、heat detectors Systmes de dtection et dalarme incendie - Partie 28 : Dtecteurs de chaleur de type linaire non renclenchables Brandmeldeanlagen - Teil 28: Nicht-rcksetzbare linienfrmige Wrmemelder This European Standard was approved by CEN on 13 December 2015. CEN members are bound to comply with the
13、 CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management
14、 Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status a
15、s the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Ne
16、therlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All r
17、ights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 54-28:2016 EEN 54-28:2016 (E) 2 Contents Page European foreword . 4 Introduction 6 1 Scope 7 2 Normative references 7 3 Terms, definitions and abbreviations . 8 3.1 Terms and definitions . 8 3
18、.2 Abbreviations . 9 4 Product characteristics . 9 4.1 General 9 4.2 Nominal activation conditions/sensitivity 9 4.3 Operational reliability 10 4.4 Tolerance to supply voltage . 12 4.5 Performance parameters under fire condition . 12 4.6 Durability of Performance parameters under fire condition 12 5
19、 Testing, assessment and sampling methods 14 5.1 General . 14 5.2 Test procedures nominal activation conditions/sensitivity 18 5.3 Test procedures operational reliability. 18 5.4 Tolerance to supply parameters 20 5.5 Performance parameters under fire condition . 20 5.6 Durability of performance para
20、meters under fire condition 21 6 Assessment and Verification of Constancy of Performance (AVCP) 38 6.1 General . 38 6.2 Type testing 38 6.3 Factory Production Control (FPC) 40 7 Classification and designation . 45 8 Marking, labelling and packaging 45 8.1 Marking, labelling 45 8.2 Packaging 46 Annex
21、 A (normative) Mounting of the sensing element of NLTHD in the heat tunnel . 47 A.1 General . 47 A.2 Mounting arrangement of sensing element 47 Annex B (normative) Heat tunnel for response temperature measurements 49 B.1 General . 49 B.2 Description of the heat tunnel . 49 Annex C (informative) Cons
22、truction of the heat tunnel 50 C.1 General . 50 C.2 Heat tunnel construction . 50 Annex D (normative) Test arrangement for vibration tests for sensing element . 52 DIN EN 54-28:2016-07 EN 54-28:2016 (E) 3 D.1 General . 52 D.2 Test setup 52 Annex E (normative) Test apparatus for impact test on the se
23、nsing element 53 E.1 General . 53 E.2 Test apparatus . 53 E.3 Test setup 53 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation . 56 Bibliography . 66 DIN EN 54-28:2016-07EN 54-28:2016 (E) 4 European foreword This document (EN
24、 54-28:2016) has been prepared by Technical Committee CEN/TC 72 “Fire detection and fire alarm systems”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by Au
25、gust 2016, and conflicting national standards shall be withdrawn at the latest by February 2020. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such pate
26、nt rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports the basic requirements of Regulation (EU) 305/2011. For relationship with EU Regulations, see informative Annex ZA which is an integral part of thi
27、s document. EN 54, Fire detection and fire alarm systems consists of the following parts: Part 1: Introduction Part 2: Control and indicating equipment Part 3: Fire alarm devices Sounders Part 4: Power supply equipment Part 5: Heat detectors Point detectors Part 7: Smoke detectors Point detectors us
28、ing scattered light, transmitted light or ionization Part 10: Flame detectors Point detectors Part 11: Manual call points Part 12: Smoke detectors Line detectors using an optical beam Part 13: Compatibility assessment of system components Part 14: Guidelines for planning, design, installation, commi
29、ssioning, use and maintenance Part 15: Point detectors using a combination of detected phenomena Part 16: Voice alarm control and indicating equipment Part 17: Short-circuit isolators Part 18: Input/output devices Part 20: Aspirating smoke detectors DIN EN 54-28:2016-07EN 54-28:2016 (E) 5 Part 21: A
30、larm transmission and fault warning routing equipment Part 22: Resettable line-type heat detectors Part 23: Fire alarm devices Visual alarm devices Part 24: Components of voice alarm systems Loudspeakers Part 25: Components using radio links Part 26: Carbon monoxide detectors Point detectors Part 27
31、: Duct smoke detectors Part 28: Non-resettable line-type heat detectors Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors Part 30: Multi-sensor fire detectors - Point detectors using a combination of carbon monoxide and heat sensors Part 31: Multi-s
32、ensor fire detectors Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors Part 32: Guidelines for the planning, design, installation, commissioning, use and maintenance of voice alarm systems NOTE This list includes standards that are in preparation and other sta
33、ndards may be added. For current status of published standards refer to www.cen.eu. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Rep
34、ublic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN
35、 EN 54-28:2016-07 EN 54-28:2016 (E) 6 Introduction Non-resettable line-type heat detectors (NLTHD) have been used for a considerable number of years and are incorporated into fire detection systems and in some countries even into fire alarm systems if accepted by the relevant authorities. These dete
36、ctors are typically used in areas where point type heat detectors are presented with challenging environmental characteristics and also, where access to the detectors, may significantly influence the fire alarm system design. This standard defines the minimum system functionality for NLTHD products.
37、 Due to the various applications for NLTHD, it is necessary to devise separate environmental classification tests for the sensing element and the sensor control units of these systems. It is not the purpose of this standard to define applications or how NLTHD should be used in applications. Generall
38、y NLTHD operate on using the same basic principle. However, they can have different performance with respect to the temperature response. Therefore they have been differentiated by a type code which reflects the nominal alarm temperature, the tolerance range and the maximum ambient temperature at wh
39、ich they could be used. DIN EN 54-28:2016-07 EN 54-28:2016 (E) 7 1 Scope This European Standard applies to non-resettable line-type heat detectors consisting of a sensing element using an electrical sensor cable which can be connected to a sensor control unit or either directly or through an interfa
40、ce module to a control and indicating equipment intended for use in fire detection and fire alarm systems installed in and around buildings and civil engineering works (see EN 54-1:2011). The non-resettable sensing element has a fixed temperature alarm threshold and does not distinguish between shor
41、t circuit and alarm condition. This European Standard specifies the requirements and performance criteria, the corresponding test methods and provides for the Assessment and Verification of Constancy of Performance (AVCP) of non-resettable line-type heat detectors to this European Standard. This Eur
42、opean Standard also covers non-resettable line-type heat detectors intended for use in the local protection of plant and equipment. Non-resettable line-type heat detectors with special characteristics and developed for specific risks are not covered by this standard. 2 Normative references The follo
43、wing documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 54-1:2011, Fi
44、re detection and fire alarm systems - Part 1: Introduction EN 50130-4:2011, Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems EN 60068-1:2014, Environmental t
45、esting - Part 1: General and guidance (IEC 60068-1:2013) EN 60068-2-1:2007, Environmental testing - Part 2-1: Tests - Test A: Cold (IEC 60068-2-1:2007) EN 60068-2-2:2007, Environmental testing - Part 2-2: Tests - Test B: Dry heat (IEC 60068-2-2:2007) EN 60068-2-27:2009, Environmental testing - Part
46、2-27: Tests - Test Ea and guidance: Shock (IEC 60068-2-27:2009) EN 60068-2-30:2005, Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) (IEC 60068-2-30:2005) EN 60068-2-42:2003, Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contact
47、s and connections (IEC 60068-2-42:2003) EN 60068-2-6:2008, Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) (IEC 60068-2-6:2008) EN 60068-2-75:1997, Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests (IEC 60068-2-75:1997) EN 60068-2-78:2013, Environmental testi
48、ng - Part 2-78: Tests - Test Cab: Damp heat, steady state (IEC 60068-2-78:2012) DIN EN 54-28:2016-07EN 54-28:2016 (E) 8 3 Terms, definitions and abbreviations For the purposes of this document, the terms and definitions given in EN 54-1:2011 and the following apply. 3.1 Terms and definitions 3.1.1 d
49、igital detector detectors, the sensing element of which can be either of two states: standby or alarm Note 1 to entry: In this type of detector the alarm threshold is inherent to the construction of the sensing element. 3.1.2 functional unit part of a line-type heat detector in addition to the sensor control unit and the sensing element which is essential for the function of the line-type heat detector EX