DLA AN3306 REV 7-2013 RELAY 10 AMP 2 PDT SEALED CONNECTOR MOUNTING CLASS O.pdf

上传人:sumcourage256 文档编号:688206 上传时间:2018-12-30 格式:PDF 页数:5 大小:52.96KB
下载 相关 举报
DLA AN3306 REV 7-2013 RELAY 10 AMP 2 PDT SEALED CONNECTOR MOUNTING CLASS O.pdf_第1页
第1页 / 共5页
DLA AN3306 REV 7-2013 RELAY 10 AMP 2 PDT SEALED CONNECTOR MOUNTING CLASS O.pdf_第2页
第2页 / 共5页
DLA AN3306 REV 7-2013 RELAY 10 AMP 2 PDT SEALED CONNECTOR MOUNTING CLASS O.pdf_第3页
第3页 / 共5页
DLA AN3306 REV 7-2013 RELAY 10 AMP 2 PDT SEALED CONNECTOR MOUNTING CLASS O.pdf_第4页
第4页 / 共5页
DLA AN3306 REV 7-2013 RELAY 10 AMP 2 PDT SEALED CONNECTOR MOUNTING CLASS O.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AMSC N/A FSC 5945 AN3306 REVISION 7 31 January 2013 SUPERSEDING REVISION 6 1 February 2006 DETAIL SPECIFICATION SHEET RELAY, 10 AMP, 2 PDT, SEALED, CONNECTOR MOUNTING, CLASS O Inactive for new design after 17 November 1954. No superseding document. This specification is approved for use by all Depa

2、rtments and Agencies of the Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification and the latest issue of MIL-PRF-6106. FIGURE 1. Configurations and dimensions. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permit

3、ted without license from IHS-,-,-AN3306 REVISION 7 2 Inches mm .016 0.406 1.813 46.050 2.563 65.100 3.563 90.500 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerances are .016 (0.406 mm). FIGURE 1. Configurations a

4、nd dimensions - Continued. REQUIREMENTS Operating cycles: 50,000 minimum. Contact data: Contact voltage drop: Initial: 0.150 volt maximum. Applicable only for AN3306-2. After life: 0.175 maximum. Applicable only for AN3306-2. Load ratings: See Table I. TABLE I - Rated contact load (per pole). Type o

5、f load Amperes Resistive (DC) 10 Resistive (AC 400 Hz, 115 volts) 10 Inductive 10Motor 6 Overload current: See MIL-PRF-6106. Not applicable to AN3306-1. Rupture current: See MIL-PRF-6106. Not applicable AN3306-1. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr

6、om IHS-,-,-AN3306 REVISION 7 3 Coil data: Nominal coil voltage: 28 volts. Maximum operating voltage: 29 volts. Pickup voltage: 18 volts. Hold voltage: 7 volts Dropout voltage: 1.5 volts. Rated duty: Continuous. Coil current: 0.35 amperes, maximum. Physical data: Weight: 0.5 pounds, maximum. Qualific

7、ation by similarity: See MIL-PRF-6106. Retention of qualification: To retain qualification, the manufacturer shall submit group A acceptance reports on a yearly basis to the qualifying activity. Dielectric strength: Sea level (V rms) Altitude (V rms) Initial After life 80,000 feet -1 -2 1,000 1,000

8、250 500 1,250 1,000 250 500 Environmental requirements: Temperature range: -65 C to +120 C. Shock (specified pulse): Applicable, MIL-STD-202, method 213, test condition A, 25 gs, 6-9 milliseconds. Contact chatter shall not exceed 10 milliseconds maximum opening for closed contacts and 1 microsecond

9、maximum closure for open contacts. Vibration (sinusoidal): Applicable, MIL-STD-202, method 204, test condition A, + 10 gs or .036 DA whichever is less from 5 to 500 Hz. Contact chatter shall not exceed 10 microseconds maximum opening for closed contacts and 1 microsecond maximum closure for open con

10、tacts. Hermetically-sealed (potted) relay: Relays shall be tested as follows: a. Prior to installing a gasket on the relay header (if a gasket is used), the relay shall be totally immersed in a container of “tap” water. (The “tap” water as used here means ordinary drinking water that has not been al

11、tered in any way, such as by the addition of any other substance, distilling, etc.) The part of the relay closest to the surface of the water shall be a minimum of 1 inch (25.4 mm) below this surface. Coil to case: All of the points: Provided by IHSNot for ResaleNo reproduction or networking permitt

12、ed without license from IHS-,-,-AN3306 REVISION 7 4 b. The container and water-cover relay shall then be placed in a vacuum chamber. The chamber shall be sealed. The chamber pressure shall be reduced from room ambient to 0.82 inch (80,000 feet) +0.0 inch -0.2 inch of mercury within 5 minutes, and sh

13、all be maintained at this level for 30 minutes minimum. The chamber pressure shall be increased to room ambient within 1 minute, and shall be maintained at room ambient pressure for 30 minutes, minimum. The foregoing shall constitute open cycle. The relay shall remain fully immersed in the water dur

14、ing the cycle. c. Within a maximum of one-half hour after the cycle, each relay shall be removed from the water and dried by shaking, wiping, or blowing with contaminant-free air or gas, but not by any form of heating or baking. d. Within a maximum of one-half hour after drying, each relay shall be

15、subject to the DWV and IR tests. Life test requirement 50,000 cycles minimum. Qualification by similarity: If the relay case, frame, or enclosure contains integral sealed electromagnetic relays (mounting means excepted) currently listed on the qualified products list of MIL-PRF-83536/32, reduced tes

16、ting shall consist of subjecting four sample units to the shock and vibration requirements of this specification sheet. Post tests shall include insulation resistance, dielectric withstanding voltage and electrical characteristics, and seal. One unsealed unpotted unit shall be submitted to the quali

17、fying activity. VERIFICATION: Group A. a. Group A1: Run-in. This subgroup may be waived by the qualifying activity if fully tested sealed MIL-PRF-83536/32 relays are used internally. b. Group A2: 100 percent. c. Dielectric withstanding voltage: (1)Tests to be conducted at sea level rating only. (2)D

18、uration of application: 5-10 seconds at a 10 percent increase in the dielectric strength voltage. Group A acceptance reports shall be submitted to the qualifying activity on a yearly basis in order to retain qualification for this detail specification sheet. Group B and group C testing are not requi

19、red. The manufacturer shall notify the qualifying activity in the event of any design or construction changes, and the qualifying activity may impose additional testing requirements as necessary. Part or Identifying Number (PIN): AN3306-1 and AN3306-2. NOTES: AN3306-2 relays shall meet the mixed loa

20、ds current requirements specified in MIL-PRF-6106. The relay shall be equipped with a glass to metal sealed electrical connector. Supersession information: Supersedes USAF Drawing 50B6186. Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where

21、 changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of

22、the marginal notations and relationship to the last previous issue. Referenced documents. In addition to MIL-PRF-6106, this document references the following: MIL-STD-202 MIL-PRF-83536/32 SAE-AS31021 SAE-AS31001 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro

23、m IHS-,-,-AN3306 REVISION 7 5 Custodians: Preparing activity: Army - AV DLA - CC Air Force - 85 DLA - CC (Project 5945-2013-003)Review activity: Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • CAN CSA-C22 2 NO 60335-2-23-2015 Household and similar electrical appliances - Safety - Part 2-23 Particular requirements for appliances for skin or hair care (Third Edition).pdf CAN CSA-C22 2 NO 60335-2-23-2015 Household and similar electrical appliances - Safety - Part 2-23 Particular requirements for appliances for skin or hair care (Third Edition).pdf
  • CAN CSA-C22 2 NO 60335-2-24-2006 Safety Requirements for Household and Similar Electrical Appliances Part 2 Particular Requirements for Refrigerating Appliances Ice-Cream Appliance.pdf CAN CSA-C22 2 NO 60335-2-24-2006 Safety Requirements for Household and Similar Electrical Appliances Part 2 Particular Requirements for Refrigerating Appliances Ice-Cream Appliance.pdf
  • CAN CSA-C22 2 NO 60335-2-34-2013 Safety of Household and Similar Electrical Appliances - Part 2-34 Particular Requirements for Motor-Compressors (First Edition).pdf CAN CSA-C22 2 NO 60335-2-34-2013 Safety of Household and Similar Electrical Appliances - Part 2-34 Particular Requirements for Motor-Compressors (First Edition).pdf
  • CAN CSA-C22 2 NO 60335-2-44-2014 Household and similar electrical appliances - Safety - Part 2-44 Particular requirements for ironers (First Edition).pdf CAN CSA-C22 2 NO 60335-2-44-2014 Household and similar electrical appliances - Safety - Part 2-44 Particular requirements for ironers (First Edition).pdf
  • CAN CSA-C22 2 NO 60335-2-45-2014 Household and similar electrical appliances - Safety - Part 2-45 Particular requirements for portable heating tools and similar appliances (First E.pdf CAN CSA-C22 2 NO 60335-2-45-2014 Household and similar electrical appliances - Safety - Part 2-45 Particular requirements for portable heating tools and similar appliances (First E.pdf
  • CAN CSA-C22 2 NO 60335-2-52-2014 Household and similar electrical appliances - Safety - Part 2-52 Particular requirements for oral hygiene appliances (First Edition).pdf CAN CSA-C22 2 NO 60335-2-52-2014 Household and similar electrical appliances - Safety - Part 2-52 Particular requirements for oral hygiene appliances (First Edition).pdf
  • CAN CSA-C22 2 NO 60335-2-55-2015 Household and similar electrical appliances - Safety - Part 2-55 Particular requirements for electrical appliances for use with aquariums and garde.pdf CAN CSA-C22 2 NO 60335-2-55-2015 Household and similar electrical appliances - Safety - Part 2-55 Particular requirements for electrical appliances for use with aquariums and garde.pdf
  • CAN CSA-C22 2 NO 60335-2-56-2015 Household and similar electrical appliances - Safety - Part 2-56 Particular requirements for projectors and similar appliances (Third Edition).pdf CAN CSA-C22 2 NO 60335-2-56-2015 Household and similar electrical appliances - Safety - Part 2-56 Particular requirements for projectors and similar appliances (Third Edition).pdf
  • CAN CSA-C22 2 NO 60335-2-78-2014 Household and similar electrical appliances - Safety - Part 2-78 Particular requirements for outdoor barbecues (First Edition).pdf CAN CSA-C22 2 NO 60335-2-78-2014 Household and similar electrical appliances - Safety - Part 2-78 Particular requirements for outdoor barbecues (First Edition).pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1