DLA MIL-DTL-22438 1 C-2012 PANEL RECEPTACLE ELECTRICAL AND ELECTRONIC (SYMBOL NO 754 2).pdf

上传人:figureissue185 文档编号:690128 上传时间:2018-12-30 格式:PDF 页数:4 大小:78.77KB
下载 相关 举报
DLA MIL-DTL-22438 1 C-2012 PANEL RECEPTACLE ELECTRICAL AND ELECTRONIC (SYMBOL NO 754 2).pdf_第1页
第1页 / 共4页
DLA MIL-DTL-22438 1 C-2012 PANEL RECEPTACLE ELECTRICAL AND ELECTRONIC (SYMBOL NO 754 2).pdf_第2页
第2页 / 共4页
DLA MIL-DTL-22438 1 C-2012 PANEL RECEPTACLE ELECTRICAL AND ELECTRONIC (SYMBOL NO 754 2).pdf_第3页
第3页 / 共4页
DLA MIL-DTL-22438 1 C-2012 PANEL RECEPTACLE ELECTRICAL AND ELECTRONIC (SYMBOL NO 754 2).pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 6110 MIL-DTL-22438/1C 03 May 2012 SUPERSEDING MIL-P-22438/1B 21 May 1980 DETAIL SPECIFICATION SHEET PANEL, RECEPTACLE, ELECTRICAL AND ELECTRONIC (SYMBOL NO. 754.2) This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for a

2、cquiring the product described herein shall consist of this specification sheet and MIL-DTL-22438. FIGURE 1. Panel receptacle, electrical and electronic. INCH-POUND INACTIVE FOR NEW DESIGN AFTER 18 July 1997 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH

3、S-,-,-MIL-DTL-22438/1C 2 Ltr Inches mm Min Max Min Max A 15.859 15.891 402.819 403.631 B 1.980 2.016 50.292 51.206 C 7.859 7.891 199.619 200.431 D .422 .454 10.719 11.532 E 4.984 5.016 126.594 127.406 F 3.484 3.516 88.494 89.306 G .265 .297 6.731 7.544 NOTES: 1. Dimensions are in inches. 2. Metric e

4、quivalents are given for general information only. 3. Unless otherwise specified, tolerances are plus or minus .016 inch (0.406 mm). FIGURE 1. Panel receptacle, electrical and electronic - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI

5、L-DTL-22438/1C 3 FIGURE 2. Wiring diagram. REQUIREMENTS: Interface and physical dimensions: See figures 1 and 2. Panel material: Steel, 12 gage. Mounting: Designed for mounting in an electrical and electronic test and maintenance table. Electrical: Bus connection terminal posts: All split-bolt type.

6、 DC circuit posts shall aaccept maximum wire size AWG-2. AC and ground circuit posts shall accept maximum wire size AWG-8. Interior wiring: Type D-12 in accordance with MIL-DTL-16878/3. Part or Identifying Number (PIN): The PIN shall be M22438/1-001. Referenced documents. In addition to MIL-DTL-2243

7、8, this document references the following: MIL-DTL-16878/3 The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in thes

8、e notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from I

9、HS-,-,-MIL-DTL-22438/1C 4 Custodians: Preparing activity: Navy - SH DLA - CC DLA - CC (Project 6110-2012-003) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 61850-7-1-2012 Communication networks and systems for power utility automation - Part 7-1 Basic communication structure - Principles and models (IEC 61850-7-1 2011) English .pdf DIN EN 61850-7-1-2012 Communication networks and systems for power utility automation - Part 7-1 Basic communication structure - Principles and models (IEC 61850-7-1 2011) English .pdf
  • DIN EN 61850-7-2-2011 Communication networks and systems for power utility automation - Part 7-2 Basic information and communication structure - Abstract communication service inte.pdf DIN EN 61850-7-2-2011 Communication networks and systems for power utility automation - Part 7-2 Basic information and communication structure - Abstract communication service inte.pdf
  • DIN EN 61850-7-3-2011 Communication networks and systems for power utility automation - Part 7-3 Basic communication structure - Common data classes (IEC 61850-7-3 2010) English ve.pdf DIN EN 61850-7-3-2011 Communication networks and systems for power utility automation - Part 7-3 Basic communication structure - Common data classes (IEC 61850-7-3 2010) English ve.pdf
  • DIN EN 61850-7-4-2010 Communication networks and systems for power utility automation - Part 7-4 Basic communication structure - Compatible logical node classes and data object cla.pdf DIN EN 61850-7-4-2010 Communication networks and systems for power utility automation - Part 7-4 Basic communication structure - Compatible logical node classes and data object cla.pdf
  • DIN EN 61850-7-410-2013 Communication networks and systems for power utility automation - Part 7-410 Basic communication structure - Hydroelectric power plants - Communication for .pdf DIN EN 61850-7-410-2013 Communication networks and systems for power utility automation - Part 7-410 Basic communication structure - Hydroelectric power plants - Communication for .pdf
  • DIN EN 61850-7-420-2009 Communication networks and systems for power utility automation - Part 7-420 Basic communication structure - Distributed energy resources logical nodes (IEC.pdf DIN EN 61850-7-420-2009 Communication networks and systems for power utility automation - Part 7-420 Basic communication structure - Distributed energy resources logical nodes (IEC.pdf
  • DIN EN 61850-8-1-2012 Communication networks and systems for power utility automation - Part 8-1 Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO.pdf DIN EN 61850-8-1-2012 Communication networks and systems for power utility automation - Part 8-1 Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO.pdf
  • DIN EN 61850-9-1-2004 Communication networks and systems in substations - Part 9-1 Specific communication service mapping (SCSM) - Sampled values over serial unidirectional multidr.pdf DIN EN 61850-9-1-2004 Communication networks and systems in substations - Part 9-1 Specific communication service mapping (SCSM) - Sampled values over serial unidirectional multidr.pdf
  • DIN EN 61850-9-2-2012 Communication networks and systems for power utility automation - Part 9-2 Specific communication service mapping (SCSM) - Sampled values over ISO IEC 8802-3 .pdf DIN EN 61850-9-2-2012 Communication networks and systems for power utility automation - Part 9-2 Specific communication service mapping (SCSM) - Sampled values over ISO IEC 8802-3 .pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1