EN 14529-2005 en Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governe.pdf

上传人:ownview251 文档编号:714251 上传时间:2019-01-04 格式:PDF 页数:32 大小:337.52KB
下载 相关 举报
EN 14529-2005 en Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governe.pdf_第1页
第1页 / 共32页
EN 14529-2005 en Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governe.pdf_第2页
第2页 / 共32页
EN 14529-2005 en Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governe.pdf_第3页
第3页 / 共32页
EN 14529-2005 en Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governe.pdf_第4页
第4页 / 共32页
EN 14529-2005 en Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governe.pdf_第5页
第5页 / 共32页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN14529:2005Respiratory protective devices Self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governed demand valve for escape purposes onlyThe European Standard EN 14529:2005 has the status of a British Stand

2、ardICS 13.340.30g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 14529:2005This British Standard was published under the authority of the Stand

3、ards Policy and Strategy Committee on 31 May 2006 BSI 2006ISBN 0 580 46889 5National forewordThis British Standard is the official English language version of EN 14529:2005.The UK participation in its preparation was entrusted by Technical Committee PH/4, Respiratory protection, to Subcommittee PH/4

4、/13, Breathing apparatus, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in th

5、e BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible f

6、or its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK intere

7、sts informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document comprises a front cover, an inside front cover, page i, a blank page, the EN title page, pages 2 to 26, an inside back cover and a back cover.The BSI copyright notice dis

8、played in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsBS EN 14529:2005iWARNINGThe UK, as a member of CEN, is obliged to publish EN 14529:2005 as a British Standard. However, attention is drawn to the fact that during the developm

9、ent of this European Standard, the UK consistently voted against its approval as a European Standard.The reason for this disapproval is as follows. The Scope of EN 14529:2005 states that this standard “. . . specifies minimum requirements for self-contained open-circuit compressed air breathing appa

10、ratus with half mask designed to include a positive pressure lung governed demand valve for escape purposes only.“Such equipment is intended for use in work situations where the risk on overpressurisation of the pressure vessels with their valves due to hot environmental conditions is low.“This Euro

11、pean Standard does not apply to apparatus for work and rescue or to diving apparatus.”During discussion of this standard by BSI Committee PH/4/13, which mirrors the work of CEN Committee TC79/SC6, the UK committee expressed the opinion that the self-contained open-circuit compressed air breathing ap

12、paratus with half mask covered in this standard is not a safe combination to be used in those emergency situations where wearers may be exposed to other conditions (such as exposure in confined spaces to, or leaks of, noxious or toxic substances) that will, on the basis of a risk assessment in accor

13、dance with The Control of Substances Hazardous to Health Regulations 2002, require the combination to meet higher minimum performance requirements for the protection of the wearer.blankEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14529August 2005ICS 13.340.30English VersionRespiratory protectiv

14、e devices - Self-contained open-circuitcompressed air breathing apparatus with half mask designed toinclude a positive pressure lung governed demand valve forescape purposes onlyAppareils de protection respiratoire - Appareils deprotection respiratoire autonomes circuit ouvert, aircomprim avec demi-

15、masque et soupape la demande commande la premire inspiration, pression positive,pour lvacuation uniquementAtemschutzgerte - Behltergerte mit Druckluft(Pressluftatmer) mit Halbmaske in der Ausfhrung miteinem berdrucklungenautomaten nur fr FluchtzweckeThis European Standard was approved by CEN on 1 Ju

16、ly 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtaine

17、d on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretari

18、at has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,

19、Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any form and by any means reservedworldwide

20、 for CEN national Members.Ref. No. EN 14529:2005: EEN 14529:2005 (E) 2 Contents Page Foreword 3 Introduction4 1 Scope .5 2 Normative references .5 3 Terms and definitions.6 4 Description 6 5 Classification.6 6 Requirements 6 7 Testing .13 8 Marking 17 9 Information supplied by the manufacturer18 Ann

21、ex A (informative) Methods of measurement of the insulation resistance of the carrying container21 Annex B (informative) Marking 24 Annex ZA (informative) Clauses of this European Standard addressing essential requirements or other provisions of EU Directives25 Annex ZB (informative) Relationship be

22、tween this European Standard and the Essential Requirements of EU Directive 97/23/EC (PED) .26 EN 14529:2005 (E) 3 Foreword This European Standard (EN 14529:2005) has been prepared by Technical Committee CEN/TC 79 “Respiratory protective devices”, the secretariat of which is held by DIN. This Europe

23、an Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2006, and conflicting national standards shall be withdrawn at the latest by April 2006. This European Standard has been prepared under a mandate given t

24、o CEN/CENELEC by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s) 89/686/EEC and 97/23/EEC. For relationship with EU Directive(s), see informative Annexes ZA and ZB, which are integral parts of this European Standard. According t

25、o the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Lu

26、xembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 14529:2005 (E) 4 Introduction A given respiratory protective device can only be approved when the individual components satisfy the requirements of the test specification whi

27、ch may be a complete European Standard or part of a European Standard and practical performance tests have been carried out successfully on complete apparatus where specified in the appropriate European Standard. If for any reason a complete apparatus is not tested then simulation of the apparatus i

28、s permitted provided the respiratory characteristics and weight distribution are similar to those of the complete apparatus. EN 14529:2005 (E) 5 1 Scope This European Standard specifies minimum requirements for self-contained open-circuit compressed air breathing apparatus with half mask designed to

29、 include a positive pressure lung governed demand valve for escape purposes only. Such equipment is intended for use in work situations where the risk on overpressurisation of the pressure vessels with their valves due to hot environmental conditions is low. This European Standard does not apply to

30、apparatus for work and rescue or to diving apparatus. Laboratory and practical performance tests are included for the assessment of compliance with the requirements. 2 Normative references The following referenced documents are indispensable for the application of this European Standard. For dated r

31、eferences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 132:1998, Respiratory protective devices Definitions of terms and pictograms EN 134:1998, Respiratory protective devices - Nomenclature of component

32、s EN 140:1998, Respiratory protective devices Half mask and quarter masks Requirements, testing, marking EN 148-1, Respiratory protective devices - Threads for facepieces - Part 1: Standard thread connection EN 148-2, Respiratory protective devices - Threads for facepieces - Part 2: Centre thread co

33、nnection EN 148-3, Respiratory protective devices - Threads for facepieces - Part 3: Thread connection for M 45 x 3 EN 1964-1, Transportable gas cylinders Specification for the design and construction of refillable transportable seamless steel gas cylinders of water capacities from 0,5 litre up to a

34、nd including 150 litres Part 1: Cylinders made of seamless steel with an Rmvalue of less than 1100 MPa EN 1964-2, Transportable gas cylinders Specification for the design and construction of refillable transportable seamless steel gas cylinders of water capacities from 0,5 litre up to and including

35、150 litres Part 2: Cylinders made of seamless steel with an Rmvalue of 1100 MPa and above EN 1964-3, Transportable gas cylinders Specification for the design and construction of refillable transportable seamless steel gas cylinders of water capacity from 0,5 litre up to and including 150 litres Part

36、 3: Cylinders made of seamless stainless steel with an Rmvalue of less than 1100 MPa EN 1975, Transportable gas cylinders - Specification for the design and construction of refillable transportable seamless aluminium and aluminium alloy gas cylinders of capacity from 0, 5 litre up to 150 litre EN 12

37、021, Respiratory protective devices - Compressed air for breathing apparatus EN 12245, Transportable gas cylinders - Fully wrapped composite cylinders EN 13274-2:2001, Respiratory protective devices - Methods of test - Part 2: Practical performance tests EN 13274-3:2001, Respiratory protective devic

38、es - Methods of test - Part 3: Determination of breathing resistance EN 14529:2005 (E) 6 EN 13274-4:2001, Respiratory protective devices - Methods of test - Part 4: Flame tests EN 13274-5, Respiratory protective devices - Methods of test - Part 5: Climatic conditions 3 Terms and definitions For the

39、purposes of this European Standard, the terms and definitions given in EN 132:1998 and the nomenclature given in EN 134:1998 apply. 4 Description Lung governed demand compressed air escape apparatus are designed and constructed to enable the wearer to breathe air on demand from a pressure vessel(s)

40、either via a pressure reducer and a lung governed demand valve or a lung governed demand valve connected to the half mask. The exhaled air passes without re-circulation from the half mask via the exhalation valve to the ambient atmosphere. This apparatus typically comprises pressure vessel(s), body

41、harness, lung governed demand valve, pressure indicator(s), warning device (optional), connecting hoses and tubes and a half mask. 5 Classification Lung governed demand compressed air escape apparatus are classified according to the rated working duration (see 6.23.1) which is defined by performing

42、a breathing machine test in accordance with 7.6.4 with a minute volume of 35 l/min (20 cycles/min, 1,75 l/stroke). Rated working duration is defined in steps of 5 minutes, starting with 5 minutes as a minimum, up to a maximum of 30 min rated working duration, since the necessary escape time is consi

43、dered to be the classification. NOTE It should be recognised that the effective duration may vary according to the breathing rate. 6 Requirements 6.1 General In all tests all test samples shall meet the requirements. Wherever a test clause is referenced, all sub-clauses of the test clause shall appl

44、y, unless otherwise stated. 6.2 Ergonomics The requirements of this European Standard are intended to take account of the interaction between the wearer, the apparatus, and where possible the working environment in which the apparatus is likely to be used. The device shall satisfy 6.3, 6.8 and 6.9.

45、6.3 Design The diameter of pressurised parts downstream of the shut-off valve(s) shall not exceed 32 mm. The apparatus shall be designed so as not to interfere with work activities when carried in accordance with the manufacturers instructions. The apparatus shall be so designed that there are no pr

46、otruding parts or sharp edges likely to be caught on projections in narrow passages or that may hurt the wearer. EN 14529:2005 (E) 7 The apparatus shall be designed to ensure its full function in any orientation. The ready for use state of the apparatus shall identify the pressure in the pressure ve

47、ssel(s) prior to use and during storage. In the ready for use state the half mask shall be securely attached to the apparatus. In the case of a permanent installation of the apparatus in a storage container the pressure vessel seal shall be opened automatically upon removal from the storage containe

48、r. In all cases, once opened, the pressure vessel seal shall be locked in the open position against inadvertent closing. If the escape apparatus is fitted with a connection for a working breathing apparatus, (e.g. airline apparatus), the connection shall be leak tight. The use of a supplementary sup

49、ply shall not be permitted. The apparatus shall not include a second medium pressure connector or an ambient air bypass. Testing shall be done in accordance with 7.3 and 7.8. 6.4 Materials The carrying container and the locking device, where present, shall be adequately protected against corrosion. The materials used shall be able to withstand temperatures and mechanical stress expected whilst being carried on the man as well as on machines and vehicles. Testing shall be done in accordance with 7.3, and 7.8 after pre-conditioning according t