1、BRITISH STANDARDBS EN 15197:2007Wood-based panels Flaxboards SpecificationsThe European Standard EN 15197:2007 has the status of a British StandardICS 79.060.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44

2、g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 15197:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 March 2007 BSI 2007ISBN 978 0 580 50401 3National forewordThis British Standard was published by BSI. It is the UK

3、implementation of EN 15197:2007.The UK participation in its preparation was entrusted to Technical Committee B/541, Wood based panels.A list of organizations represented on B/541 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of

4、a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 15197February 2007ICS 79.060.20English VersionWood

5、-based panels - Flaxboards - SpecificationsPanneaux base de bois - Panneaux de lin - Spcifications Holzwerkstoffe - Flachsspanplatten - AnforderungenThis European Standard was approved by CEN on 13 January 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate

6、 the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists

7、in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies

8、of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN

9、COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15197:2007: EEN 15197:2007 (E) 2 Con

10、tents Page Foreword3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Classification5 5 General requirements6 6 Requirements for general purpose flaxboard for use in dry conditions (Type FB1).7 7 Requirements for non-load bearing flaxboard for use in dry conditions (Type FB2) .7 8 Req

11、uirements for flaxboard for interior fitments (including furniture) for use in dry conditions (Type FB3) .8 9 Requirements for non-load bearing flaxboard for use in humid conditions (Type FB4) .9 10 Supplementary properties 9 11 Verification of compliance 10 12 Marking .11 Bibliography 12 EN 15197:2

12、007 (E) 3 Foreword This document (EN 15197:2007) has been prepared by Technical Committee CEN/TC 112 “Wood-based panels”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at

13、 the latest by August 2007, and conflicting national standards shall be withdrawn at the latest by August 2007. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria

14、, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 15197:2007 (E) 4 1 Scope This Eu

15、ropean Standard specifies the requirements for flaxboards for general purposes, non-load bearing applications and interior fitments in dry conditions and for flaxboards for non-load bearing applications for use in humid conditions. NOTE 1 Dry conditions are defined in terms of service class 1 of EN

16、1995-1-1 which is characterized by the moisture content in the material corresponding to a temperature of 20 C and a relative humidity of the surrounding air only exceeding 65 % for a few weeks per year. Boards of this type are only suitable for use in biological hazard class 1 of EN 335-3. Humid co

17、nditions are defined in terms of service class 2 of EN 1995-1-1, which is characterised by a moisture content in the material corresponding to a temperature of 20 C and a relative humidity of the surrounding air only exceeding 85 % for a few weeks per year. NOTE 2 This standard will be referred to i

18、n EN 13986, as far as construction applications are concerned. NOTE 3 Boards in accordance with this standard may be referred to as FB1, FB2, FB3 or FB4 boards. The values listed in this standard relate to product properties but they are not characteristic values to be used for design calculations.

19、2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 120, Wood based panels

20、Determination of formaldehyde content Extraction method called the perforator method EN 310, Wood-based panels Determination of modulus of elasticity in bending and of bending strength EN 311, Wood-based panels Surface soundness Test method EN 317, Particleboards and fibreboards Determination of swe

21、lling in thickness after immersion in water EN 318, Wood based panels Determination of dimensional changes associated with changes in relative humidity EN 319, Particleboards and fibreboards Determination of tensile strength perpendicular to the plane of the board EN 322, Wood-based panels Determina

22、tion of moisture content EN 323, Wood-based panels Determination of density EN 324-1, Wood-based panels Determination of dimensions of boards Part 1: Determination of thickness, width and length EN 324-2, Wood-based panels Determination of dimensions of boards Part 2: Determination of squareness and

23、 edge straightness EN 326-1, Wood-based panels Sampling, cutting and inspection Part 1: Sampling and cutting of test pieces and expression of test results EN 326-2, Wood-based panels Sampling, cutting and inspection Part 2: Quality control in the factory EN 15197:2007 (E) 5 EN 326-3, Wood-based pane

24、ls Sampling, cutting and inspection Part 3: Inspection of an isolated lot of panels EN 717-1, Wood-based panels Determination of formaldehyde release Part 1: Formaldehyde emission by the chamber method EN 1087-1, Particleboards Determination of moisture resistance Part 1: Boil test EN 13986, Wood-ba

25、sed panels Wood-based panels for use in construction Characteristics, evaluation of conformity and marking ISO 3340, Fibre building boards Determination of sand content 3 Terms and definitions For the purposes of this document, the following term and definition applies. 3.1 flaxboard particleboard a

26、s defined in EN 309 manufactured under pressure and heat from flax shives, with the addition of an adhesive which contains at least 70 % flax and which can also contain other raw materials such as particles of wood (wood flakes, chips, shavings, saw dust and similar materials) 4 Classification Type

27、FB1 General purpose flaxboard for use in dry conditions (usually for filling purposes). Type FB2 Non-load bearing flaxboard for use in dry conditions (usually for further processing, such as veneering). Type FB3 Flaxboard for interior fitment (including furniture) for use in dry conditions. Type FB4

28、 Non-load bearing flaxboard for use in humid conditions. EN 15197:2007 (E) 6 5 General requirements Flaxboards shall comply with the general requirements listed in Table 1, when dispatched from the production. Table 1 General requirements at dispatch No Property Test method Requirement 1aTolerances

29、on nominal dimensions Thickness (sanded) within and between boards Thickness (unsanded) within and between boards Length and width EN 324-1 0,3 mm 0,3 mm + 1,7 mm 5 mm 2aEdge straightness tolerance EN 324-2 1,5 mm/m 3aSquareness tolerance EN 324-2 2 mm/m 4aMoisture content EN 322 5 % to 13 % 5aToler

30、ance on the mean density within a board EN 322 10 % 6bFormaldehyde Class E 1 Perforator value Steady state emission valuec EN 120 EN 717-1 Content 8 mg/100 g oven dry boardd Release 0,124 mg/m3air a These values are characterized by a moisture content in the material corresponding to a relative humi

31、dity of 65 % and a temperature of 20 C.b The perforator values apply to boards with moisture contents H of 6,5 %. In the case of particleboards with different moisture content (in the range of 3 % H 10 %) the perforator value shall be multiplied by a factor F which can be calculated from the followi

32、ng equation: F = 0,133 H + 1,86 c Required for initial type testing other than for established products where initial type testing may also be carried out on the basis of existing data with EN 120 or EN 717-1 testing, either from factory production control or from external inspection. d Experience h

33、as shown that to ensure compliance with these limits, the rolling average of the values of EN 120 found from the internal factory production control over a period of year should not exceed 6,5 mg HCHO/100 g panel mass.EN 15197:2007 (E) 7 6 Requirements for general purpose flaxboard for use in dry co

34、nditions (Type FB1) Boards of this type shall comply with the requirements given in Table 2. These requirements shall be met by five percentile values based on the mean values for individual boards and calculated in accordance with EN 326-1. These five percentile values shall be equal to or greater

35、than the values in Table 2. Table 2 General purpose flaxboards for use in dry conditions (Type FB1) Requirements for specified mechanical properties Requirement Thickness range (mm, nominal) Property Test method Unit 25 to 32 32 to 40 40 Bending strength EN 310 N/mm26,0 5,5 4,5 4,0 3,5 Internal bond

36、 EN 319 N/mm20,13 0,11 0,10 0,08 0,05 NOTE The values are characterised by moisture content in the material corresponding to a relative humidity of 65 % and a temperature of 20 C. 7 Requirements for non-load bearing flaxboard for use in dry conditions (Type FB2) Boards of this type shall comply with

37、 the requirements given in Table 3. These requirements shall be met by five percentile values based on the mean values for individual boards and calculated in accordance with EN 326-1. These five percentile values shall be equal to or greater than the values in Table 3. Table 3 Non load bearing flax

38、boards for use in dry conditions (Type FB2) Requirements for specified mechanical properties Requirement Thickness range (mm, nominal) Property Test method Unit 20 to 25 25 to 32 32 to 40 40 Bending strength EN 310 N/mm29,0 8,0 7,0 6,5 6,0 5,0 Modulus of elasticity EN 310 N/mm 1 500 1 350 1 200 1 05

39、0 1 000 950 Internal bond EN 319 N/mm20,23 0,20 0,18 0,15 0,13 0,10 NOTE The values are characterised by moisture content in the material corresponding to a relative humidity of 65 % and a temperature of 20 C. EN 15197:2007 (E) 8 8 Requirements for flaxboard for interior fitments (including furnitur

40、e) for use in dry conditions (Type FB3) Boards of this type shall comply with the requirements given in Table 4. These requirements shall be met by five percentile values based on the mean values for individual boards and calculated in accordance with EN 326-1. These five percentile values shall be

41、equal to or greater than the values in Table 4. Table 4 Flaxboards for interior fitments for use in dry conditions (Type FB3) Requirements for specified mechanical properties Requirement Thickness range (mm, nominal) Property Test method Unit 13 to 20 20 to 25 25 to 32 32 to 40 40 to 50 50 Bending s

42、trength EN 310 N/mm211,5 10,5 9,0 8,5 7,0 6,5 Modulus of elasticity in bending EN 310 N/mm 1 600 1 500 1 350 1 200 1 050 950 Internal bond EN 319 N/mm20,30 0,25 0,22 0,18 0,18 0,15 Surface soundness EN 311 N/mm 0,7 0,7 0,7 0,7 0,7 0,7 NOTE The values are characterised by moisture content in the mate

43、rial corresponding to a relative humidity of 65 % and a temperature of 20 C. EN 15197:2007 (E) 9 9 Requirements for non-load bearing flaxboard for use in humid conditions (Type FB4) Boards of this type shall comply with the requirements given in Table 5. These requirements shall be met by 5 percenti

44、le values based on the mean values for individual boards and calculated in accordance with EN 326-1. These 5 percentile values shall be equal to or greater than the values in Table 5. In case of thickness swelling they shall be equal or less than the values in Table 5. Table 5 Non load-bearing flaxb

45、oards for use in humid conditions (Type FB4) Requirements for specified mechanical and physical properties Requirement Thickness range (mm, nominal) Property Test method Unit 13 to 20 20 to 25 25 to 32 32 to 40 40 to 50 50 Bending strength EN 310 N/mm29,5 8,5 7,5 7,0 6,5 5,5 Modulus of elasticity in

46、 bending EN 310 N/mm 1 600 1 500 1 350 1 200 1 050 950 Internal bond EN 319 N/mm20,30 0,25 0,22 0,18 0,18 0,15 Swelling in thickness 24 h EN 317 % 8 8 8 8 8 8 Internal bond after boil test EN 1087-1 N/mm 0,07 0,07 0,06 0,06 0,05 0,05 NOTE The values are characterised by moisture content in the mater

47、ial corresponding to a relative humidity of 65 % and a temperature of 20 C. 10 Supplementary properties For certain applications, information on some of the properties listed in Table 6 may be required. Upon request, this information shall be supplied by the board manufacturer and in this case shall

48、 have been derived using the test methods listed in Table 6. Table 6 Supplementary properties and test methods Property Test method Density EN 323 Dimensional changes EN 318 Surface soundness EN 311 Swelling in thickness EN 317 Sand content ISO 3340 NOTE For certain applications, information on addi

49、tional properties not specified in Table 6 may be required. EN 15197:2007 (E) 10 11 Verification of compliance 11.1 General Verification of compliance with this standard shall be carried out using the test methods listed in Table 1 to Table 5. For boards for use in construction applications EN 13986 applies. 11.2 External control External control of the factory, if any, shall be carried out according to EN 326-2. Inspection of isolated lots shall be carried out accor