ETSI TS 101 116-1999 Digital cellular telecommunications system (Phase 2+) Specification of the 1 8 Volt Subscriber Identity Module - Mobile Equipment (SIM - ME) interface (Version.pdf

上传人:boatfragile160 文档编号:737662 上传时间:2019-01-12 格式:PDF 页数:11 大小:100.86KB
下载 相关 举报
ETSI TS 101 116-1999 Digital cellular telecommunications system (Phase 2+) Specification of the 1 8 Volt Subscriber Identity Module - Mobile Equipment (SIM - ME) interface (Version.pdf_第1页
第1页 / 共11页
ETSI TS 101 116-1999 Digital cellular telecommunications system (Phase 2+) Specification of the 1 8 Volt Subscriber Identity Module - Mobile Equipment (SIM - ME) interface (Version.pdf_第2页
第2页 / 共11页
ETSI TS 101 116-1999 Digital cellular telecommunications system (Phase 2+) Specification of the 1 8 Volt Subscriber Identity Module - Mobile Equipment (SIM - ME) interface (Version.pdf_第3页
第3页 / 共11页
ETSI TS 101 116-1999 Digital cellular telecommunications system (Phase 2+) Specification of the 1 8 Volt Subscriber Identity Module - Mobile Equipment (SIM - ME) interface (Version.pdf_第4页
第4页 / 共11页
ETSI TS 101 116-1999 Digital cellular telecommunications system (Phase 2+) Specification of the 1 8 Volt Subscriber Identity Module - Mobile Equipment (SIM - ME) interface (Version.pdf_第5页
第5页 / 共11页
点击查看更多>>
资源描述

1、ETSI TS 101 116 V7.0.1 (1999-07) Technical Specification Digital cellular telecommunications system (Phase 2+); Specification of the 1.8 Volt Subscriber Identity Module - Mobile Equipment (SIM - ME) interface (GSM 11.18 version 7.0.1 Release 1998) R GLOBAL SYSTEM FOR MOBILE COMMUNICATIONS (GSM 11.18

2、 version 7.0.1 Release 1998) 2 ETSI TS 101 116 V7.0.1 (1999-07)ETSIReference DTS/SMG-091118Q7 (ac003i0r.PDF) Keywords Digital cellular telecommunications system, Global System for Mobile communications (GSM) ETSI Postal address F-06921 Sophia Antipolis Cedex - FRANCE Office address 650 Route des Luc

3、ioles - Sophia Antipolis Valbonne - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Internet secretariatetsi.fr Individual copies of this ETSI deliverable can be downloaded

4、from http:/www.etsi.org If you find errors in the present document, send your comment to: editoretsi.fr Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunica

5、tions Standards Institute 1999. All rights reserved. (GSM 11.18 version 7.0.1 Release 1998) 3 ETSI TS 101 116 V7.0.1 (1999-07)ETSIContents Intellectual Property Rights4 Foreword 4 1 Scope 5 2 References 5 3 Definitions, abbreviations and symbols .5 3.1 Definitions . 5 3.2 Abbreviations. 5 3.3 Symbol

6、s . 6 4 1.8V technology .6 4.1 1.8V technology SIM . 6 4.2 1.8V technology impact . 6 4.3 1.8V technology SIM Identification 6 4.4 1.8V technology ME 7 4.5 1.8V Only ME 7 4.6 Activation and deactivation . 7 4.7 Supply voltage switching . 7 4.8 Cross compatibility 7 5 Electrical specifications of the

7、 SIM - ME interface.7 Annex A (informative): Change history .10 History 11 (GSM 11.18 version 7.0.1 Release 1998) 4 ETSI TS 101 116 V7.0.1 (1999-07)ETSIIntellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertain

8、ing to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available free of charge from the ETSI

9、 Secretariat. Latest updates are available on the ETSI Web server (http:/www.etsi.org/ipr). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in SR 000 314 (or the update

10、s on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Specification (TS) has been produced by the Special Mobile Group (SMG). The contents of the present document are subject to continuing work within SMG and may change following fo

11、rmal SMG approval. Should SMG modify the contents of the present document, it will then be republished by ETSI with an identifying change of release date and an increase in version number as follows: Version 7.x.y where: 7 indicates GSM Release 1998 of Phase 2+ x the second digit is incremented for

12、all changes of substance, i.e. technical enhancements, corrections, updates, etc. y the third digit is incremented when editorial only changes have been incorporated in the specification. (GSM 11.18 version 7.0.1 Release 1998) 5 ETSI TS 101 116 V7.0.1 (1999-07)ETSI1 Scope The present document define

13、s the aspects of the Subscriber Identity Module - Mobile Equipment (SIM - ME) interface which are based on 1.8V technology to be used in the Mobile Station (MS). It specifies the electrical and logical requirements necessary for the operation of the 1.8V SIM - ME interface where it differs from GSM

14、11.11 1. For all aspects of the SIM - ME interface which are not covered by the present document, GSM 11.11 1 applies. 2 References The following documents contain provisions which, through reference in this text, constitute provisions of the present document. References are either specific (identif

15、ied by date of publication, edition number, version number, etc.) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. A non-specific reference to an ETS shall also be taken to refer to later versions published as an

16、EN with the same number. For this Release 1998 document, references to GSM documents are for Release 1998 versions (version 7.x.y). 1 GSM 11.11: “Digital cellular telecommunications system (Phase 2+); Specification of the Subscriber Identity Module - Mobile Equipment (SIM - ME) interface“. 2 GSM 11.

17、12 (ETS 300 641): “Digital cellular telecommunications system (Phase 2); Specification of the 3V Subscriber Identity Module - Mobile Equipment (SIM - ME) interface“. 3 Definitions, abbreviations and symbols 3.1 Definitions For the purposes of the present document, the following definitions apply. 1.

18、8V technology SIM: A SIM operating at 1.8V 10% and 3V 10%. 1.8V technology ME: An ME operating the SIM - ME interface at 1.8V 10% according to the present document and 3V 10% according to GSM 11.12 2. 1.8V only ME: An ME only operating the SIM - ME interface at 1.8V 10% according to the present docu

19、ment. 3.2 Abbreviations For the purposes of the present document, the following abbreviations apply: ATR Answer To Reset CLK Clock IC Integrated Circuit I/O Input/Output ME Mobile Equipment MS Mobile Station RST Reset SIM Subscriber Identity Module (GSM 11.18 version 7.0.1 Release 1998) 6 ETSI TS 10

20、1 116 V7.0.1 (1999-07)ETSI3.3 Symbols For the purposes of the present document, the following symbols apply. tF fall time tR rise timeVIH Input Voltage (high) VIL Input Voltage (low) VOH Output Voltage (high) VOL Output Voltage (low) 4 1.8V technology 4.1 1.8V technology SIM The SIM shall operate on

21、 both 3V 10% according to GSM 11.12 2, and on 1.8V 10% according to the present document. If the ME supplies 3V to the SIM, both the ME and the SIM shall operate according to GSM 11.12 (ETS 300 641) 2. The logical operation of the 1.8V technology SIM shall be as defined in GSM 11.11 1. The 1.8V tech

22、nology SIM shall not give an ATR if operated at a supply voltage of 1.4V or below. A 1.8V technology SIM may operate at 5V. If the 1.8V technology SIM operates at 5V it shall meet the electrical specifications as defined in GSM 11.11 1. Clock stop mode shall be supported by the SIM. The SIM shall in

23、dicate “Clock Stop Allowed“ in the file characteristics of the status information as specified in GSM 11.11 1. 4.2 1.8V technology impact When supplied with the supply voltage as specified in the present document the SIM shall be operated with a clock frequency of 1 to 4 MHz. 4.3 1.8V technology SIM

24、 Identification The 1.8V technology SIM shall contain an identification. The identification is coded on bits 5-7 in byte 14 of the status information as follows: Table 0: SIM Supply Voltage Indication SIM Supply Voltage Bit 7 Bit 6 Bit 5 5V only SIM 0 (RFU) 10 (RFU) 10 (RFU) 13V Technology SIM 0 (RF

25、U) 10 (RFU) 11 1.8V Technology SIM 0 (RFU) 11 1 Future Class 1 1 1 NOTE 1 The bits marked (RFU) are set to 0 and reserved for future use in the SIMs. The coding schemes relies on the fact that RFU bits are set to 0. The procedure for deriving the identification bit shall be performed by the ME immed

26、iately after the Answer To Reset (ATR) and before issuing any other command. The procedure consists of the two commands “SELECT GSM“ and “STATUS/GET RESPONSE“ (GSM 11.18 version 7.0.1 Release 1998) 7 ETSI TS 101 116 V7.0.1 (1999-07)ETSI4.4 1.8V technology ME The 1.8V technology ME shall initially ac

27、tivate the SIM with 1.8V according to this specification. If the ME detects a 1.8V technology SIM, the ME may operate the SIM at 1.8V according to this specification. If the ME detects a 3V SIM, the ME shall switch to 3V operation as defined in GSM 11.12 2 using the procedure as defined in subclause

28、 4.7. If switching is performed, it shall take place before issuing any further commands as defined in paragraph 4.3. If a faulty ATR is received at 1.8V, the ME shall initiate the error handling procedure described in GSM 11.11 1 with the supply voltage remaining at 1.8V. If the error handling does

29、 not result in an errorless ATR, the ME shall activate the SIM at 3V. Activation at 3V shall be performed in accordance with GSM 11.12 2. If no ATR is received at 1.8V, the ME shall deactivate the SIM and activate it at 3V according to GSM 11.12 2. If a correct ATR is not received at 3V or the ME de

30、tects a 5V only SIM the ME shall reject the SIM without issuing any further commands. If a 1.8V technology ME detects a SIM that indicates a future class the ME shall not activate that SIM at 3V. 4.5 1.8V Only ME The 1.8V only ME activates the SIM at 1.8V. If the ME is able to detect a 3V technology

31、 SIM according to the procedure in subclause 4.3, or if the procedure cannot be completed, the ME shall deactivate and reject the SIM immediately (maximum of 5s) without issuing any further command. If an ATR is corrupted or not received by the ME, error handling according to sub clause 5.10 of GSM

32、11.11 1 shall apply. 4.6 Activation and deactivation The ME shall connect, activate and deactivate the SIM in accordance with the operating procedures specified in GSM 11.11 1 taking into account the electrical characteristics specified in clause 5 of the present document. In particular, Vcc is powe

33、red when it has a value between 1,62 V and 1,98 V. 4.7 Supply voltage switching MEs supporting both 1,8V and 3V operation may switch between the two supply voltages. Switching shall always be performed by deactivating the SIM and activating it at the new supply voltage. Activation and deactivation o

34、f the SIM with 3V shall be according to GSM 11.12 2, whereas activation and deactivation of the SIM with 1,8V shall be according to the present document. 4.8 Cross compatibility Cross compatibility means that the ME supports 1,8V and 3V operation. This is, however, optional for the ME. In case of th

35、e 1,8V technology ME, cross compatibility is provided, whereas, a 1,8V only ME requires a 1,8V technology SIM for operation. However, the 1,8V technology SIM (see definitions and subclause 4.1) ensures cross compatibility. 5 Electrical specifications of the SIM - ME interface The electrical specific

36、ation given in the present document covers the supply voltage range from 1,62V to 1,98V. The supply voltage range from 2,7V to 3,3V is specified in GSM 11.12 2. For each state (VOH, VIH, VIL and VOL) a positive current is defined as flowing out of the entity (ME or SIM) in that state. Vpp is not sup

37、ported by the 1,8V technology ME or the 1,8V technology SIM. (GSM 11.18 version 7.0.1 Release 1998) 8 ETSI TS 101 116 V7.0.1 (1999-07)ETSIWhen the SIM is in idle state the current consumption of the card shall not exceed 200 A at 1 MHz at +25C. When the SIM is in clock stop mode the current consumpt

38、ion shall not exceed 100 A at +25 C. The ME shall source the maximum current as defined in table 4. It shall also be able to counteract spikes in the current consumption of the card up to a maximum charge of 12 nAs with no more than 400 ns duration and an amplitude of at most 60 mA, ensuring that th

39、e supply voltage stays in the specified range. The clock duty cycle shall be between 40 % and 60 % of the period during stable operation. A clock cycle is defined at 50% of Vcc from rising to rising edge or falling to falling edge. When switching clock frequencies MEs shall ensure that no pulse is s

40、horter than 100 ns which is 40 % of the shortest allowed period. The ME need not provide contact C6 (Vpp). Contact C6 shall not be connected in the ME if provided. Table 1: Electrical characteristics of I/O under normal operating conditions Symbol Conditions Minimum Maximum Unit VIH IIHmax = 20 A (N

41、ote 2) 0,7 x Vcc Vcc+0,3 V VIL IILmax = + 1 mA - 0,3 0,2 x Vcc V VOH (Note 1) IOHmax = + 20 A 0,7 x Vcc Vcc (Note 3) V VOL IOLmax = - 1mA 0 (Note 3) 0,3 V tR tFCin = Cout = 30 pF 1 s NOTE 1: It is assumed that a pull-up resistor is used on the interface device (recommended value:20 k ). NOTE 2: Duri

42、ng static conditions (idle state) only the positive value can apply. Under dynamic operating conditions (transmissions) short term voltage spikes on the I/O line may cause a current reversal. NOTE 3: To allow for overshoot the voltage on I/O shall remain between -0,3V and Vcc+0,3V during dynamic ope

43、ration. Table 2: Electrical characteristics of Clock (CLK) under normal operating conditions Symbol Conditions Minimum Maximum Unit VOH IOHmax = + 20 A 0,7 x Vcc Vcc (Note ) V VOL IOLmax = - 20 A 0 (Note ) 0,2 x Vcc V tR tFCin = Cout = 30 pF 50 ns NOTE: To allow for overshoot the voltage on CLK shou

44、ld remain between -0,3V and Vcc+0,3V during dynamic operations. (GSM 11.18 version 7.0.1 Release 1998) 9 ETSI TS 101 116 V7.0.1 (1999-07)ETSITable 3: Electrical characteristics of RESET (RST) under normal operating conditions Symbol Conditions Minimum Maximum Unit VOH IOHmax = + 20 A 0,8 x Vcc Vcc (

45、Note) V VOL IOLmax = -200 A 0 (Note) 0,2 x Vcc V tR tFCin = Cout = 30 pF 400 s NOTE: To allow for overshoot the voltage on RST should remain between -0,3V and Vcc +0,3V during dynamic operations. Table 4: Electrical characteristics of Vcc under normal operating conditions Symbol Minimum Maximum Unit

46、 Vcc 1,62 1,98 V Icc 4 (Note) mA NOTE: The supply current at 1,8V refers to a clock frequency of 4 MHz. (GSM 11.18 version 7.0.1 Release 1998) 10 ETSI TS 101 116 V7.0.1 (1999-07)ETSIAnnex A (informative): Change history This annex lists all change requests approved for this document since the the pr

47、esent document was approved by ETSI SMG. SMG# SMG tdoc SMG9 tdoc VERS CR RV PH CAT SUBJECT Resulting Versions28 P-99-180 98p188 2.0.0 R98 Approval of final draft by SMG 7.0.0 (GSM 11.18 version 7.0.1 Release 1998) History 7.0.1 July 1999 tsBN 2-7437-3353-5 DepOt 1ega1 : Juillet 1999 Publication I I ETSI TS 101 116 V7.0.1 (1999n Document histoly

展开阅读全文
相关资源
猜你喜欢
  • ASD-STAN PREN 4695-2015 Aerospace series Tie rod with integrated bolts Assembly code G H and K (Edition P 2).pdf ASD-STAN PREN 4695-2015 Aerospace series Tie rod with integrated bolts Assembly code G H and K (Edition P 2).pdf
  • ASD-STAN PREN 4697-2014 Aerospace series General and installation requirements for passenger seat fittings (Edition P 2).pdf ASD-STAN PREN 4697-2014 Aerospace series General and installation requirements for passenger seat fittings (Edition P 2).pdf
  • ASD-STAN PREN 4700-001-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 001 Plate sheet and strip (Edition P 2)《航空航天系列 钢和耐热合金制锻件技.pdf ASD-STAN PREN 4700-001-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 001 Plate sheet and strip (Edition P 2)《航空航天系列 钢和耐热合金制锻件技.pdf
  • ASD-STAN PREN 4700-002-2014 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 002 Bar and section (Edition P 3).pdf ASD-STAN PREN 4700-002-2014 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 002 Bar and section (Edition P 3).pdf
  • ASD-STAN PREN 4700-003-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 003 Tube (Edition P 2)《航空航天系列 钢和耐热合金制锻件技术规范 第003部分 管材 第P2.pdf ASD-STAN PREN 4700-003-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 003 Tube (Edition P 2)《航空航天系列 钢和耐热合金制锻件技术规范 第003部分 管材 第P2.pdf
  • ASD-STAN PREN 4700-004-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 004 Wire (Edition P 2)《航空航天系列 钢和耐热合金锻件的技术规范 第004部分 线材 第P2.pdf ASD-STAN PREN 4700-004-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 004 Wire (Edition P 2)《航空航天系列 钢和耐热合金锻件的技术规范 第004部分 线材 第P2.pdf
  • ASD-STAN PREN 4700-005-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 005 Forging stock (Edition P 1)《航空航天系列 钢和耐热合金锻件的技术规范 第005.pdf ASD-STAN PREN 4700-005-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 005 Forging stock (Edition P 1)《航空航天系列 钢和耐热合金锻件的技术规范 第005.pdf
  • ASD-STAN PREN 4700-006-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 006 Pre-production and production forgings (Edition P 1)《.pdf ASD-STAN PREN 4700-006-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 006 Pre-production and production forgings (Edition P 1)《.pdf
  • ASD-STAN PREN 4700-007-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 007 Remelting stock (Edition P 1)《航空航天系列 钢和耐热合金锻件的技术规范 第0.pdf ASD-STAN PREN 4700-007-2009 Aerospace series Steel and heat resisting alloys Wrought products Technical specification Part 007 Remelting stock (Edition P 1)《航空航天系列 钢和耐热合金锻件的技术规范 第0.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1