FORD FLTM BJ 110-3-2001 MODIFIED OXIDATION WATER TOLERANCE TEST (Replaces FLTM BJ 010-03 FLTM EU-BJ 010-03).pdf

上传人:dealItalian200 文档编号:747114 上传时间:2019-01-14 格式:PDF 页数:6 大小:101.85KB
下载 相关 举报
FORD FLTM BJ 110-3-2001 MODIFIED OXIDATION WATER TOLERANCE TEST (Replaces FLTM BJ 010-03 FLTM EU-BJ 010-03).pdf_第1页
第1页 / 共6页
FORD FLTM BJ 110-3-2001 MODIFIED OXIDATION WATER TOLERANCE TEST (Replaces FLTM BJ 010-03 FLTM EU-BJ 010-03).pdf_第2页
第2页 / 共6页
FORD FLTM BJ 110-3-2001 MODIFIED OXIDATION WATER TOLERANCE TEST (Replaces FLTM BJ 010-03 FLTM EU-BJ 010-03).pdf_第3页
第3页 / 共6页
FORD FLTM BJ 110-3-2001 MODIFIED OXIDATION WATER TOLERANCE TEST (Replaces FLTM BJ 010-03 FLTM EU-BJ 010-03).pdf_第4页
第4页 / 共6页
FORD FLTM BJ 110-3-2001 MODIFIED OXIDATION WATER TOLERANCE TEST (Replaces FLTM BJ 010-03 FLTM EU-BJ 010-03).pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、 FORD LABORATORY TEST METHOD BJ 110-03 Date Action Revisions 2001 06 11 Revised Added Fig 1 3 low flash point. Petroleum Ether Reagent grade; low flash point. Distilled Water 10 ppm max dissolved solids (ASTM D 1888). Sand Paper 320 grit. Conditioning and Test Conditions All test values indicated he

2、rein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Set temperature regulator in test well to control the test lubricant

3、at 99 +/- 2 C. 2. Polish one SAE 1020 steel strip with sand paper for each lubricant to be tested (see figure 3). 3. Polish one standard Timken cup with sand paper for each lubricant to be tested and weigh. 4. Clean 500 mL beaker and weigh and add 200 mL of lubricant to be tested and weigh. 5. Add 2

4、.0 % distilled water by weight to test lubricant. 6. Hang SAE 1020 strip on each beaker flange ring (see figure 1). 7. Place one Timken cup in the bottom of each test beaker. 8. Place the beaker containing the test oil and water into the well or wells of the oxidation test stand. Insert the stirring

5、 rod through the opening of the stainless steel condenser cover and set condenser on beaker ring flange, with steel strip. 9. Adjust water flow through the condenser cover to maintain a temperature below 38 C. FORD LABORATORY TEST METHOD BJ 110-03 Page 3 of 6 Copyright 2001, Ford Global Technologies

6、, Inc. 10. Set automatic timer for 24 h after 99 +/- 2 C test temperature is attained and start stirring motor. 11. At the completion of 24 h of test, the steel strip and Timken cups are removed from each beaker. The test specimens are washed in petroleum ether and acetone and rated for stain and co

7、rrosion as follows: 9. No rust or stain 8. Slight stain 7. Slight stain and slight rust (does not pass) 6. Stain medium 5. Medium rust and stain 4. Complete black stain 2. Complete stain 12. The following data is reported at the conclusion of the test: (a) Oil identification (b) Test temperature (c)

8、 Test hours (d) Type of test specimen (e) Steel strip and cup rating (f) Condition of cup and strip Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities. FORD LABO

9、RATORY TEST METHOD BJ 110-03 Page 4 of 6 Copyright 2001, Ford Global Technologies, Inc. MODIFIED OXIDATION WATER TOLERANCE TEST Figure 1, Beaker Oxidation Test Set Up FORD LABORATORY TEST METHOD BJ 110-03 Page 5 of 6 Copyright 2001, Ford Global Technologies, Inc. MODIFIED OXIDATION WATER TOLERANCE TEST Figure 2, Beaker Cover FORD LABORATORY TEST METHOD BJ 110-03 Page 6 of 6 Copyright 2001, Ford Global Technologies, Inc. MODIFIED OXIDATION WATER TOLERANCE TEST Figure 3, Test Strip

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1