GSA A-A-2145-1983 LAMP INCANDESCENT (SEALED BEAM TRADE NO 6052)《(密封式灯 贸易号 6052)白炽灯》.pdf

上传人:cleanass300 文档编号:782424 上传时间:2019-01-23 格式:PDF 页数:1 大小:49.20KB
下载 相关 举报
GSA A-A-2145-1983 LAMP INCANDESCENT (SEALED BEAM TRADE NO 6052)《(密封式灯 贸易号 6052)白炽灯》.pdf_第1页
第1页 / 共1页
亲,该文档总共1页,全部预览完了,如果喜欢就下载吧!
资源描述

1、ISoD has determined that no military activity has an official interest in this commercial item description. PREPARING ACTIVITY: A-A-2145 b2 9979974 O002022 3 /q 93-97 A-A-2145 August 6, 1983 COMMERCIAL ITEM DESCRIPTION LAMP, INCANDESCENT (SEALED BEAM, TRADE No. 6052) The General Services Administrat

2、ion has authorized the use of this commercial item description. This description covers a rectangular sealed beam headlight for a two-headlamp system, type 2B 1. Salient characteristics: Rectangular bulb - 142 mm x 200 mm Design volts - 12.8 volts for each filament Watts - 65 watts for high beam, an

3、d 55 for low beam Three (3) contact lugs Filament designation - C6/C6 Average rated lab life, at 14 volts, in hours - 150 for upper beam, and 320 for low beam Lower beam filament is shielded The rectangular headlamp shall be in accordance with the Society of Automotive Engineers (SAE) Standard The i

4、ssue of SAE Standard 31132 in effect on the date of solicitation shall be used to determine compliance 31132 - 142 mm x 200 mm Sealed Beam Head Lamp Unit. with these requirements. coating, small bubbles in the glass, cracked glass, peeled reflective coating, and open or shorted filaments, Workmanshi

5、p. The lamp shall not have bent contacts, slight or complete discoloration of the lens or reflective Regulatory requirements. The offeror/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent practical. Preservation, packaging, packing, labeli

6、np, and marking. The preservation, packaging, packing, labeling, or marking shall be as specified in the contract or order. NOTE: must appear in the solicitation. SAE Standard 31 132 is available from the Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096. When this commercial item description is used for procurement, the commercial item certification clause CIVIL AGENCY COORDINATING ACTIVITY: GSA - FSS GSA - FSS THIS DOCUMENT %ONTAINS PAGES. FSC 6240 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • EN 61219-1993 en Live Working - Earthing or Earthing and Short- Circuiting Equipment Using Lances as a Short- Circuiting Device - Lance Earthing《带电作业 接地或用矛状物作为短路装置的接地和短路设备 矛式接地》.pdf EN 61219-1993 en Live Working - Earthing or Earthing and Short- Circuiting Equipment Using Lances as a Short- Circuiting Device - Lance Earthing《带电作业 接地或用矛状物作为短路装置的接地和短路设备 矛式接地》.pdf
  • EN 61221-2004 en Petroleum products and lubricants C Triaryl phosphate ester turbine control fluids (category ISO-L-TCD) - Specifications《石油产品和润滑剂 三芳基磷酸酯涡轮机控制液(ISO-L-TCD类) 规范 IEC 6.pdf EN 61221-2004 en Petroleum products and lubricants C Triaryl phosphate ester turbine control fluids (category ISO-L-TCD) - Specifications《石油产品和润滑剂 三芳基磷酸酯涡轮机控制液(ISO-L-TCD类) 规范 IEC 6.pdf
  • EN 61223-2-4-1994 en Evaluation and Routine Testing in Medical Imaging Departments Part 2-4 Constancy Tests - Hard Copy Cameras《医疗成像部门评定和常规试验 第2-4部分 稳定性试验 硬拷贝照相机(IEC 1223-2-4-1994).pdf EN 61223-2-4-1994 en Evaluation and Routine Testing in Medical Imaging Departments Part 2-4 Constancy Tests - Hard Copy Cameras《医疗成像部门评定和常规试验 第2-4部分 稳定性试验 硬拷贝照相机(IEC 1223-2-4-1994).pdf
  • EN 61223-2-5-1994 en Evaluation and Routine Testing in Medical Imaging Departments Part Part 2-5 Constancy Test -Image Display Devices《医疗成像部门评定和常规试验 第2-5部分 稳定性试验 图像显示设备(IEC 1223-2-.pdf EN 61223-2-5-1994 en Evaluation and Routine Testing in Medical Imaging Departments Part Part 2-5 Constancy Test -Image Display Devices《医疗成像部门评定和常规试验 第2-5部分 稳定性试验 图像显示设备(IEC 1223-2-.pdf
  • EN 61223-2-6-2007 en Evaluation and routine testing in medical imaging departments - Part 2-6 Constancy tests - Imaging performance of computed tomography X-ray equipment《医疗成像部门评定和.pdf EN 61223-2-6-2007 en Evaluation and routine testing in medical imaging departments - Part 2-6 Constancy tests - Imaging performance of computed tomography X-ray equipment《医疗成像部门评定和.pdf
  • EN 61223-3-1-1999 en Evaluation and Routine Testing in Medical Imaging Departments - Part 3-1 Acceptance Tests - Imaging Performance of X-Ray Equipment for Radiographic and Radiosc.pdf EN 61223-3-1-1999 en Evaluation and Routine Testing in Medical Imaging Departments - Part 3-1 Acceptance Tests - Imaging Performance of X-Ray Equipment for Radiographic and Radiosc.pdf
  • EN 61223-3-2-2008 en Evaluation and routine testing in medical imaging departments - Part 3-2 Acceptance tests - Imaging performance of mammographic X-ray equipment《医疗成像部门评定和常规试验 第.pdf EN 61223-3-2-2008 en Evaluation and routine testing in medical imaging departments - Part 3-2 Acceptance tests - Imaging performance of mammographic X-ray equipment《医疗成像部门评定和常规试验 第.pdf
  • EN 61223-3-3-1996 en Evaluation and Routine Testing in Medical Imaging Departments Part 3-3 Acceptance Tests - Imaging Performance of X-Ray Equipment for Digital Subtraction Angiog.pdf EN 61223-3-3-1996 en Evaluation and Routine Testing in Medical Imaging Departments Part 3-3 Acceptance Tests - Imaging Performance of X-Ray Equipment for Digital Subtraction Angiog.pdf
  • EN 61223-3-4-2000 en Evaluation and Routine Testing in Medical Imaging Departments Part 3-4 Acceptance Tests Imaging Performance of Dental X-Ray Equipment《医疗成像部门评定和常规试验 第3-4部分 验收试验.pdf EN 61223-3-4-2000 en Evaluation and Routine Testing in Medical Imaging Departments Part 3-4 Acceptance Tests Imaging Performance of Dental X-Ray Equipment《医疗成像部门评定和常规试验 第3-4部分 验收试验.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > GOST

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1