资源描述

1、*USACE / NAVFAC / AFCESA / NASA UFGS-008 36 19 (April 2006)-Preparing Activity: NAVFAC Replacing without change UFGS-08370 (August 2001)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated 1 April 2006Latest change indicated by CHG tags*SECTION TABLE OF CONTENTSDIVISION

2、 08 - OPENINGSSECTION 008 36 19VERTICAL LIFT DOORS04/06PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 MATERIALS2.1.1 Steel Sheet2.1.2 Steel Shapes2.1.3 Aluminum Extrusions2.1.4 Aluminum Sheets and Strips2.1.5 Glass2.2 DOORS2.3 MANUAL OPERATORS2.4 ELEC

3、TRIC OPERATORS2.4.1 Motors2.4.2 Controls2.4.3 Safety Device2.4.4 Control Transformers2.4.5 Electrical Components2.4.6 Hazardous Locations2.5 WEATHER SEALS AND SAFETY DEVICE2.6 FINISHES2.6.1 Galvanized and Shop Primed2.6.2 AluminumPART 3 EXECUTION3.1 FABRICATION3.1.1 Door Sections3.1.1.1 Insulated Se

4、ctions3.1.1.2 Aluminum SectionsSECTION 08 36 19 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.1.2 Guides and Jamb Plates3.1.3 Hardware3.1.4 Glazing3.2 INSTALLATION3.3 ELECTRICAL WORK3.4 TESTING- End of Section Table of Contents -SECTION 08

5、36 19 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-008 36 19 (April 2006)-Preparing Activity: NAVFAC Replacing without change UFGS-08370 (August 2001)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are

6、in agreement with UMRL dated 1 April 2006Latest change indicated by CHG tags*SECTION 008 36 19VERTICAL LIFT DOORS04/06*NOTE: This guide specification covers the requirements for vertical lift metal doors of the stacking type.Comments and suggestions on this guide specification are welcome and should

7、 be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).Use of electronic communication is e

8、ncouraged.Brackets are used in the text to indicate designer choices or locations where text must be supplied by the designer.*NOTE: On the drawings, show:1. Location and size of door openings.2. Type and details of door frames.3. Design wind loads required for the building.4. Wire and conduit from

9、power source to operators and controls for electrically-operated doors.5. Electrical power characteristics and location of motors and control station.6. Counterweight tower location relative to door.*SECTION 08 36 19 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without

10、license from IHS-,-,-PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use

11、the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automaticall

12、y be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.A

13、MERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)AISC 335 (1989) Structural Steel Buildings Allowable Stress Design and Plastic DesignASTM INTERNATIONAL (ASTM)ASTM A 123/A 123M (2002) Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM A 36/A 36M (2005) Carbon Structural SteelASTM A 653/A

14、 653M (2004a) Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM B 209 (2004) Aluminum and Aluminum-Alloy Sheet and PlateASTM B 209M (2004) Aluminum and Aluminum-Alloy Sheet and Plate (Metric)ASTM B 221 (2005) Aluminum and Aluminum-Alloy Extrude

15、d Bars, Rods, Wire, Profiles, and TubesASTM B 221M (2005) Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)SECTION 08 36 19 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NATIONAL ASSOCIATION OF ARCHITECTURAL

16、METAL MANUFACTURERS (NAAMM)NAAMM MFM (1988) Metal Finishes ManualNATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)NEMA ICS 1 (2000; R 2005) Industrial Control and Systems: General RequirementsNEMA ICS 2 (1996; R 2004) Standard for Industrial Control and Systems: Controllers, Contractors, and Over

17、load Relays Rated Not More than 2000 Volts AC or 750 Volts DC: Part 8 - Disconnect Devices for Use in Industrial Control EquipmentNEMA ICS 6 (1993; R 2001) Industrial Control and Systems: EnclosuresNEMA MG 1 (2003; R 2004) Motors and GeneratorsNEMA ST 20 (1992; R 1997) Dry-Type Transformers for Gene

18、ral ApplicationsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 70 (2005) National Electrical Code1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittal

19、s should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed throug

20、h the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation

21、 to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Projec

22、t Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.SECTION 08 36 19 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Choose the first bracketed item for Navy, Air Force and NASA projects, or choose th

23、e second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office tha

24、t will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsDoors; G; G, _Show types, sizes, locations, metal gages, hardware provisions, installation details, and other details of construction. For elec

25、trically operated doors, include supporting brackets for motors, location, type, and ratings of motors, and safety devices.SD-03 Product DataDoors; G; G, _ Motors; G; G, _ Controls; G; G, _ For electrically operated doors, submit manufacturers wiring diagrams for motors and controls.SD-08 Manufactur

26、ers InstructionsDoorsSD-10 Operation and Maintenance DataDoors, Data Package 2; ; G; G, _Submit in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA. Include wiring diagrams.1.3 DELIVERY, STORAGE, AND HANDLINGProtect doors and accessories from damage during delivery, storage, and handl

27、ing. Clearly mark manufacturers brand name. Store doors in dry locations with adequate ventilation, free from dust and water. Storage shall permit easy access for inspection and handling. Remove damaged items that cannot be restored to like-new condition and provide new items.PART 2 PRODUCTS2.1 MATE

28、RIALS2.1.1 Steel SheetASTM A 653/A 653M.SECTION 08 36 19 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1.2 Steel ShapesASTM A 36/A 36M.2.1.3 Aluminum ExtrusionsASTM B 221MASTM B 221, Alloy 6063-T5.2.1.4 Aluminum Sheets and StripsASTM B 209M

29、ASTM B 209, alloy and temper best suited for the purpose.2.1.5 GlassFully tempered, clear float glass, 3 _ mm 1/8 _ inch thick.2.2 DOORS*NOTE: The normal design wind load for vertical lift metal doors is one kPa 20 psf. If conditions require greater design loads, use appropriate loads.*Doors shall c

30、onsist of multiple sections set one behind the other. Arrange door operation and travel so that sections arrive simultaneously at the full open position. Sections shall stack vertically in a compact group above the head of the opening. Provide doors with counterweights. Doors, components, and method

31、s of installation shall be designed in accordance with AISC 335. Minimum design wind load shall be one kPa 20 psf as indicated for the building _ kPa psf. Maximum wind load deflection of the door shall not exceed the door height in mm inches divided by 120 and the door width in mm inches divided by

32、120. Doors shall be operable during design wind load.2.3 MANUAL OPERATORSProvide a galvanized, endless chain operating over a sprocket. Extend chain to within 900 mm 3 feet of the floor and mount on inside of building. Obtain reduction by use of roller chain and sprocket drive or gearing. Provide ch

33、ain cleat and pin for securing operator chain. Hoist shall allow for future installation of electric operators. The force required to operate the door shall not exceed 15.75 kilograms 35 pounds.2.4 ELECTRIC OPERATORS*NOTE: Specify three-phase motors wherever three-phase electrical service is or will

34、 be available. Locate control stations so operator will have complete visibility of the door at all times, within building at least 1500 mm 5 feet above floor line; one station should be placed about 600 mm 2 feet from jamb, guide, or track.*Provide operators of the type recommended by the door manu

35、facturer. Operators shall include electric motor, machine-cut reduction gears, steel chain and sprockets, magnetic brake, brackets, pushbutton controls, limit SECTION 08 36 19 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-switches, magnetic r

36、eversing contactor, a manual operator as specified above for emergency use, and other accessories necessary for operation. The electric operator shall be designed so that the motor may be removed without disturbing the limit switch timing and without affecting the manual operator. The manual operato

37、r shall be clutch controlled so that it may be engaged and disengaged from the floor; operation shall not affect limit switch timing. Provide an electrical or mechanical device that disconnects the motor from the operating mechanism when the manual operator is engaged.2.4.1 MotorsNEMA MG 1, high-sta

38、rting torque, reversible type with sufficient horsepower and torque output to move the door in either direction from any position. Motor shall produce a door travel speed of not less than 200 mm two-thirds foot or more than 300 mm one foot per second without exceeding the rated capacity. Motors shal

39、l operate on current of the characteristics indicated at not more than 377 rad/s 3600 rpm. Single-phase motors shall not have commutation or more than one starting contact. Motor enclosures shall be drip-proof type or NEMA totally enclosed non-ventilated (TENV) type. Install motors in approved locat

40、ions.2.4.2 ControlsEach door motor shall have an enclosed, across-the-line type, magnetic reversing contactor, thermal overload and undervoltage protection, solenoid-operated brake, limit switches, and control switches. Locate control switches at least 1500 mm 5 feet above the floor so the operator

41、will have complete visibility of the door at all times. Control equipment shall conform to NEMA ICS 1 and NEMA ICS 2. Control enclosures shall be NEMA ICS 6, Type 12 or Type 4, except that contactor enclosures may be Type 1. Each control switch station shall be of the three-button type; buttons shal

42、l be marked “OPEN,“ “CLOSE,“ and “STOP.“ The “OPEN“ and “STOP“ buttons shall require only momentary pressure to operate. The “CLOSE“ button shall require constant pressure to maintain the closing motion of the door. If the door is in motion and the “STOP“ button is pressed or the “CLOSE“ button rele

43、ased, the door shall stop instantly and remain in the stop position; from the stop position, the door may be operated in either direction by the “OPEN“ or “CLOSE“ buttons. Pushbuttons shall be full-guarded to prevent accidental operation. Provide limit switches to automatically stop doors at the ful

44、ly open and closed positions. Limit switch positions shall be readily adjustable.2.4.3 Safety DeviceProvide a safety device on the bottom edge of electrically operated doors. The device shall immediately stop and reverse the door in its closing travel upon contact with an obstruction in the door opening or upon failure of the device or any component of the control system and cause the door to return to the full open position. The door-closing circuit shall be automatically locked out and the