Active Insulin Infusion Control of the Blood Glucose Derivative.ppt

上传人:syndromehi216 文档编号:378009 上传时间:2018-10-09 格式:PPT 页数:18 大小:642KB
下载 相关 举报
Active Insulin Infusion Control of the Blood Glucose Derivative.ppt_第1页
第1页 / 共18页
Active Insulin Infusion Control of the Blood Glucose Derivative.ppt_第2页
第2页 / 共18页
Active Insulin Infusion Control of the Blood Glucose Derivative.ppt_第3页
第3页 / 共18页
Active Insulin Infusion Control of the Blood Glucose Derivative.ppt_第4页
第4页 / 共18页
Active Insulin Infusion Control of the Blood Glucose Derivative.ppt_第5页
第5页 / 共18页
亲,该文档总共18页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Active Insulin Infusion Control of the Blood Glucose Derivative,J G Chase, Z-H Lam, J-Y Lee and K-S HwangUniversity of Canterbury Dept of Mechanical Engineering Christchurch New ZealandICARCV 2002, Singapore,Silicon + Biology?,Many biological and/or medical processes are effectively feedback control

2、 systems or can have their function replaced by feedback systemsNew technology creating new possibilities: “BioMEMS” such as “wet sensors” and “gene chips”, are opening the path to real time physiological monitoring/sensing and actuation. Wireless technology (LAN and PAN) for communication between a

3、ctive elements and/or monitoring technology (increased information flow). Advanced embedded computers (DSPs) and real time operating systems (RTOSs) can now handle extensive calculations and operations required.Converging technologies enables the ability to monitor, control and/or replace dysfunctio

4、nal physiological behaviour(s).,Can the increased information from real-time sensing coupled with feedback control outperform the foreknowledge and intuition of an experienced diabetic?,3 Elements of Control Systems,Sensing Real-time sensing from GlucoWatch or similar technology at BW = 20 minutes o

5、r greaterComputation Modern embedded DSPs are far more than adequateActuation Insulin pumpAll are existing and near-term technologiesMust account for limitations of existing tech and determine the limits where practicality and feasibility occur together.,Diabetes,Current Treatment = Manual Monitorin

6、g + Injection = Error Prone,Diabetes is reaching epidemic proportions, treatment is dependent on unreliable individuals and has not changed significantly in 30+ years,GOALS: Automate the “5:95” (1 day every 3 weeks is “bad”) Account for variations in patient response, insulin employed, sensor bandwi

7、dth and actuator dynamics/limits.,System Model,System model is constructed in MATLAB/Simulink. Three parts: one part for each equation in model and controller. Controller: input - G and dG/dt (GlucoWatch) and output u(t) (Insulin Pump),Controllers,Relative proportional controller (RPC).,PD controlle

8、r controls slopes of incresing/decreasing blood sugar level rather than actual glucose concentration,Two controllers, one proportional based and the other derivative weighted where Kp Kd create two different approaches to controlShape control or Magnitude control,Why “Heavy Derivative” Control?,Deri

9、vative control - negative slope prevents further insulin injection when the glucose level is dropping and faster reaction to positive surge.,Control of Glucose Tolerance Test,As sampling rate increases, the more effective the controllers become. Optimal control: G is very nearly flat as desired,RPC

10、BW = 20 min,Insulin Infusion Rates for GTT,PD controller minics what a diabetic would usally do, a routine optimised over 70 years of clinical treatment. Insulin rates are sharper and nearer injections as sensor BW drops.,RPC sensor BW = 20 min,A More Difficult Test,1000 calories in 4 hours over fiv

11、e “meal” inputs of glucose which is rapidly absorbedInputs vary in magnitude from 50 400 caloriesInputs occur in two groups of rapid succession at t = 0, 10, 30 minutes and at t = 210 and 300 minutes The last meal is 40 calories from 980 1020 calories so the full absorption of about 1000 calories oc

12、curs by 4 hours quite easily.Controller has no knowledge of glucose input except in optimal case Input knowledge is not currently practicable in any way for this system in general,The goal is to “hammer” the system and see if it breaks!,Control of Glucose Inputs,Glucose excursions shrink with sensor

13、 BWOptimal control very nearly flat as desiredSimple PD control emphasizes derivative over proportional inputs by 100,Normal and Diabetic Glucose Response,Response of a normal subject to Glucose Input (orange) PD controller developed is slightly better than normal subject by 7-25% on peak value and

14、1+ hour in return to basal glucose level,Insulin Infusion Rates for Glucose Inputs,u(t)=Uo(1+Kp(G/Gb),Relative Proportional Control Comparison,Relative proportional control more robust to Hypoglycemic behaviour,Danger -1.5,Death -3,PD Controller against Sensor Lag,GlucoWatch (glucose sensor) has 20

15、minute sensor lagPD Controller ROBUST against 20 minute sensor lagThe peak is slightly increased, but less hypoglycemic response,(RPC),PD Controller against Sensor Failure,Sampling bandwidth = 20 minutesPD controller ROBUST against 20 minute failure Hypoglycemia induced for 60 minute failure,Summary

16、 & Conclusions,Bergman equations found to very suitable for control systems approachFeasibility of automated insulin infusion is shown in simulationBasic tradeoffs between sensor BW and control efficacy delineatedDerivative control or “control of slopes” seen to be the most effective form of feedbac

17、k so far versus proporational dominated or relative proportional.Insulin inputs with derivative control trending towards matching those of “optimized” insulin injection regimes followed by diabetics.,Ongoing Future Work = First Known Trials,GlucoCard error = 7%,Kidney Failure Dialysis Machine67 year old FemaleHigh fluid levels3rd day in ICUHyper-insulinemic and Hyper-glycemic,

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 教学课件 > 大学教育

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1