ASTM D483-2004(2009)e1 Standard Test Method for Unsulfonated Residue of Petroleum Plant Spray Oils《石油制植物喷洒油不磺化残渣的标准试验方法》.pdf

上传人:outsidejudge265 文档编号:511787 上传时间:2018-12-01 格式:PDF 页数:5 大小:130.76KB
下载 相关 举报
ASTM D483-2004(2009)e1 Standard Test Method for Unsulfonated Residue of Petroleum Plant Spray Oils《石油制植物喷洒油不磺化残渣的标准试验方法》.pdf_第1页
第1页 / 共5页
ASTM D483-2004(2009)e1 Standard Test Method for Unsulfonated Residue of Petroleum Plant Spray Oils《石油制植物喷洒油不磺化残渣的标准试验方法》.pdf_第2页
第2页 / 共5页
ASTM D483-2004(2009)e1 Standard Test Method for Unsulfonated Residue of Petroleum Plant Spray Oils《石油制植物喷洒油不磺化残渣的标准试验方法》.pdf_第3页
第3页 / 共5页
ASTM D483-2004(2009)e1 Standard Test Method for Unsulfonated Residue of Petroleum Plant Spray Oils《石油制植物喷洒油不磺化残渣的标准试验方法》.pdf_第4页
第4页 / 共5页
ASTM D483-2004(2009)e1 Standard Test Method for Unsulfonated Residue of Petroleum Plant Spray Oils《石油制植物喷洒油不磺化残渣的标准试验方法》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D 483 04 (Reapproved 2009)1Standard Test Method forUnsulfonated Residue of Petroleum Plant Spray Oils1This standard is issued under the fixed designation D 483; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year

2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEDeleted informational inch-pound units to make solely SI standard editorially in July 2009.1. Scope1.1 This test method co

3、vers the determination of unsul-fonated residue in plant spray oils of petroleum origin andapplies only to the petroleum oil content. It provides a measureof the degree of refinement of plant spray oils by determiningthe extent to which the oil is attacked by 98.61 % sulfuric acidunder closely stand

4、ardized conditions. Since the relationshipbetween unsulfonated residue and the actual composition of theoil is not known, this test method should be applied only formeasuring the degree of refinement and not for the determina-tion of aromatics or olefins, or both.1.2 The values stated in SI units ar

5、e to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices

6、 and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterD 1250 Guide for Use of the Petroleum MeasurementTablesD 1298 Test Method for Density, Relative Density (SpecificGravity), or API Gravity of Crude

7、 Petroleum and LiquidPetroleum Products by Hydrometer MethodD 4052 Test Method for Density and Relative Density ofLiquids by Digital Density MeterD 4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD 4177 Practice for Automatic Sampling of Petroleum andPetroleum Products3. Terminol

8、ogy3.1 Definitions:3.1.1 unsulfonated residue, nin oils, that portion of an oilremaining unsulfonated after treatment with concentrated sul-furic acid.4. Summary of Test Method4.1 A measured volume of sample is shaken with 98.61 %sulfuric acid at 100C in a Babcock bottle, shaking mechani-cally for 1

9、0 s at 10-min intervals. The volume not absorbed bythe acid is a measure of the unsulfonated residue in the sample.5. Significance and Use5.1 This test method is useful for distinguishing betweenoils that are adaptable to various types of spraying application,with a higher unsulfonated oil being req

10、uired for leaf sprayingas compared to dormant vegetation application.6. Apparatus6.1 Sulfonation FlaskThe flask is shown in Fig. A1.1 anddescribed in Annex A1.6.2 Meniscus Viewing Lens, focusing type, consisting ofeyepiece and objective to facilitate reading the meniscus witha minimum of parallax, i

11、s recommended.6.3 Water BathsTwo water baths maintained at 25 60.5C and 99.5 to 100C, and conforming to the requirementsprescribed in Annex A1.6.4 Shaking MachineThe exact design described in theappendix is required for uniform control of shaking andprecision results. Hand shaking is permissible if

12、technique isdeveloped to correlate results by machine shaking.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.06 on Analysis of Lubricants.Current edition approved April 15, 2009. Published July

13、 2009. Originallyapproved in 1961. Last previous edition approved in 2004 as D 48304.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary

14、page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.5 CentrifugeA centrifuge as described in Annex A1 isrecommended.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless othe

15、rwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high pu

16、rity to permit its use without lessening theaccuracy of the determination.7.1.1 Commercially prepared solutions may be used whenthey meet or exceed the specifications set in 7.1.7.2 Fuming Sulfuric Acid (approximately 15 % free SO3).(WarningSee 7.3 and 7.4.)7.3 Sulfuric Acid (98.61 %)Prepare by blen

17、ding reagent-grade fuming and concentrated sulfuric acids to a concentrationof 98.61 6 0.1 % H2SO4as determined by titration.(WarningCorrosive. Health hazard. Oxidizer.) (WarningWhile preparing the reagent, protect the face with a safetymask and place the flask in a tray.)7.4 Sulfuric Acid (sp gr 1.

18、84, approximately 95 %)Concentrated sulfuric acid (H2SO4). (WarningCorrosive.Health hazard. Oxidizer.).8. Reference Spray Oil48.1 Test results for unsulfonated residue are highly depen-dent upon rate of shaking. A reference spray oil has beencalibrated for unsulfonated residue by a group of cooperat

19、inglaboratories using both machine and hand shaking. Instructionsare given in Section 8 for using this reference oil as a guide toensure that the rate of shaking is correct.9. Calibration9.1 Machine Shaking RateA rate of 425 cycles/min wasused in the cooperative work to establish the unsulfonatedres

20、idue of the reference spray oil. There are small variations inseverity of shaking between individual machines, even whenthey are newly built and of the same make; and thesedifferences can increase with use. Consequently, each labora-tory shall run occasional tests on the reference spray oil. If anun

21、sulfonated residue is found which differs by more than60.4 % from the established value, the rate of shaking shall beadjusted accordingly. A faster rate tends to give a lowerunsulfonated residue, and vice versa.9.2 Hand Shaking RateEach operator shall standardizehis technique of shaking so as to obt

22、ain the established value(within 6 0.4 %) on the reference spray oil. A rate of 300cycles/min was used in the manual shaking tests in thecooperative program on the reference oil; however, an indi-vidual operators calibrated rate can differ appreciably from300 cycles/min.10. Sampling10.1 Obtain a sam

23、ple for this test method using PracticesD 4057 or D 4177.11. Procedure11.1 Adjust the temperature of the boiling water bath to 99.5to 100C and keep it in this temperature range throughout thetest. Adjust the shaker rate and check it before and after eachtest to make sure that the rate does not devia

24、te more than 610cycles/min from the rate established by calibration.(WarningWhen hand shaking, protect the face with a safetymask and point the Babcock bottle away from other personnel.Protect hands by wearing suitable safety gloves.)NOTE 1If hand shaking is used, shake the sulfonation flask bygrasp

25、ing the neck between the thumb and index finger and swinging theflask through an arc of approximately 20 so that the bottom of the flaskpasses through a distance of 64 to 89 mm. Shake at the rate established bycalibration within a tolerance of 610 cycles/min.11.2 Using Test Methods D 1298 or D 4052,

26、 determine thedensity at 25C in grams per millilitre by means of dataobtained from Vol VIII and Vol XI/XII of the PetroleumMeasurement Tables. (See Guide D 1250.)11.3 Weigh into a clean, dry sulfonation flask the equivalentof 4.9 to 5.1 mL of the sample at 25C, weighed to the nearest0.005 g, adding

27、the oil to the flask by pipet, and taking care todeposit as little oil as possible on the neck of the flask. Fromthe weight of the sample, calculate its volume at 25C.11.4 Slowly introduce 20 6 0.5 mL of H2SO4(98.61 %)into the flask in such a way that oil adhering to the neck of theflask will be was

28、hed down. Transfer the flask to the carrier, andsuspend the carrier in the boiling water bath, with the flaskimmersed to a point between the 0 and 10 marks, noting thetime when this is done. Close the cover of the bath, and directa gentle stream of air across the top of the flask to blow awayany ste

29、am arising from the opening.11.5 After the flask has been in the bath for 10 6 1 min,remove the carrier and install it, with minimum delay, on theshaker. While wearing a face shield, shake for 10 6 1sattherate established in the calibration with the reference spray oil.(WarningCertain samples of low

30、 unsulfonated residue canfoam excessively when shaken. Stop the shaker when the foamrises in the neck of the flask, and shake intermittently but at thespecified rate. Substitute the counter for the timer and shake atotal number of cycles equal to one-sixth of the numberrepresenting the established r

31、ate in cycles per minute, eventhough it requires more than 10 s for example, if the rate is 425cycles/min, shake 71 cycles.) After shaking, return the carrierto the bath as quickly as possible. Repeat the shaking at 10 61 min intervals for a total of six shaking periods, so that anhour has elapsed b

32、etween the time of placing the flask in thebath, and the removal for the final shaking.11.6 After the final shaking, cool to approximately roomtemperature, and add sufficient H2SO4(95 %) to raise the oil3Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washingto

33、n, DC. For Suggestions on the testing of reagents notlisted by the American Chemical Society, see Annual Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.4The reference

34、 spray oil may be obtained from R. E. Carroll, Inc., P.O. Box5806, 1570 North Olden Ave., Trenton, NJ 08638. If you are aware of alternativesuppliers, please provide this information to ASTM International Headquarters.Your comments will receive careful consideration at a meeting of the responsiblete

35、chnical committee,1which you may attend.D 483 04 (2009)12into the neck of the flask nearly to the top graduation. Place theflask in the centrifuge, balancing as necessary, and centrifugefor 10 min at a speed calculated by the equation given inA1.1.6, or taken from Table 1 to give a relative centrifu

36、galforce between 80 and 100 at the bottom of the flask. Transferthe flask to a water bath maintained at 25 6 0.5C for 10 6 1min, with the graduated neck immersed to the upper oil level.NOTE 2The use of rubber cushions in the centrifuge carrier tubes toavoid breakage is recommended.11.7 Transfer the

37、flask to the shelf in the 25C bath. Usinga suitable light source, and the aid of a viewing lens, record thereading on the graduated neck at the top and bottom of the oilcolumn, estimating to one fifth of the smallest division. Thebottom reading is generally sharp and straight across, andoffers no pr

38、oblem. In reading the top, hold a black strip (about10 by 50 mm) at the back of the neck, and about 5 mm belowthe top of the oil column, which makes the lowest meniscusappear as a black curve. Install the viewing lens at a right angleto the neck of the flask at the proper height, focus it, and readt

39、he lowest black meniscus. The upper and lower levels on theoil layer are represented by points A and B in Fig. 1. Point Adenotes the lowest portion of the boundary between the clearoil and the darkest part of the air-liquid interface, and point Brefers to the lowest portion of the interface between

40、the clearoil and sulfonation acid.11.8 Repeat the centrifuging and temperature equilibration(11.6 and 11.7), until constant readings have been obtained.12. Calculation and Report12.1 Correct the readings at the upper and lower oil surfacesin accordance with the calibration error.12.2 Calculate the u

41、nsulfonated residue as follows:Unsulfonated residue, volume % 5 A 2 B!/V 3 100 (1)where:A = corrected scale reading, at upper oil level, mL,B = corrected scale reading at lower oil level, mL, andV = volume of sample used, mL.12.3 Report all results to the nearest 0.2 %.13. Precision and Bias13.1 The

42、 precision of this test method as determined bystatistical examination of interlaboratory results is as follows:13.1.1 Repeatability The difference between two testresults, obtained by the same operator with the same apparatusunder constant operating conditions on identical test material,would in th

43、e long run, in the normal and correct operation ofthe test method, exceed the following values only in one casein twenty:Range of UnsulfonatedResidue, %Repeatability (MachineShaking)79 to 97 0.513.1.2 ReproducibilityThe difference between two singleand independent results obtained by different opera

44、tors work-ing in different laboratories on identical test material would, inthe long run, in the normal and correct operation of the testmethod, exceed the following values only in one case intwenty:Range of UnsulfonatedResidue, %Reproducibility (MachineShaking)79 to 97 2.013.2 The precision of this

45、 test method is not known to havebeen obtained in accordance with currently accepted guide-lines.13.3 BiasThere being no criteria for measuring bias inthese test product combinations, no statement of bias can bemade.14. Keywords14.1 petroleum plant spray oils; unsulfonated residueTABLE 1 Rotation Sp

46、eeds for Centrifuges of VariousDiameters of SwingDiameter of Swing,mmARpm at 80 rcf Rpm at 100 rcf508 530 590533 520 580559 510 570584 500 550609 490 540AMeasured in millimetres between bottoms of opposite flasks when in rotatingposition.FIG. 1 Method for Reading Volume of Unreacted OilD 483 04 (200

47、9)13ANNEX(Mandatory Information)A1. APPARATUSA1.1 ApparatusA1.1.1 Sulfonation Flask, as shown in Fig. A1.1. This is astandard Babcock test bottle known as “50 %, 9 g, 9 in., in0.5 %, cream test bottle.”A1.1.2 To calibrate the graduated neck of the flask: first, fillexactly to the zero mark with wate

48、r (see A1.1.2.2); thendetermine the true capacity to the 50 mark by adding waterfrom a standardized 10-mL buret. Calculate a volume calibra-tion factor.A1.1.2.1 The buret shall be subdivided to 0.01 or 0.02 mLand be provided with a tip delivering drops of approximately0.01 mL. Corrections to the nom

49、inal values of the buret shouldbe obtained in the laboratory and used in the calculation.A1.1.2.2 Water shall be reagent water conforming to Speci-fication D 1193, Type III.A1.1.3 Water Bath, maintained at 25 6 0.5C of sufficientdepth to permit immersion of the sulfonation flask to the topgraduation, and provided with a shelf at such a height that theflask, when placed on it, would be immersed to a point justbelow the bottom graduation.A1.1.4 Boiling-Water Bath, maintained at 99.5 to 100C,and of sufficient depth to permit immersion of the s

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1