CAN CSA-ISO IEC 7816-4A-2009 Identification cards - Integrated circuit cards - Part 4 Organization security and commands for interchange - AMENDMENT 1 Record activation and deactiv.pdf

上传人:boatfragile160 文档编号:590972 上传时间:2018-12-15 格式:PDF 页数:14 大小:2.57MB
下载 相关 举报
CAN CSA-ISO IEC 7816-4A-2009 Identification cards - Integrated circuit cards - Part 4 Organization security and commands for interchange - AMENDMENT 1 Record activation and deactiv.pdf_第1页
第1页 / 共14页
CAN CSA-ISO IEC 7816-4A-2009 Identification cards - Integrated circuit cards - Part 4 Organization security and commands for interchange - AMENDMENT 1 Record activation and deactiv.pdf_第2页
第2页 / 共14页
CAN CSA-ISO IEC 7816-4A-2009 Identification cards - Integrated circuit cards - Part 4 Organization security and commands for interchange - AMENDMENT 1 Record activation and deactiv.pdf_第3页
第3页 / 共14页
CAN CSA-ISO IEC 7816-4A-2009 Identification cards - Integrated circuit cards - Part 4 Organization security and commands for interchange - AMENDMENT 1 Record activation and deactiv.pdf_第4页
第4页 / 共14页
CAN CSA-ISO IEC 7816-4A-2009 Identification cards - Integrated circuit cards - Part 4 Organization security and commands for interchange - AMENDMENT 1 Record activation and deactiv.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Identification cards Integrated circuit cards Part 4: Organization, security and commands for interchange AMENDMENT 1: Record activation and deactivationAmendment 1:2009 (IDT) toNational Standard of CanadaCAN/CSA-ISO/IEC 7816-4-06(ISO/IEC 7816-4:2005, IDT)NOT FOR RESALE.PUBLICATION NON DESTINE LA RE

2、VENTE.CSA Standards Update ServiceAmendment 1:2009 toCAN/CSA-ISO/IEC 7816-4-06October 2009Title: Identification cards Integrated circuit cards Part 4: Organization, security and commands for interchange AMENDMENT 1: Record activation and deactivationPagination: 8 pages (iii preliminary and 5 text)To

3、 register for e-mail notification about any updates to this publicationgo to www.ShopCSA.caclick on E-mail Services under MY ACCOUNTclick on CSA Standards Update ServiceThe List ID that you will need to register for updates to this publication is 2418142.If you require assistance, please e-mail tech

4、supportcsa.ca or call 416-747-2233.Visit CSAs policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.Reference numberISO/IEC 7816-4:2005/Amd.1:2008(E)ISO/IEC 2008INTERNATIONAL STANDARD ISO/IEC7816-4Second edition2005-01-15AMENDMENT 12008-10-01Identification

5、cards Integrated circuit cards Part 4: Organization, security and commands for interchange AMENDMENT 1: Record activation and deactivation Cartes didentification Cartes circuit intgr Partie 4: Organisation, scurit et commandes pour les changes AMENDEMENT 1: Activation et dsactivation denregistrement

6、 ISO/IEC 7816-4:2005/Amd.1:2008(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the

7、editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can

8、 be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat

9、 at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO/IEC 2008 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing

10、 from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org ii ISO/IEC 2008 All rights reservedAmendment 1:2009 toCAN/CSA-ISO/IEC

11、 7816-4-06ISO/IEC 7816-4:2005/Amd.1:2008(E) ISO/IEC 2008 All rights reserved iiiForeword ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission) form the specialized system for worldwide standardization. National bodies that are members of ISO

12、 or IEC participate in the development of International Standards through technical committees established by the respective organization to deal with particular fields of technical activity. ISO and IEC technical committees collaborate in fields of mutual interest. Other international organizations

13、, governmental and non-governmental, in liaison with ISO and IEC, also take part in the work. In the field of information technology, ISO and IEC have established a joint technical committee, ISO/IEC JTC 1. International Standards are drafted in accordance with the rules given in the ISO/IEC Directi

14、ves, Part 2. The main task of the joint technical committee is to prepare International Standards. Draft International Standards adopted by the joint technical committee are circulated to national bodies for voting. Publication as an International Standard requires approval by at least 75 % of the n

15、ational bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO and IEC shall not be held responsible for identifying any or all such patent rights. Amendment 1 to ISO/IEC 7816-4:2005 was prepared by Joint Techn

16、ical Committee ISO/IEC JTC 1, Information technology, Subcommittee SC 17, Cards and personal identification. It contains the specification of a record life cycle status as well as the ACTIVATE RECORD and DEACTIVATE RECORD commands. Furthermore, the “Profile indicator” as an additional data object fo

17、r the file control parameters is defined. Amendment 1:2009 toCAN/CSA-ISO/IEC 7816-4-06ISO/IEC 7816-4:2005/Amd.1:2008(E) ISO/IEC 2008 All rights reserved 1Identification cards Integrated circuit cards Part 4: Organization, security and commands for interchange AMENDMENT 1: Record activation and deact

18、ivation Page iv, Foreword Add the following part to the list of parts: Part 13: Commands for application management in a multi-application environment Page 12, Table 6 Add a line to the row with SW1=62 as follows: SW1 SW2 Meaning 62 (warning) 87 At least one of the referenced records is deactivated

19、Page 19, 5.3.2 Replace the second list item and its two bullets with the following: Record structure The EF is seen at the interface as a single continuous sequence of individually identifiable records accessible by commands for handling records (see 7.3). Record numbering method is an EF-dependent

20、feature. Three attributes are defined. The size of the records is either fixed, or variable. The organization of the records is either a sequence (linear structure) or a ring (cyclic structure). A record life cycle state distinguishing at least the following states: ACTIVATED and DEACTIVATED. The co

21、ding of a record life cycle state is out of scope for this part of ISO/IEC 7816. Within a certain EF, either all records have a record life cycle state or no record has a record life cycle state. The presence of record life cycle states is indicated in the FCP (see Table 12). Page 20, Table 12 Add t

22、he following row after row 8E: Tag Length Value Applies to 8F 1 Profile indicator, see Table Amd.1-1 EF supporting records, once Amendment 1:2009 toCAN/CSA-ISO/IEC 7816-4-06ISO/IEC 7816-4:2005/Amd.1:2008(E) 2 ISO/IEC 2008 All rights reservedPage 21 Add the following new subclause after 5.3.3.3: 5.3.

23、3.4 Profile Indicator The following rules apply for the use of tag 8F in the file control parameters of any EF supporting records: If a data object with tag 8F is a) present, then the value field contains a profile indicator according to Table Amd.1-1; b) absent, then all records in the EF are impli

24、citly in the unchangeable state ACTIVATED. Table Amd.1-1 Coding of profile indicator b8 b7 b6 b5 b4 b3 b2 b1 Meaning 0 x x x x x x x Coding of profile indicator defined by ISO/IEC JTC 1/SC 17 0 x Record life cycle state 0 0 All records in this file are in the unchangeable state ACTIVATED 0 1 Each re

25、cord in this EF has its own record life cycle state, changeable by the commands ACTIVATE RECORD, DEACTIVATE RECORD and ACTIVATE FILE 1 x x x x x x x Proprietary coding of profile indicator Any other value is reserved for future use by ISO/IEC JTC 1/SC 17. Page 24, Table 17 In the rightmost column, r

26、eplace “ACTIVATE FILE” with “ACTIVATE FILE, ACTIVATE RECORD”. In the rightmost column, replace “DEACTIVATE FILE” with “DEACTIVATE FILE, DEACTIVATE RECORD”. Page 42, 7.3.2 In the last line of the first paragraph, replace “search or erase” with “search, erase, activate or deactivate”. Page 42, 7.3.2 I

27、nsert the following new paragraph after the first paragraph: The records in an EF may support record life cycle states. If so, in general deactivated records are not accessible by the commands READ RECORD, WRITE RECORD, UPDATE RECORD, ERASE RECORD and APPEND RECORD. If such a command is used, the re

28、spective command returns with the status bytes 6287 (at least one of the referenced records is deactivated). Furthermore, deactivated records shall be ignored, when executing a SEARCH RECORD command. Further details and exceptions to the general rules stated above are given in the following subsecti

29、ons. Amendment 1:2009 toCAN/CSA-ISO/IEC 7816-4-06ISO/IEC 7816-4:2005/Amd.1:2008(E) ISO/IEC 2008 All rights reserved 3Page 43, 7.3.3 Insert the following new paragraph after the first paragraph: If any record referenced by P1 and P2 is in record life cycle state DEACTIVATED, the command terminates wi

30、th the status bytes 6287 and the response data field shall be empty. Page 44, 7.3.4 Insert the following new paragraph after the fourth paragraph: If the record referenced by P1 and P2 is in the record life cycle state DEACTIVATED, the command terminates with the status bytes 6287 without changing t

31、he record content. Page 45, 7.3.5 Insert the following new list item after the third list item: If the record referenced by P1 and P2 is in the record life cycle state DEACTIVATED, the command terminates with the status bytes 6287 without changing the record content. Page 45, 7.3.6 Add the following

32、 sentence to the end of paragraph three: If the record with the highest record number is in the record life cycle state DEACTIVATED the command terminates with the status bytes 6287 without changing any record content or record number. Page 45, 7.3.6 Add the following new paragraph after paragraph t

33、hree: If the records in the EF have record life cycle states, the life cycle state of the appended record shall be set to ACTIVATED unless otherwise specified. Page 46, 7.3.7 Add the following new paragraph after paragraph two: Records with a record life cycle state set to DEACTIVATED shall be ignor

34、ed during the search. Page 46, 7.3.8 Add the following new paragraph after the first paragraph: If any record referenced by P1 and P2 is in record life cycle state DEACTIVATED, the command terminates with the status bytes 6287 without changing any record content. Amendment 1:2009 toCAN/CSA-ISO/IEC 7

35、816-4-06ISO/IEC 7816-4:2005/Amd.1:2008(E) 4 ISO/IEC 2008 All rights reservedPage 47 Add the following new clauses after 7.3.8: 7.3.9 ACTIVATE RECORD command The ACTIVATE RECORD command sets the record referenced by P1 and P2 to the record life cycle state ACTIVATED. The command shall not affect the

36、record pointer. If the EF referenced by P2 does not support record life cycle states, the command shall be aborted with the status bytes 6981. If the addressed record is already activated, the command shall return the status bytes 9000. Table Amd.1-2 ACTIVATE RECORD command-response pair CLA INS P1

37、P2 As defined in 5.1.1 08 Record number See Table Amd.1-3 Lc field Absent Data field Absent Le field Absent Data field Absent SW1-SW2 See Tables 5 and 6 when relevant, e.g. 6981, 6982, 6986, 6A82, 6A83 Table Amd.1-3 P2 b8 b7 b6 b5 b4 b3 b2 b1 Meaning x x x x x Short EF identifier according to Table

38、47 1 x x Record number in P1 1 0 0 Activate Record P1 Any other value is reserved for future use by ISO/IEC JTC 1/SC 17. 7.3.10 DEACTIVATE RECORD command The DEACTIVATE RECORD command sets the record referenced by P1 and P2 to the record life cycle state DEACTIVATED. The command shall not affect the

39、 record pointer. If the EF referenced by P2 does not support record life cycle states, the command shall be aborted with the status bytes 6981. If the addressed record is already deactivated, the command shall return the status bytes 9000. For the activation of all records in the record life cycle s

40、tate DEACTIVATED, the ACTIVATE FILE command may be used. Independent from the modification of an optionally present file life cycle state (see ISO/IEC 7816-9) all records will be activated. For activating individual records the ACTIVATE RECORD command shall be used. Amendment 1:2009 toCAN/CSA-ISO/IE

41、C 7816-4-06ISO/IEC 7816-4:2005/Amd.1:2008(E) ISO/IEC 2008 All rights reserved 5Table Amd.1-4 DEACTIVATE RECORD command-response pair CLA INS P1 P2 As defined in 5.1.1 06 Record number See Table Amd.1-5 Lc field Absent Data field Absent Le field Absent Data field Absent SW1-SW2 See Tables 5 and 6 whe

42、n relevant, e.g. 6981, 6986, 6A82, 6A83 Table Amd.1-5 P2 b8 b7 b6 b5 b4 b3 b2 b1 Meaning x x x x x Short EF identifier according to Table 47 1 x x Record number in P1 1 0 0 Deactivate Record P1 Any other value is reserved for future use by ISO/IEC JTC 1/SC 17. Amendment 1:2009 toCAN/CSA-ISO/IEC 7816

43、-4-06ISO/IEC 7816-4:2005/Amd.1:2008(E) ICS 35.240.15 ISO/IEC 2008 All rights reserved Copyright NoticeThis Amendment to the International Standard contains information copyright protected by the International Organization for Standardization (ISO) and the International Electrotechnical Commission (I

44、EC). Except as permitted under the laws of Canada, no extract of this Amendment to the International Standard may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, electronic, photocopying, recording, or otherwise, without prior permission from the Standards

45、Council of Canada (SCC). Requests for permission to reproduce this Amendment to the International Standard or parts thereof should be addressed to Manager, Technical Document Centre Standards Council of Canada 270 Albert Street, Suite 200 Ottawa, Ontario K1P 6N7 The Canadian adoption of this Amendme

46、nt to the International Standard contains information copyright protected by the Canadian Standards Association. All rights reserved. No part of this adopted Amendment may be reproduced in any form whatsoever without the prior permission of the publisher. ISO/IEC material is reprinted with permissio

47、n. Requests for permission to reproduce this adopted Amendment or parts thereof should be addressed to Manager, Sales Canadian Standards Association 5060 Spectrum Way, Suite 100 Mississauga, Ontario L4W 5N6Copyright violators will be prosecuted to the full extent of the law.PRINTED IN CANADAIMPRIMEAU CANADA100%The Canadian Standards Association (CSA) prints its publications on Rolland Enviro100, which contains 100% recycled post-consumer fibre, is EcoLogo and Processed Chlorine Free certified, and was manufactured using biogas energy.

展开阅读全文
相关资源
猜你喜欢
  • BS 5791-2-1979 Glossary of terms for compressors pneumatic tools and machines - Compressors《压缩机、气动工具和气动机械术语 第2部分 压缩机》.pdf BS 5791-2-1979 Glossary of terms for compressors pneumatic tools and machines - Compressors《压缩机、气动工具和气动机械术语 第2部分 压缩机》.pdf
  • BS 5791-3-1990 Glossary of terms for compressors pneumatic tools and machines - Pneumatic tools and machines《压缩机、气动工具和机械术语 第3部分 气动工具与机械》.pdf BS 5791-3-1990 Glossary of terms for compressors pneumatic tools and machines - Pneumatic tools and machines《压缩机、气动工具和机械术语 第3部分 气动工具与机械》.pdf
  • BS 5793-6-1986 Industrial-process control valves - Specificaton for mounting details for attachment of positioners to control valve actuators《工业过程控制阀 定位器控制阀引动器附件安装详细规范》.pdf BS 5793-6-1986 Industrial-process control valves - Specificaton for mounting details for attachment of positioners to control valve actuators《工业过程控制阀 定位器控制阀引动器附件安装详细规范》.pdf
  • BS 5797-1986 Methods for measurement of gassing of insulation liquids under electrical stress and ionization《电应力和电离作用下绝缘液气泡测定方法》.pdf BS 5797-1986 Methods for measurement of gassing of insulation liquids under electrical stress and ionization《电应力和电离作用下绝缘液气泡测定方法》.pdf
  • BS 5803-2-1985 Thermal insulation for use in pitched roof spaces in dwellings - Specification for man-made mineral fibre thermal insulation in pelleted or granular form for applica.pdf BS 5803-2-1985 Thermal insulation for use in pitched roof spaces in dwellings - Specification for man-made mineral fibre thermal insulation in pelleted or granular form for applica.pdf
  • BS 5803-3-1985 Thermal insulation for use in pitched roof spaces in dwellings - Specification for cellulose fibre thermal insulation for application by blowing《坡屋顶空间隔热 第3部分 喷吹纤维素纤维.pdf BS 5803-3-1985 Thermal insulation for use in pitched roof spaces in dwellings - Specification for cellulose fibre thermal insulation for application by blowing《坡屋顶空间隔热 第3部分 喷吹纤维素纤维.pdf
  • BS 5803-4-1985 Thermal insulation for use in pitched roof spaces in dwellings - Methods for determining flammability and resistance to smouldering《坡屋顶空间隔热 第4部分 易燃性和耐燃性测定方法》.pdf BS 5803-4-1985 Thermal insulation for use in pitched roof spaces in dwellings - Methods for determining flammability and resistance to smouldering《坡屋顶空间隔热 第4部分 易燃性和耐燃性测定方法》.pdf
  • BS 5803-5-1985 Thermal insulation for use in pitched roof spaces in dwellings - Specification for installation of man-made mineral fibre and cellulose fibre insulation《坡屋顶空间隔热 第5部分.pdf BS 5803-5-1985 Thermal insulation for use in pitched roof spaces in dwellings - Specification for installation of man-made mineral fibre and cellulose fibre insulation《坡屋顶空间隔热 第5部分.pdf
  • BS 5808-1991 Specification for underlays for textile floor coverings《铺地织物用衬垫规范》.pdf BS 5808-1991 Specification for underlays for textile floor coverings《铺地织物用衬垫规范》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1