1、 MIL-DTL-49285/9A INCH-POUND15 May 2009 SUPERSEDING MIL-C-49285/9 19 October 1989 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, ELEVEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG Inactive for new design after 16 June 1997.This specification is approved for use by all Departments

2、and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-49285. FIGURE 1. Cable illustration. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro

3、m IHS-,-,-MIL-DTL-49285/9A Engineering information: See table I. Note: Not for aerospace use. TABLE I. Description, electrical. Electrical characteristics Requirements Nominal capacitance between conductors Nominal capacitance between the conductor and the shield with one conductor tied to the shiel

4、d Continuous working voltage Nominal capacitance between adjacent shields Continuous working voltage between adjacent shields Shield dc resistance 30 pF/ft (picofarads/foot) 55 pF/ft 300 V rms maximum between conductors 150 pF/ft 50 volts maximum 14 ohms/1,000 feet maximum TABLE II. Description, phy

5、sical. Components Construction details Number of pairs Conductor type and wire size Conductor stranding Conductor insulation Conductor insulation thickness Drain wire type and size Drain wire stranding Jacket material Jacket thickness Finished cable diameter Cable style (UL) Tensile strength (jacket

6、) Elongation (jacket) Overall cabling lay length Eleven individually shielded Stranded tinned copper 22 AWG 7 X 30 AWG Polypropylene 0.010 inch nominal thickness Stranded tinned copper 22 AWG 16 X 34 AWG Polyvinyl chloride 0.033 inch 0.510 inch maximum outside diameter 2493 2,000 pounds per square i

7、nch minimum 150 percent minimum 1.3 twists per foot 10 percent Cabled pair orientation. The position of the red and green pair shield shall determine the rotation direction for pair location (see figure 1). 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH

8、S-,-,-MIL-DTL-49285/9A TABLE III. Shield color code. Pair numbers Shield color Center core 1stpair 2ndpair 3rdpair Outer layer 4thpair 5thpair 6thpair 7thpair 8thpair 9thpair 10thpair 11thpair Red Green Blue 1 Red Green Blue 1 Blue 2 Blue 3 Blue 4 Blue 5 Blue 6 REQUIREMENTS: Design and construction.

9、 See tables I, II and III. Shield location and orientation. The polyester aluminum shield is to be located on the outer circumference of the pair, with the aluminum foil side outward. Insulation on the interior of the shield is to be complete with no aluminum available for contact. Drain wire locati

10、on. The drain wire is to be spirally located between the noise reducing tape and the aluminum foil shield, and is to be in continuous contact with the aluminum surface of the foil shield and the noise reducing tape throughout the cable. Cable temperature rating. The cable temperature rating shall be

11、 -20C to +80C. Flammability. The cable shall pass UL 2556 flame test requirements. Shield integrity test.* Frequency Response * 100 kHz 115 dB below reference 500 kHz 107 dB below reference 1 MHz 101 dB below reference 5 MHz 87 dB below reference 10 MHz 81 dB below reference 15 MHz 77 dB below refer

12、ence 20 MHz 73 dB below reference 25 MHz 69 dB below reference 30 MHz 65 dB below reference 100 MHz 45 dB below reference * Any two readings may deviate to a value of 0.9 times the stated limits. * All values are a minimum numerical value. Fixture resonance will occur between 40 and 70 MHz. 3Provide

13、d by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49285/9A 4Crosstalk test limits. All values are minimums. Frequency (kHz) Near end crosstalk (dB) Far end crosstalk (dB) 40 57 57 70 54 53 100 52 51 1,000 53 51 Insulation resistance between shields. 1

14、00 megohms/1,000 feet minimum. Durometer hardness. The cable jacket shall have a “Shore A” hardness of 82 5. Part or Identifying Number (PIN). The PIN shall be M49285/09. Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the

15、previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notat

16、ions and relationship to the last previous issue. Referenced documents. In addition to MIL-DTL-49285, this document references the following: UL 2556. CONCLUDING MATERIAL Custodians: Preparing activity: Army CR DLA-CC Navy SH Air Force 85 DLA - CC Review activities: Army MI (Project 6145-2009-014) A

17、ir Force 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change. You should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN V 17912-1999 Copper and copper alloys - Provisions and procedures for the allocation of material numbers and registration of materials (CR 12776 1997)《铜和铜合金 材料号码的分配和材料登记的规定和程序》.pdf DIN V 17912-1999 Copper and copper alloys - Provisions and procedures for the allocation of material numbers and registration of materials (CR 12776 1997)《铜和铜合金 材料号码的分配和材料登记的规定和程序》.pdf
  • DIN V 18004-2004 Use of building products in construction works - Test methods for aggregates according to DIN V 20000-103 and DIN V 20000-104《施工作业中建筑产品的使用 符合DIN V 20000-103和DIN V .pdf DIN V 18004-2004 Use of building products in construction works - Test methods for aggregates according to DIN V 20000-103 and DIN V 20000-104《施工作业中建筑产品的使用 符合DIN V 20000-103和DIN V .pdf
  • DIN V 18026-2006 Surface protection systems for concrete products according to DIN EN 1504-2 2005-01《符合DIN EN 1504-2-2005的混凝土产品用表面保护系统》.pdf DIN V 18026-2006 Surface protection systems for concrete products according to DIN EN 1504-2 2005-01《符合DIN EN 1504-2-2005的混凝土产品用表面保护系统》.pdf
  • DIN V 18028-2006 Injection products according to DIN EN 1504-5 2005-03 with special features《根据DIN EN 1504-5 2005-03有关特殊特征的注射产品》.pdf DIN V 18028-2006 Injection products according to DIN EN 1504-5 2005-03 with special features《根据DIN EN 1504-5 2005-03有关特殊特征的注射产品》.pdf
  • DIN V 18032-2-2001 Sport halls - Halls for gymnastics games and multi-purpose use - Part 2 Floors for sporting activities Requirements testing《运动大厅 体操、运动和多功能厅 第2部分 体育活动用地板 要求和试验》.pdf DIN V 18032-2-2001 Sport halls - Halls for gymnastics games and multi-purpose use - Part 2 Floors for sporting activities Requirements testing《运动大厅 体操、运动和多功能厅 第2部分 体育活动用地板 要求和试验》.pdf
  • DIN V 18073-2008 Roller shutters awnings rolling doors and other blinds and shutters in buildings - Terms and requirements《建筑用滚动式百叶窗、遮阳伞、滚轮式移动门和其它遮帘和百叶窗 术语和要求》.pdf DIN V 18073-2008 Roller shutters awnings rolling doors and other blinds and shutters in buildings - Terms and requirements《建筑用滚动式百叶窗、遮阳伞、滚轮式移动门和其它遮帘和百叶窗 术语和要求》.pdf
  • DIN V 18151-100-2005 Lightweight concrete hollow blocks - Part 100 Hollow blocks with specific properties《轻质混凝土空心砌块 第100部分 具有特殊性能的空心砌块》.pdf DIN V 18151-100-2005 Lightweight concrete hollow blocks - Part 100 Hollow blocks with specific properties《轻质混凝土空心砌块 第100部分 具有特殊性能的空心砌块》.pdf
  • DIN V 18152-100-2005 Lightweight concrete solid bricks and blocks - Part 100 Solied bricks and blocks with specific properties《轻质混凝土实心砖和砌块 第100部分 具有特殊性能的实心砖和砌块》.pdf DIN V 18152-100-2005 Lightweight concrete solid bricks and blocks - Part 100 Solied bricks and blocks with specific properties《轻质混凝土实心砖和砌块 第100部分 具有特殊性能的实心砖和砌块》.pdf
  • DIN V 18153-100-2005 Concrete masonry units (Normal-weight concrete) - Part 100 Masonry units with specific properties《混凝土砌块(标准重量混凝土) 第100部分 具有特殊性能的砌块》.pdf DIN V 18153-100-2005 Concrete masonry units (Normal-weight concrete) - Part 100 Masonry units with specific properties《混凝土砌块(标准重量混凝土) 第100部分 具有特殊性能的砌块》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1