1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Changes in accordance with NOR 5962-R149-92. 92-02-20 Alan BaroneB Paragraph 1.3; changed power dissipation from 6 watts to 7 watts. Table I; changed the max limit for the overload power dissipation test from 6 watts to 7 watts. Redrew entire doc
2、ument. -sld 01-04-09 Raymond Monnin C Update drawing. -gz 05-11-16 Raymond Monnin D Table II, add note to Group C end-point test parameters. Update boilerplate paragraphs. -gz 10-02-02 Charles F. Saffle THE ORIGINAL FIRST SHEET OF THIS DRAWING HAS BEEN REPLACED. REV SHEET REV SHEET REV STATUS REV D
3、D D D D D D D D D D D OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 PMIC N/A PREPARED BY Gary Zahn DEFENSE SUPPLY CENTER COLUMBUS STANDARD MICROCIRCUIT DRAWING CHECKED BY Robert M. Heber COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Wi
4、lliam K. Heckman MICROCIRCUIT, HYBRID, LINEAR, 15 VOLT, SINGLE CHANNEL, DC/DC CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 91-04-22 AMSC N/A REVISION LEVEL D SIZE A CAGE CODE 67268 5962-91625 SHEET 1 OF 12 DSCC FORM 2233 APR 97 5962-E181-10Provided by IHSNot for ResaleNo
5、 reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-91625 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defi
6、ned in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the fol
7、lowing example: 5962 - 91625 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shal
8、l meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 AHE2815S DC/DC converter, 20
9、 W, 15 V output 02 AHE2815S/CH-SLV DC/DC converter, 20 W, 15 V output 03 AHE2815S/CH-MSTR DC/DC converter, 20 W, 15 V output 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL
10、-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications
11、. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited
12、temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C, and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that
13、 class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufactu
14、rers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-91625 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LE
15、VEL D SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outlines. The case outlines are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 10 Dual-in-line Z See figure 1 10 Flange package 1.2.5 Lead finish. The lead finish shall be as sp
16、ecified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage . -0.5 V dc to +50 V dc Power dissipation (PD) . 7 W Lead temperature (soldering, 10 seconds) +300C Storage temperature -65C to +135C 1.4 Recommended operating conditions. Input voltage range . +17 V dc to +40 V dc Case operati
17、ng temperature range (TC). -55C to +125C Output power 2/ 20 W 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of th
18、ese documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Compo
19、nent Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Ro
20、bbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unle
21、ss a specific exemption has been obtained. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Derate output power linearly above case temperature +125C to 0 at +135C.Prov
22、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-91625 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 4 DSCC FORM 2234 APR 97 3. REQUIREMENTS 3.1 Item requirements. The individual
23、item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable de
24、vice class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not affect the form, fit, or function of
25、the device for the applicable device class. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38534 and herein. 3.2.1 Case outlines. The case outlines shall be in accordance with 1.2.4 herein and figure 1. 3.2.2 Term
26、inal connections. The terminal connections shall be as specified on figure 2. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full specified operating temperature range. 3.4
27、 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are defined in table I. 3.5 Marking of devices. Marking of devices shall be in accordance with MIL-PRF-38534. The device shall be marked with the PIN l
28、isted in 1.2 herein. In addition, the manufacturers vendor similar PIN may also be marked. 3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described herein shall maintain the electrical test data (variables format) from the initial quali
29、ty conformance inspection group A lot sample, for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be mad
30、e available to the preparing activity (DSCC-VA) upon request. 3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this drawing. The certificate of compliance (original copy) submitted to DSCC-VA shall affirm that the manufacturers pr
31、oduct meets the performance requirements of MIL-PRF-38534 and herein. 3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of microcircuits delivered to this drawing. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspec
32、tion procedures shall be in accordance with MIL-PRF-38534 or as modified in the device manufacturers Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. Provided by IHSNot for ResaleNo reproduction or networking permitted wit
33、hout license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-91625 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions -55C TC+125C VIN= 28 V dc 5%, CL= 0 unless otherwi
34、se specified Group A subgroups Device types Limits Unit Min Max Output voltage VOUTIOUT= 0 1 All 14.85 15.15 V 2,3 14.70 15.30 Output current 1/ IOUTVIN= 17, 28, and 40 V dc 1,2,3 All 1.333 A Output ripple voltage 2/ VRIPVIN= 17, 28, and 40 V dc, B.W. = dc to 2 MHz 1,2,3 All 60 mV p-p Output power 1
35、/ 3/ POUTVIN= 17, 28, and 40 V dc 1,2,3 All 20 W Line regulation VRLINEVIN= 17, 28, and 40 V dc, IOUT= 0, .677, and 1.333 A 1 All 35 mV 2,3 75 Load regulation VRLOADVIN= 17, 28, and 40 V dc, IOUT= 0, .677, and 1.333 A 1,2,3 All 150 mV Input current IINIOUT= 0, inhibit (pin 2) tied to input return (p
36、in 10) 1,2,3 All 18 mA IOUT= 0, inhibit (pin 2) = open 35 Input ripple current 2/ IRIPIOUT= 1.333 A, B.W. = dc to 2 MHz 1,2,3 All 50 mA p-p Efficiency EFF IOUT= 1.333 A, TC= +25C 1 All 80 % Isolation ISO Input to output or any pin to case (except pin 8) at 500 V dc, TC= +25C 1 All 100 M Capacitive l
37、oad 4/ 5/ CLNo effect on dc performance, TC= +25C 4 All 200 F Power dissipation, load fault PDOverload, TC= +25C 6/ 1 All 7 W Short circuit, TC= +25C 6 See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCU
38、IT DRAWING SIZE A 5962-91625 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 6 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - Continued. Test Symbol Conditions -55C TC+125C VIN= 28 V dc 5%, CL= 0 unless otherwise specified Group A subgroups De
39、vice types Limits Unit Min Max Switching frequency FSIOUT= 1.333 A 4,5,6 01 225 275 kHz 02 225 245 03 250 275 Output response to step transient load changes 7/ VOTLOAD50% load to/from 100% load 4,5,6 All -300 +300 mV pk No load to/from 50% 4 All -500 +500 5,6 -750 +750 Recovery time step transient l
40、oad changes 7/ 8/ TTLOAD50% load to/from 100% load 4,5,6 All 70 s No load to/from 50% load 1500 50% load to no load 5 ms Output response to transient step line changes 5/ 9/ VOTLINE Input step 17 to 40 V dc 4,5,6 All 500 mV pk Input step 40 to 17 V dc 4,5,6 All -1500 Recovery time transient step lin
41、e changes 5/ 8/ 9/ TTLINEInput step 17 to 40 V dc 4,5,6 All 800 s Input step 40 to 17 V dc 800 Turn on overshoot VtonOSIOUT= 0 A and 1.333 A 4,5,6 All 500 mV pk Turn-on delay TonDIOUT= 0 A and 1.333 A 10/ 4,5,6 All 10 ms Load fault recovery 5/ trLF4,5,6 All 10 ms See footnotes at top of next page. P
42、rovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-91625 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 7 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - C
43、ontinued. 1/ Parameter guaranteed by line and load regulation tests. 2/ Bandwidth guaranteed by design. Tested for 20 kHz to 2 MHz. 3/ For operation at 16 V dc input, derate output by 33 percent. 4/ Capacitive load may be any value from 0 to the maximum limit without affecting dc performance. A capa
44、citive load in excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing as a short circuit during turn on. 5/ Parameter shall be tested as part of design characterization and after design and or process changes.
45、 Therefore the parameter shall be guaranteed to the limits specified in table I. 6/ An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit protection and is the condition of maximum power dissipation. 7/ Load step transition ti
46、me between 2 and 10 microseconds. 8/ Recovery time is measured from the initiation of the transient to where VOUThas returned to within 1 percent of VOUTat 50 percent load. 9/ Input step transition time between 2 and 10 microseconds. 10/ Turn on delay time measurement is for either a step applicatio
47、n of power at input or the removal of a ground signal from the inhibit pin (pin 2) while power is applied to the input. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-91625 DEFENSE SUPPLY CENTER COLUMBUS COL
48、UMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 8 DSCC FORM 2234 APR 97 Case outline X. Symbol Millimeters Inches Min Max Min Max A 12.57 .495 b 0.89 1.14 .035 .045 D 53.85 2.120 e 10.03 10.28 .395 .405 E 28.45 1.120 E1 20.19 20.45 .795 .805 L 6.48 6.73 .255 .265 NOTES: 1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch- pound units of measurement. In case of problems involving con