EN 61300-2-50-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-50 Tests - Fibre optic connector proof test with s.pdf

上传人:twoload295 文档编号:720004 上传时间:2019-01-04 格式:PDF 页数:12 大小:291.54KB
下载 相关 举报
EN 61300-2-50-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-50 Tests - Fibre optic connector proof test with s.pdf_第1页
第1页 / 共12页
EN 61300-2-50-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-50 Tests - Fibre optic connector proof test with s.pdf_第2页
第2页 / 共12页
EN 61300-2-50-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-50 Tests - Fibre optic connector proof test with s.pdf_第3页
第3页 / 共12页
EN 61300-2-50-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-50 Tests - Fibre optic connector proof test with s.pdf_第4页
第4页 / 共12页
EN 61300-2-50-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-50 Tests - Fibre optic connector proof test with s.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 61300-2-50: 2007Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-50: Tests Fibre optic connector proof test with static load Singlemode and multimode The European Standard EN 61300-2-50:2007 has the status of a British Stan

2、dardICS 33.180.20 BS EN Incorporating corrigendum January 2015BS EN 61300-2-50:2007ISBN 978 0 580 89482 4Amendments/corrigenda issued since publicationDate Comments31 January 2015 Implementation of IEC corrigendum January 2015.This British Standard was published under the authority of the Standards

3、Policy and Strategy Committee on 31 August 2007 The British Standards Institution 2015. Published by BSI Standards Limited 2015National forewordThis British Standard is the UK implementation of EN 61300-2-50:2007. It is identical to IEC 61300-2-50:2007, incorporating corrigendum January 2015.The sta

4、rt and finish of text introduced or altered by corrigendum is indicated in the text by tags. Text altered by IEC corrigendum January 2015 is indicated in the text by .The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre op

5、tic interconnecting devices and passive components.A list of organizations represented on this subcommittee can be obtained on request to its secretary.The publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance

6、 with a British Standard cannot confer immunity from legal obligations.EUROPEAN STANDARD EN 61300-2-50NORME EUROPENNE EUROPISCHE NORMAugust 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische No

7、rmung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any formand byany means reserved worldwide for CENELEC members. Ref. No. EN 61300-2-50:2007 E ICS 33.180.20 English version Fibre optic interconnecting devices and passive components - Basic

8、 test and measurement procedures - Part 2-50: Tests - Fibre optic connector proof test with static load - Singlemode and multimode (IEC 61300-2-50:2007)Dispositifs dinterconnexion et composants passifs fibres optiques - Mthodes fondamentales dessais et de mesures - Partie 2-50: Essais - Essai de rsi

9、stance des connecteurs fibres optiques sous charge statique - Unimodal et multimodal (CEI 61300-2-50:2007) Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prf- und Messverfahren - Teil 2-50: Prfungen - Festigkeitsprfung fr Lichtwellenleiter-Steckverbinder - Einmoden und M

10、ehrmoden (IEC 61300-2-50:2007) This European Standard was approved by CENELEC on 2007-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving thisEuropean Standard the status of anational standard without any alteration. Up-to-da

11、te lists and bibliographical references concerning suchnational standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three officialversions (English, French, German). A version in any other language made by translation under t

12、he responsibility of aCENELEC member into its own language andnotified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, theCzechRepublic, Denmark, Estonia, Finland, France, Ger

13、many, Greece, Hungary, Iceland, Ireland, Italy,Latvia, Lithuania,Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain,Sweden, Switzerland and the United Kingdom. Foreword The text of document 86B/2509/FDIS, future edition 1 of IEC 61300-2-50, prepared by SC

14、 86B, Fibreoptic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-2-50 on 2007-07-01. The following dates were fixed: latest date by which the EN has to be implementedat national level b

15、y publication of an identical national standard or by endorsement (dop) 2008-04-01 latest date by which the national standards conflictingwith the EN have to be withdrawn (dow) 2010-07-01 Annex ZA has been added by CENELEC. _ NoticeThis document containsmaterial that is Copyright 2006, Telcordia Tec

16、hnologies, Inc. (“Telcordia“). All rights reserved. The reader is advised that this IEC document and Telcordia source(s) may differ, and the context and use of said material in this IEC document may differ from that of Telcordia. Telcordia makes no representationor warranty, express or implied, with

17、 respect to the sufficiency, accuracy, or utility of any information or opinion contained herein. Any use of or reliance upon said information or opinion is at the risk of the user. Telcordia shall not be liable for any damage or injury incurred by any person arising out of the sufficiency, accuracy

18、, or utility of any information or opinion contained herein. _ Endorsement notice The text of the International Standard IEC 61300-2-50:2007 was approved by CENELEC as a EuropeanStandard without any modification. _ EN 61300-2-50:2007 2BS EN 61300-2-50:2007 3 EN 61300-2-50:2007CONTENTS 1Scope 42Norma

19、tive references .43General description44Apparatus 45Procedure55.1 General.55.2 Preparation of specimen65.3 Preconditioning .65.4 Initial measurements .65.5 Test method65.6 Recovery.65.7 Final measurements66Details to be specified7 Annex ZA (normative) Normative references to international publicatio

20、ns with their corresponding European publications .8Figure 1 Proof test apparatus.5Figure 2 Application of the load in the case of duplex cordage5BS EN 61300-2-50:2007EN 61300-2-50:2007 4 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-50: Test

21、s Fibre opticconnector proof test with static load Singlemode and multimode 1 Scope This part of IEC 61300 describes a test to quantitatively assess the capability of connector terminated patchcord cable assemblies to withstand static loads without uncoupling of the connector, physical damage to the

22、 assembly or permanent degradation of optical performance. This test is intended to apply to terminated reinforced jacketed cable of any diameter, both singlemode and multimode. 2 Normative references The following referenced documents are indispensable for the application of this document. For date

23、d references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 1: General and guidance IEC 61300

24、-3-1, Fiber optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinations and measurements Visual examinationIEC 61300-3-6, Fiber optic interconnecting devices and passive components Basic test and measurement procedures Part 3-6: Examinations and

25、measurements Return Loss IEC 61300-3-34, Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors3 General description Static loads are applied to the cable of a patchcord as

26、sembly at 0 (straight pull) and at 90(side pull) to the connector axis and held for a fixed time, while the mated connector assembly is held fixed by the adapter. The sample is examined and measured for attenuation and return loss before and after each load is applied. 4 Apparatus The apparatus for

27、this testis shown in Figure 1. The patchcord tension is applied with weights through a capstan. The patchcord is flexed at the point of entrance to the connector plug by rotating the test arm. The position of the connector assembly along the test arm should be adjusted so that, when the arm is at 90

28、, the centerline along which the cable hangs passes through the test point. The fixture is to be designed to allow the capstan to be rotated about the axis of the section of cable under tension. BS EN 61300-2-50:2007IEC 61300-3-4, Fibre optic interconnecting devices and passive components Basic test

29、 and measurement procedures Part 3-4: Examinations and measurements Attenuation 5 EN 61300-2-50:2007The bracket on which the adapter is mounted is to have provision for mounting the adapter at angles of 0 and 90 to the axis of the connector. Test armFor proof, angle is 0 and 90 (only 90 shown) Pivot

30、 pointof test armConnector GuidesWeights20 cm-28 cmCapstan 7,5 cmJumper cableIEC 953/07 Figure 1 Proof test apparatus In the case of duplex cordage, the loads shall not be doubled and the cordage shall be bent in the minor axis direction as shown in Figure 2. Load Duplex cordage IEC 954/07Figure 2 A

31、pplication of the load in the case of duplex cordage 5 Procedure 5.1 General The following procedure shall be used in this test. The loads to be applied are those designated in the relevant specification at a rate of 5 N/s for reinforced cables. If these are not specified the following preferred loa

32、ds may be used: For small form factor connectors the preferred load at 90 is 2/3 of the specified values. Straight pull, 0: 44,5 N BS EN 61300-2-50:2007EN 61300-2-50:2007 6 Side pull, 90: 22,6 N All optical measurements shall be made for singlemode at 1 310 nm and 1 550 nm wavelengths and multimode

33、at 850 nm and 1 300 nm wavelengths. Optional: singlemode at 1 625 nm, or as specified for the appropriate technology (for example, multimode at 650 nm). 5.2 Preparation of specimen Prepare and clean the specimen in accordance with the manufacturers instructions. 5.3 Preconditioning Pre-condition the

34、 specimen for 2 h at the standard test conditions as defined in IEC 61300-1, unless otherwise specified in the relevant specification. 5.4 Initial measurements Complete initial examinations and measurements on the specimen as required by the relevant specification. 5.5 Test method 5.5.1 Mount the sp

35、ecimen in the apparatus shown in Figure 1. 5.5.2 Measure attenuation and return loss as described in IEC 61300-3-6 and 61300-3-34 respectively. 5.5.3 Straight pull, 05.5.3.1 Apply the load specified in the relevant specification for a minimum of 5 s. Record whether or not the connector uncouples. Re

36、cord whether or not the cable assembly sustains damage and, if so, record a description of the damage. 5.5.3.2 Remove the load and wait a minimum of 10 s. 5.5.3.3 Measure attenuation and return loss. 5.5.4 Side pull, 905.5.4.1 Apply the load specified in the relevant specification for a minimum of 5

37、 s. Record whether or not the connector uncouples. Record whether or not the cable assembly sustains damage and, if so, record a description of the damage in accordance with 61300-3-1. 5.5.4.2 Remove the load and wait a minimum of 20 s. 5.5.4.3 Measure attenuation and return loss as described in IEC

38、 61300-3-6 and 61300-3-34 respectively. 5.6 RecoveryAllow the specimen to remain under standard test conditions for 2 h, as defined in IEC 61300-1, unless otherwise specified in the relevant specification. Clean the specimen in accordance with the manufacturers instructions. 5.7 Final measurements O

39、n completion of the test, remove all fixtures and make final measurements, as defined by the relevant specification, to ensure that there is no permanent damage to the specimen. BS EN 61300-2-50:2007Measure attenuation and return loss as described in IEC 61300-3-4 and IEC 61300-3-6 respectively.5.5.

40、4.3 Measure attenuation and return loss as described in IEC 61300-3-4 and IEC 61300-3-6 respectively. 7 EN 61300-2-50:20076 Details to be specified The following details, as applicable, shall be specified in the relevant specification: initial examinations, measurements and performance requirements;

41、 final examinations, measurements and performance requirements; if the connector uncoupled under load; load applied at 0 and 90; singlemode wavelengths 1 310 nm and 1 550 nm, optional 1 625 nm or as specified; multimode wavelength 850 nm and 1 300 nm, or as specified; deviation from test procedures.

42、 _ BS EN 61300-2-50:2007EN 61300-2-50:2007 8 Annex ZA (normative) Normative references to international publications with their corresponding European publicationsThe following referenceddocuments are indispensable for the application of this document. For datedreferences, only the edition cited app

43、lies. For undated references, the latest edition of the referenceddocument (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HDapplies. Publication Year Title EN/HD YearIEC 61300-1-1)Fibre optic i

44、nterconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance EN 61300-1 20032)IEC 61300-3-1 -1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual

45、 examination EN 61300-3-1 20052)IEC 61300-3-6 -1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return lossEN 61300-3-6 20032)IEC 61300-3-34 -1)Fibre optic interconnecting devices and passive components -

46、 Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors EN 61300-3-34 20022)1)Undated reference. 2)Valid edition at date of issue. BS EN 61300-2-50:2007blankBSI is the national body responsible for preparing British Standards and oth

47、er standards-related publications, information and services.BSI is incorporated by Royal Charter. British Standards and other standardization products are published by BSI Standards Limited.British Standards Institution (BSI)BSI Group Headquarters389 Chiswick High Road London W4 4AL UKAbout usWe bri

48、ng together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions.The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process. Organizations of all sizes and across all sectors choose standards to help them achieve their goals.Information on standardsWe can provide you with the knowledge that your organization needs to succeed. Find out more about British Standards by visiting our website at bsigroup.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1