EN 62053-11-2003 en Electricity metering equipment (a c ) Particular requirements Part 11 Electromechanical meters for active energy (classes 0 5 1 and 2) (Incorporates Amendment A.pdf

上传人:rimleave225 文档编号:720908 上传时间:2019-01-04 格式:PDF 页数:20 大小:461.93KB
下载 相关 举报
EN 62053-11-2003 en Electricity metering equipment (a c ) Particular requirements Part 11 Electromechanical meters for active energy (classes 0 5 1 and 2) (Incorporates Amendment A.pdf_第1页
第1页 / 共20页
EN 62053-11-2003 en Electricity metering equipment (a c ) Particular requirements Part 11 Electromechanical meters for active energy (classes 0 5 1 and 2) (Incorporates Amendment A.pdf_第2页
第2页 / 共20页
EN 62053-11-2003 en Electricity metering equipment (a c ) Particular requirements Part 11 Electromechanical meters for active energy (classes 0 5 1 and 2) (Incorporates Amendment A.pdf_第3页
第3页 / 共20页
EN 62053-11-2003 en Electricity metering equipment (a c ) Particular requirements Part 11 Electromechanical meters for active energy (classes 0 5 1 and 2) (Incorporates Amendment A.pdf_第4页
第4页 / 共20页
EN 62053-11-2003 en Electricity metering equipment (a c ) Particular requirements Part 11 Electromechanical meters for active energy (classes 0 5 1 and 2) (Incorporates Amendment A.pdf_第5页
第5页 / 共20页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN 62053-11:2003 Incorporating Corrigendum No. 1 Electricity metering equipment (a.c.) Particular requirements Part 11: Electromechanical meters for active energy (classes 0,5, 1 and 2) The European Standard EN 62053-11:2003 has the status of a British Standard ICS 17.220.20 BS E

2、N 62053-11:2003 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 4 July 2003 BSI 24 February 2004 ISBN 0 580 42186 4 National foreword This British Standard is the official English language version of EN 62053-11:2003. It is identical with IEC

3、 62053-11:2003. It supersedes BS EN 60521:1995 which is obsolescent and will be withdrawn on 1 March 2006. The UK participation in its preparation was entrusted to Technical Committee PEL/13, Electricity meters, which has the responsibility to: A list of organizations represented on this committee c

4、an be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search”

5、 facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal oblig

6、ations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary o

7、f pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 16, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date Comments 150

8、25 Corrigendum No. 1 24 February 2004 Correction to supersession informationEUROPEAN STANDARD EN 62053-11 NORME EUROPENNE EUROPISCHE NORM March 2003 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnisch

9、e Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62053-11:2003 E ICS 17.220.20 Supersedes EN 60521:1995English version Electricity metering equipment (a.c.)

10、Particular requirements Part 11: Electromechanical meters for active energy (classes 0,5, 1 and 2) (IEC 62053-11:2003) Equipement de comptage de llectricit (c.a.) Prescriptions particulires Partie 11: Compteurs lectromcaniques dnergie active (classes 0,5, 1 et 2) (CEI 62053-11:2003) Wechselstrom-Ele

11、ktrizittszhler - Besondere Anforderungen Teil 11: Elektromechanische Wirkverbrauchszhler der Genauigkeitsklassen 0,5, 1 und 2 (IEC 62053-11:2003) This European Standard was approved by CENELEC on 2003-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulat

12、e the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard e

13、xists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national el

14、ectrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. EN 65023-1102:30 - - 2 Foreword The text of document

15、13/1287/FDIS, future edition 1 of IEC 62053-11, prepared by IEC TC 13, Equipment for electrical energy measurement and load control, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 62053-11 on 2003-03-01. This European Standard supersedes EN 60521:1995 + corrigendum

16、December 1997. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2003-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2006-0

17、3-01 Annexes designated “normative“ are part of the body of the standard. In this standard, annex ZA is normative. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 62053-11:2003 was approved by CENELEC as a European Standard without any modification

18、. _ Page2 EN6205311:2003 CONTENTS INTRODUCTION.4 1 Scope.5 2 Normative references5 3 Terms and definitions5 4 Standard electrical values.6 5 Mechanical Requirements.6 5.1 General.6 5.2 Register (counting mechanism).6 5.3 Direction of rotation and marking of the rotor.6 6 Climatic conditions6 7 Elect

19、rical requirements.6 7.1 Power consumption.6 7.2 Influence of short-time overcurrents 7 7.3 Influence of self-heating 8 7.4 AC voltage test8 8 Accuracy requirements10 8.1 Limits of error due to variation of the current .10 8.2 Limits of error due to influence quantities 10 8.3 Test of starting and n

20、o-load condition12 8.4 Meter constant12 8.5 Accuracy test conditions12 8.6 Interpretation of test results.14 9 Adjustment14 Annex ZA (normative) Normative references to international publications with their corresponding European publications .16 Table 1 Power consumption in voltage circuits.7 Table

21、 2 Power consumption in current circuits .7 Table 3 Variations due to short-time overcurrents 8 Table 4 Variations due to self-heating8 Table 5 AC voltage tests9 Table 6 Percentage error limits (single-phase meters and polyphase meters with balanced loads) 10 Table 7 Percentage error limits (polypha

22、se meters carrying a single-phase load, but with balanced polyphase voltages applied to voltage circuits) .10 Table 8 Influence quantities .11 Table 9 Starting current .12 Table 10 Voltage and current balance13 Table 11 Reference conditions.13 Table 12 Interpretation of test results.14 Table 13 Mini

23、mum range of adjustment15 Page3 EN6205311:2003 INTRODUCTION This part of IEC 62053 is to be used with the following relevant parts of the IEC 62052, IEC 62053 and IEC 62059 series, Electricity metering equipment: IEC 62052-11:2003, Electricity metering equipment (a.c.) General requirements, tests an

24、d test conditions Part 11: Metering equipment IEC 62053-21:2003, Electricity metering equipment (a.c.) Particular requirements Part 21: Static meters for active energy (classes 1 and 2) Replaces particular requirements of IEC 61036: 2000 (2 ndedition) IEC 62053-22:2003, Electricity metering equipmen

25、t (a.c.) Particular requirements Part 22: Static meters for active energy (classes 0,2 S and 0,5 S) Replaces particular requirements of IEC 60687: 1992 (2 ndedition) IEC 62053-23:2002, Electricity metering equipment (a.c.) Particular requirements Part 23: Static meters for reactive energy (classes 2

26、 and 3) Replaces particular requirements of IEC 61268: 1995 (1 stedition) IEC 62053-31:1998, Electricity metering equipment (a.c.) Particular requirements Part 31: Pulse output devices for electromechanical and electronic meters (two wires only) IEC 62053-61:1998, Electricity metering equipment (a.c

27、.) Particular requirements Part 61: Power consumption and voltage requirements IEC 62059-11:2002, Electricity metering equipment (a.c.) Dependability Part 11: General concepts IEC 62059-21:2002, Electricity metering equipment (a.c.) Dependability Part 21: Collection of meter dependability data from

28、the field This part is a standard for type testing electricity meters. It covers the particular requirements for meters, being used indoors and outdoors in large quantities world-wide. It does not deal with special implementations (such as metering-part and/or displays in separate housings). This st

29、andard is intended to be used in conjunction with IEC 62052-11. When any requirement in this standard concerns an item already covered in IEC 62052-11, the requirements of this standard take precedence over the requirements of IEC 62052-11. This standard distinguishes: between accuracy class index 0

30、,5, accuracy class index 1 and accuracy class index 2 meters; between protective class I and protective class II meters; between meters for use in networks equipped with or without earth fault neutralizers. The test levels are regarded as minimum values that provide for the proper functioning of the

31、 meter under normal working conditions. For special application, other test levels might be necessary and should be agreed on between the user and the manufacturer. Page4 EN6205311:2003 ELECTRICITY METERING EQUIPMENT (AC) PARTICULAR REQUIREMENTS Part 11: Electromechanical meters for active energy (c

32、lasses 0,5, 1 and 2) 1 Scope This part of IEC 62053 applies only to newly manufactured electromechanical watt-hour meters of accuracy classes 0,5, 1 and 2, for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only. It appli

33、es only to electromechanical watt-hour meters for indoor and outdoor application consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has a measuring element for more than one type of energy (m

34、ulti-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces, etc. are enclosed in the meter case, then the relevant standards for these elements also apply. It does not app

35、ly to: watt-hour meters where the voltage across the connection terminals exceeds 600 V (line- to-line voltage for meters for polyphase systems); portable meters; data interfaces to the register of the meter. Regarding acceptance tests, a basic guideline is given in IEC 60514. The dependability aspe

36、ct is covered by the documents of the IEC 62059 series. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (inclu

37、ding any amendments) applies. IEC 60514:1975, Acceptance inspection of Class 2 alternating-current watt-hour meters IEC 60736:1982, Testing equipment for electrical energy meters IEC 62052-11:2003, Electricity metering equipment (a.c.) General requirements, tests and test conditions Part 11: Meterin

38、g equipment 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 62052-11 apply. Page5 EN6205311:2003 4 Standard electrical values The values given in IEC 62052-11 apply. 5 Mechanical requirements In addition to the mechanical requirements in IEC 62052-11

39、, electromechanical meters shall fullfil the following requirements. 5.1 General The case of an electromechanical watt-hour meter shall be so constructed that, if mounted according to the manufacturers instructions, the meter shall not deviate by more than 0,5 in all directions from its vertical pos

40、ition (see also note 2 of Table 11). 5.2 Register (counting mechanism) The register may be of the drum or the pointer type. In drum-type registers, the principal unit in which the register records shall be marked adjacent to the set of drums. In this type of register, only the last drum, i.e. the dr

41、um on the extreme right, may be continuously movable. In pointer-type registers, the unit in which the register records shall be marked adjacent to the units dial in the form: 1 kWh/div, or 1 MWh/div, and the decimal multiples may be marked adjacent to the other dials. For example, in a meter regist

42、ering in terms of kilowatthours, the units dial shall be marked: 1 kWh/div and, adjacent to the other dials to the left of the units dial, shall be marked: 10 100 1 000, etc. 5.3 Direction of rotation and marking of the rotor The edge of the rotor nearest to an observer viewing a meter from the fron

43、t shall move from left to right for positive registration. The direction of rotation shall be marked by a clearly visible arrow. The edge and/or upper surface of the disk shall carry an easily visible mark to facilitate revolution counting. Other marks may be added for stroboscopic or other tests, b

44、ut such marks shall be so placed as not to interfere with the use of the main visible mark for photoelectric revolution counting. 6 Climatic conditions The conditions given in IEC 62052-11 apply. 7 Electrical requirements In addition to the electrical requirements in IEC 62052-11, meters shall fulfi

45、l the following requirements. 7.1 Power consumption The power consumption in the voltage and current circuit shall be determined at reference conditions given in 8.5 by any suitable method. The overall maximum error of the measurement of the power consumption shall not exceed 5 %. Page6 EN6205311:20

46、03 7.1.1 Voltage circuits The active and apparent power consumption in each voltage circuit of a meter at reference voltage, reference temperature and reference frequency shall not exceed the values shown in Table 1. Table 1 Power consumption in voltage circuits Class of meter Meters 0,5 and 1 2 Sin

47、gle-phase and polyphase 3 W and 12 VA 2 W and 10 VA NOTE In order to match voltage transformers to meters, the meter manufacturer should state whether the burden is inductive or capacitive (for transformer operated meters only). 7.1.2 Current circuits The apparent power taken by each current circuit

48、 of a direct connected meter at basic current, reference frequency and reference temperature shall not exceed the values shown in Table 2. The apparent power taken by each current circuit of a meter connected through a current transformer shall not exceed the value shown in Table 2 at a current valu

49、e that equals the rated secondary current of the corresponding transformer, at reference temperature and reference frequency of the meter. Table 2 Power consumption in current circuits Class of meter Meters Basic current I b0,5 1 2 30 A 6,0 VA 4,0 VA 2,5 VA Single-phase and polyphase 30 A 10,0 VA 6,0 VA 4,0 VA NOTE 1 The rated secondary current is the value of the se