NACE 01105-2005 Sacrificial Cathodic Protection of Reinforced Concrete Elements- A State-of-the-Art Report (Item No 24224)《钢筋混凝土元件的牺牲阴极保护 技术现状报告项目编号24224》.pdf

上传人:bowdiet140 文档编号:835693 上传时间:2019-02-20 格式:PDF 页数:15 大小:394.65KB
下载 相关 举报
NACE 01105-2005 Sacrificial Cathodic Protection of Reinforced Concrete Elements- A State-of-the-Art Report (Item No 24224)《钢筋混凝土元件的牺牲阴极保护 技术现状报告项目编号24224》.pdf_第1页
第1页 / 共15页
NACE 01105-2005 Sacrificial Cathodic Protection of Reinforced Concrete Elements- A State-of-the-Art Report (Item No 24224)《钢筋混凝土元件的牺牲阴极保护 技术现状报告项目编号24224》.pdf_第2页
第2页 / 共15页
NACE 01105-2005 Sacrificial Cathodic Protection of Reinforced Concrete Elements- A State-of-the-Art Report (Item No 24224)《钢筋混凝土元件的牺牲阴极保护 技术现状报告项目编号24224》.pdf_第3页
第3页 / 共15页
NACE 01105-2005 Sacrificial Cathodic Protection of Reinforced Concrete Elements- A State-of-the-Art Report (Item No 24224)《钢筋混凝土元件的牺牲阴极保护 技术现状报告项目编号24224》.pdf_第4页
第4页 / 共15页
NACE 01105-2005 Sacrificial Cathodic Protection of Reinforced Concrete Elements- A State-of-the-Art Report (Item No 24224)《钢筋混凝土元件的牺牲阴极保护 技术现状报告项目编号24224》.pdf_第5页
第5页 / 共15页
点击查看更多>>
资源描述

1、Item No. 24224 NACE International Publication 01105 This Technical Committee Report has been prepared By NACE International Task Group 047* on Concrete and Rebar Sacrificial Cathodic Protection of Reinforced Concrete Elements A State-of-the-Art Report March 2005, NACE International This NACE Interna

2、tional technical committee report represents a consensus of those individual members who have reviewed this document, its scope, and provisions. Its acceptance does not in any respect preclude anyone from manufacturing, marketing, purchasing, or using products, processes, or procedures not included

3、in this report. Nothing contained in this NACE report is to be construed as granting any right, by implication or otherwise, to manufacture, sell, or use in connection with any method, apparatus, or product covered by Letters Patent, or as indemnifying or protecting anyone against liability for infr

4、ingement of Letters Patent. This report should in no way be interpreted as a restriction on the use of better procedures or materials not discussed herein. Neither is this report intended to apply in all cases relating to the subject. Unpredictable circumstances may negate the usefulness of this rep

5、ort in specific instances. NACE assumes no responsibility for the interpretation or use of this report by other parties. Users of this NACE report are responsible for reviewing appropriate health, safety, environmental, and regulatory documents and for determining their applicability in relation to

6、this report prior to its use. This NACE report may not necessarily address all potential health and safety problems or environmental hazards associated with the use of materials, equipment, and/or operations detailed or referred to within this report. Users of this NACE report are also responsible f

7、or establishing appropriate health, safety, and environmental protection practices, in consultation with appropriate regulatory authorities if necessary, to achieve compliance with any existing applicable regulatory requirements prior to the use of this report. CAUTIONARY NOTICE: The user is caution

8、ed to obtain the latest edition of this report. NACE reports are subject to periodic review, and may be revised or withdrawn at any time without prior notice. NACE reports are automatically withdrawn if more than 10 years old. Purchasers of NACE reports may receive current information on all NACE In

9、ternational publications by contacting the NACE FirstService Department, 1440 South Creek Drive, Houston, Texas 77084-4906 (telephone +1 281/228-6200). Foreword The purpose of this technical committee report is to present state-of-the-art information on several commercially available galvanic cathod

10、ic protection/prevention systems for protecting atmospherically exposed reinforced concrete structures. A summary of these systems is presented in Appendix A. It is beyond the scope of this report to fully address all factors associated with design, criteria, implementation, quality control, cost, m

11、aintenance, and monitoring of these systems. The information contained in this report has been provided by key manufacturers of these systems and is intended as a technical resource for engineers responsible for the rehabilitation of reinforced concrete structures. It may also be useful to owners, c

12、ontractors, and other practitioners related to the field of galvanic cathodic protection (CP). All information as it relates to galvanic CP is intended for atmospherically exposed concrete structures and is not applicable to concrete containing epoxy-coated reinforcing steel, galvanized, or other co

13、ated or nonferrous reinforcement. Galvanic CP has also been successfully applied to buried or submerged reinforced concrete structures; however, this aspect is not addressed in this state-of-the-art report. This NACE technical committee report was prepared by Task Group (TG) 047 on Sacrificial Catho

14、dic Protection of Reinforced Concrete Elements. This TG is administered by Specific Technology Group (STG) 01 on Concrete and Rebar. It is also sponsored by STG 05 on Cathodic/Anodic Protection. This report is issued by NACE International under the auspices of STG 01. _ *Chairman Doug Leng, Southern

15、 Cathodic Protection, Atlanta, Georgia. NACE International 2Introduction Over the past several decades the corrosion of steel reinforcement embedded in concrete structures has received considerable worldwide attention. In theory, concrete and reinforcing steel are very compatible. They have similar

16、coefficients of thermal expansion. Concrete, because of its highly alkaline nature, creates a protective environment for the steel. Studies have shown that corrosion activity and damage result when critical quantities of aggressive ions penetrate through the concrete pore structure by diffusion and

17、other transport phenomena and reach the embedded steel reinforcement. At this time, the naturally occurring passive film developed by highly alkaline concrete becomes saturated with these ions, eventually breaking down this protective layer. In regions of low resistance, aggressive ions, mostly in t

18、he form of salts, attack the passive film and develop localized anodic sites (pits) on the surface of the steel. Immediately adjacent to these anodic sites are oxygen-rich regions that cathodically “fuel” the corrosion reaction. As active corrosion proceeds, the lower pH in and around the anodic sit

19、es reduces the passive layer in greater proportions, making it more prone to iron oxide (Fe2O3) development. Because Fe2O3(rust) is much more voluminous than solid steel, it imparts considerable tensile forces within the concrete matrix and eventually leads to cracking of the concrete cover. There a

20、re several approaches that have been used to rehabilitate concrete structures suffering from the effects of corrosion damage. The most widely used approach typically involves removing the damaged concrete in and around the affected area and replacing it to the original dimension. The principal inten

21、t of this remove-and-replace approach is to return the form and function of the structure. Although this strategy is widely used, it rarely incorporates the complete removal of contaminated areas that surround the damaged region, and is sometimes regarded as only a short-term solution. Modifications

22、 to this technique include expanding the area excavated to include sound but chloride-contaminated or carbonated concrete, or to include areas where the steel-reinforcement potential is more negative than a defined threshold. The remove-and-replace approach is normally broken into two general catego

23、ries. The first is patch repair, and the second is rehabilitation. Patch repair is a short-term solution that makes no attempt to extend the structure life, but merely restores concrete back to dimension. The rehabilitation technique attempts to return the distressed area to uniformity with the pre-

24、existing conditions and normalizes any conditions of further distress. The rehabilitation technique carries with it some expectation of an increase in service life. In some applications, a corrosion inhibitor is included either as an additive to the repair/replacement concrete mix or as a post treat

25、ment. These methods of concrete repair are much more involved than discussed in this report and are well integrated into most structure owner agencies and the civil engineering community. Alternatively, CP applies electrochemistry to halt the corrosion process or reduce it to levels below engineerin

26、g significance. Cathodic protection is an electrochemical technique used to reduce the corrosion of metallic materials. This is accomplished through the addition of a cathodic current to the metal-electrolyte system so as to increase the rate of the cathodic reaction (the formation of hydrogen H2 or

27、 hydroxide OH-) on the metal being protected, and at the same time decrease the rate of the anodic reaction (metal dissolution). The source of this cathodic current is immaterial to the protection process, and can come from direct current (DC), alternating current (AC), or galvanic sources. Definiti

28、ons Anode: The electrode of an electrochemical cell at which oxidation occurs. Electrons flow away from the anode in the external circuit. Corrosion usually occurs and metal ions enter the solution at the anode. Anodic Polarization: The change of the electrode potential in the noble (positive) direc

29、tion caused by current across the electrode/electrolyte interface. (See Polarization.) Cathode: The electrode of an electrochemical cell at which reduction is the principal reaction. Electrons flow toward the cathode in the external circuit. Cathodic Prevention: The application of cathodic polarizat

30、ion to passive steel to prevent or delay a transition to the actively corroding condition. Cathodic Protection: A technique to reduce the corrosion of a metal surface by making that surface the cathode of an electrochemical cell. Conductive Concrete: A highly conductive cement-based mixture containi

31、ng coarse and fine coke and other material used as an impressed current anode on reinforced concrete surfaces. NACE technical committee reports are intended to convey technical information or state-of-the-art knowledge regarding corrosion. In many cases, they discuss specific applications of corrosi

32、on mitigation technology, whether considered successful or not. Statements used to convey this information are factual and are provided to the reader as input and guidance for consideration when applying this technology in the future. However, these statements are not intended to be recommendations

33、for general application of this technology, and must not be construed as such. NACE International 3Current: (1) A flow of electric charge. (2) The amount of electric charge flowing past a specified circuit point per unit time, measured in the direction of net transport of positive charges. (In a met

34、allic conductor, this is the opposite direction of the electron flow.) Current Density: The current to or from a unit area of an electrode surface. Depolarization: The removal of factors resisting the current in an electrochemical cell. Dissimilar Metals: Different metals that could form an anode-ca

35、thode relationship in an electrolyte when connected by a metallic path. Electrochemical Cell: A system consisting of an anode and a cathode immersed in an electrolyte so as to create an electrical circuit. The anode and cathode may be different metals or dissimilar areas on the same metal surface. E

36、lectrochemical Potential: The partial derivative of the total electrochemical free energy of a constituent with respect to the number of moles of this constituent where all other factors are kept constant. It is analogous to the chemical potential of a constituent except that it includes the electri

37、cal as well as chemical contributions to the free energy. Electrode: A conductor used to establish contact with an electrolyte and through which current is transferred to or from an electrolyte. Electrode Potential: The potential of an electrode in an electrolyte as measured against a reference elec

38、trode. (The electrode potential does not include any resistance losses in potential in either the electrolyte or the external circuit. It represents the reversible work to move a unit of charge from the electrode surface through the electrolyte to the reference electrode.) Electrolyte: A chemical su

39、bstance containing ions that migrate in an electric field. Embrittlement: Loss of ductility of a material resulting from a chemical or physical change. Galvanic Anode: A metal that provides sacrificial protection to another metal that is more noble when electrically coupled in an electrolyte. This t

40、ype of anode is the electron source in one type of cathodic protection. Half-Cell: A pure metal in contact with a solution of known concentration of its own ion, at a specific temperature, develops a potential that is characteristic and reproducible; when coupled with another half-cell, an overall p

41、otential that is the sum of both half-cells develops. Half-Cell Potential: The potential in a given electrolyte of one electrode of a pair relative to a standard state or a reference state. Potentials can only be measured and expressed as the difference between the half-cell potentials of a pair of

42、electrodes. Humectant: A substance that promotes retention of moisture. Hydrogen Embrittlement: A loss of ductility of a metal resulting from absorption of hydrogen. Hydrogen Overvoltage: Overvoltage associated with the liberation of hydrogen gas. Impressed Current: An electric current supplied by a

43、 device employing a power source that is external to the electrode system. (An example is direct current for cathodic protection.) Metallizing: The coating of a surface with a thin metal layer by spraying, hot dipping, or vacuum deposition. Overvoltage: The change in potential of an electrode from i

44、ts equilibrium or steady-state value when current is applied. Passive: (1) The positive direction of electode potential. (2) A state of a metal in which a surface reaction product causes a marked decrease in the corrosion rate relative to that in the absence of the product. pH: The negative logarith

45、m of the hydrogen ion activity written as: pH = -log10(aH+) where aH+= hydrogen ion activity = the molar concentration of hydrogen ions multiplied by the mean ion-activity coefficient. Polarization: The change from the open-circuit potential as a result of current across the electrode/electrolyte in

46、terface. Polarization Decay: The decrease in electrode potential with time resulting from the interruption of applied current. Reference Electrode: An electrode whose open-circuit potential is constant under similar conditions of measurement, which is used for measuring the relative potentials of ot

47、her electrodes. Relative Humidity: The ratio, expressed as a percentage, of the amount of water vapor present in a given volume of air at a given temperature to the amount required to saturate the air at that temperature. Resistivity: (1) The resistance per unit length of a substance with uniform cr

48、oss section. (2) A measure of the ability of an electrolyte (e.g., soil) to resist the flow of electric charge (e.g., cathodic protection current). Resistivity data are used to design a groundbed for a cathodic protection system. NACE International 4Stress Corrosion Cracking: Cracking of a material

49、produced by the combined action of corrosion and tensile stress (residual or applied). Thermal Spraying: A group of processes by which finely divided metallic or nonmetallic materials are deposited in a molten or semimolten condition to form a coating. General The Principles of Cathodic Protection In 1981, the Federal Highway Administration (FHWA)(1)issued a statement describing CP as the only rehabilitation technique proven to stop corrosion in salt-contaminated structures, regardless of chloride content in the concrete.1There are two forms of CP: impresse

展开阅读全文
相关资源
猜你喜欢
  • DIN EN ISO 17697-2016 Footwear - Test methods for uppers lining and insocks - Seam strength (ISO 17697 2016) German version EN ISO 17697 2016《鞋靴 鞋帮、鞋衬和内垫的试验方法 缝口强度(ISO 17697-2016) .pdf DIN EN ISO 17697-2016 Footwear - Test methods for uppers lining and insocks - Seam strength (ISO 17697 2016) German version EN ISO 17697 2016《鞋靴 鞋帮、鞋衬和内垫的试验方法 缝口强度(ISO 17697-2016) .pdf
  • DIN EN ISO 17698-2016 Footwear - Test methods for uppers - Delamination resistance (ISO 17698 2016) German version EN ISO 17698 2016《鞋靴 鞋帮的试验方法 耐剥离性(ISO 17698-2016) 德文版本EN ISO 1769.pdf DIN EN ISO 17698-2016 Footwear - Test methods for uppers - Delamination resistance (ISO 17698 2016) German version EN ISO 17698 2016《鞋靴 鞋帮的试验方法 耐剥离性(ISO 17698-2016) 德文版本EN ISO 1769.pdf
  • DIN EN ISO 177-2017 Plastics - Determination of migration of plasticizers (ISO 177 2016) German version EN ISO 177 2017《塑料 增塑剂分散性的测定(ISO 177-2016) 德文版本EN ISO 177-2017》.pdf DIN EN ISO 177-2017 Plastics - Determination of migration of plasticizers (ISO 177 2016) German version EN ISO 177 2017《塑料 增塑剂分散性的测定(ISO 177-2016) 德文版本EN ISO 177-2017》.pdf
  • DIN EN ISO 17700-2005 Footwear - Test methods for uppers linings and insocks - Colour fastness to rubbing (ISO 17700 2004) English version of DIN EN ISO 17700 2005《鞋靴 鞋帮、鞋衬和鞋内衬试验方法.pdf DIN EN ISO 17700-2005 Footwear - Test methods for uppers linings and insocks - Colour fastness to rubbing (ISO 17700 2004) English version of DIN EN ISO 17700 2005《鞋靴 鞋帮、鞋衬和鞋内衬试验方法.pdf
  • DIN EN ISO 17701-2016 Footwear - Test methods for uppers lining and insocks - Colour migration (ISO 17701 2016) German version EN ISO 17701 2016《鞋类 鞋帮、鞋衬和内垫的试验方法 色移(ISO 17701-2016).pdf DIN EN ISO 17701-2016 Footwear - Test methods for uppers lining and insocks - Colour migration (ISO 17701 2016) German version EN ISO 17701 2016《鞋类 鞋帮、鞋衬和内垫的试验方法 色移(ISO 17701-2016).pdf
  • DIN EN ISO 17707-2005 Footwear - Test methods for outsoles - Flex resistance (ISO 17707 2005) English version of DIN EN ISO 17707《鞋靴 外底试验方法 耐弯性》.pdf DIN EN ISO 17707-2005 Footwear - Test methods for outsoles - Flex resistance (ISO 17707 2005) English version of DIN EN ISO 17707《鞋靴 外底试验方法 耐弯性》.pdf
  • DIN EN ISO 17708-2003 Footwear - Test methods for whole shoe - Upper sole adhesion (ISO 17708 2003) German Version EN ISO 17708 2003《鞋靴 整鞋的试验方法 上部鞋底的附着力》.pdf DIN EN ISO 17708-2003 Footwear - Test methods for whole shoe - Upper sole adhesion (ISO 17708 2003) German Version EN ISO 17708 2003《鞋靴 整鞋的试验方法 上部鞋底的附着力》.pdf
  • DIN EN ISO 17715-2015 Flour from wheat (Triticum aestivum L ) - Amperometric method for starch damage measurement (ISO 17715 2013) German version EN ISO 17715 2014《小麦粉 (普通小麦Triticu.pdf DIN EN ISO 17715-2015 Flour from wheat (Triticum aestivum L ) - Amperometric method for starch damage measurement (ISO 17715 2013) German version EN ISO 17715 2014《小麦粉 (普通小麦Triticu.pdf
  • DIN EN ISO 17718-2015 Wholemeal and flour from wheat (Triticum aestivum L ) - Determination of rheological behaviour as a function of mixing and temperature increase (ISO 17718 201.pdf DIN EN ISO 17718-2015 Wholemeal and flour from wheat (Triticum aestivum L ) - Determination of rheological behaviour as a function of mixing and temperature increase (ISO 17718 201.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1