ASD-STAN PREN 2267-010-2015 Aerospace series Cables electrical for general purpose Operating temperatures between - 55 °C and 260 °C Part 010 DR family single UV laser printable Pr.pdf

上传人:testyield361 文档编号:450878 上传时间:2018-11-23 格式:PDF 页数:9 大小:379.24KB
下载 相关 举报
ASD-STAN PREN 2267-010-2015 Aerospace series Cables electrical for general purpose Operating temperatures between - 55 °C and 260 °C Part 010 DR family single UV laser printable Pr.pdf_第1页
第1页 / 共9页
ASD-STAN PREN 2267-010-2015 Aerospace series Cables electrical for general purpose Operating temperatures between - 55 °C and 260 °C Part 010 DR family single UV laser printable Pr.pdf_第2页
第2页 / 共9页
ASD-STAN PREN 2267-010-2015 Aerospace series Cables electrical for general purpose Operating temperatures between - 55 °C and 260 °C Part 010 DR family single UV laser printable Pr.pdf_第3页
第3页 / 共9页
ASD-STAN PREN 2267-010-2015 Aerospace series Cables electrical for general purpose Operating temperatures between - 55 °C and 260 °C Part 010 DR family single UV laser printable Pr.pdf_第4页
第4页 / 共9页
ASD-STAN PREN 2267-010-2015 Aerospace series Cables electrical for general purpose Operating temperatures between - 55 °C and 260 °C Part 010 DR family single UV laser printable Pr.pdf_第5页
第5页 / 共9页
亲,该文档总共9页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、ASD-STAN STANDARD NORME ASD-STAN ASD-STAN NORM prEN 2267-010 Edition P 3 September 2015 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Rue Montoyer 10 - 1000 Brussels - Tel. 32 2 775 8126 - Fax. 32 2 775 8131 - www.asd-stan.org ICS: Supersedes edition P 2 o

2、f June 2012 and will supersede EN 2267-010:2013 Descriptors: ENGLISH VERSION Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 010: DR family, single UV laser printable Product standard Srie arospatiale Cbles, lectriques, dusage gnral Temprat

3、ures de fonctionnement comprises entre 55 C et 260 C Partie 010 : Famille DR, fil simple marquable au laser UV Norme de produit Luft- und Raumfahrt Leitungen, elektrisch, fr allgemeine Verwendung Betriebstemperaturen zwischen 55 C und 260 C Teil 010: DR-Familie Einadrige Leitungen UV-Laser bedruckba

4、r Produktnorm This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts o

5、f the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by use

6、rs and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN t

7、he status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 1st September 2015 Comments should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2015 by ASD-STAN prEN 2267-010:2015

8、(E) 2 Contents Page Foreword 2 1 Scope 3 2 Normative references 3 3 Terms, definitions, symbols and abbreviations . 3 4 Materials and construction . 4 5 Required characteristics . 5 6 Quality assurance 8 7 Designation 8 8 Identification and marking 9 9 Packaging, labelling and delivery lengths 9 10

9、Technical specification . 9 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publ

10、ication. prEN 2267-010:2015 (E) 3 1 Scope This standard specifies the characteristics of UV laser printable electrical lightweight wires DR family for use in the on-board 115 V (phase to neutral) or 200 V (phase to phase) AC electrical systems of aircraft at operating temperatures between 65 C and 2

11、60 C. These cables are demonstrated to be arc resistant in sizes AWG 26 to 14 (115/200 V AC). In addition, these cables may be suitable for use at 230/400 V AC in pressurised zones only when installed to take account of possible short circuit effects. It shall also be possible to mark these cables b

12、y qualified compatible marking. These markings shall satisfy the requirements of EN 3838. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies.

13、For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2083, Aerospace series Copper or copper alloy conductors for electrical cables Product standard EN 2084, Aerospace series Cables, electrical, general purpose, with conductors in copper or cop

14、per alloy Technical specification EN 2267-002, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 002: General EN 3475 (all parts), Aerospace series Cables, electrical, aircraft use Test methods EN 3838, Aerospace series Requirements and tests

15、 on user-applied markings on aircraft electrical cables EN 4434, Aerospace series Copper or copper alloy lightweight conductors for electrical cables Product standard (Normal and tight tolerances) EN 9133, Aerospace series Quality management systems Qualification procedure for aerospace standard par

16、ts TR 6058, Aerospace series Cable code identification list 1) 3 Terms, definitions, symbols and abbreviations For the purposes of this document, the terms, definitions, symbols and abbreviations given in EN 3475-100 apply. 1) Published as ASD-STAN Technical Report at the date of publication of this

17、 standard. http:/www.asd-stan.org/ prEN 2267-010:2015 (E) 4 4 Materials and construction 4.1 Materials Conductor: These cable conductors shall be made of copper or copper alloy and nickel plated according to EN 4434 code D. Insulation: For all sizes codes shall be defined to satisfy all required cha

18、racteristics of Clause 5. For single core, it shall be possible to mark the outer layer of the insulation by UV laser printing. 4.2 Construction See EN 4434 and Table 1. Table 1 Code for nominal section Nominal section AWG a Linear resistance at 20 C External diameter Mass mm2 /km mm kg/km max. min.

19、 max. max. 001 0,15 26 160,0 0,75 0,84 2,08 002 0,25 24 114,0 0,85 0,96 2,72 004 0,4 22 60,0 1,00 1,10 4,14 006 0,6 20 33,2 1,22 1,34 6,85 010 1 18 21,1 1,46 1,61 10,43 012 1,2 16 14,5 1,76 1,92 14,61 020 2 14 10,9 2,04 2,24 19,78 030 3 12 6,8 2,50 2,70 31,33 051 5 10 4,1 3,13 3,33 49,85 090 9 8 2,3

20、 4,10 4,40 90,00 140 14 6 1,58 5,30 5,70 135,00 220 22 4 0,97 6,71 7,41 222,00 340 34 2 0,61 8,28 9,16 347,00 a AWG closest American Wire Gage. 4.3 Number of cores See EN 2267-002. 4.4 Colour coding of cores See EN 2267-002. prEN 2267-010:2015 (E) 5 5 Required characteristics According to EN 2084 an

21、d EN 3475-100. See Table 2. Table 2 (1 of 4) EN 3475- Designation of the test Details 201 Visual examination Applicable including laser marked specimen 202 Mass Applicable; see Table 1. 203 Dimensions Applicable; see Table 1. 301 Ohmic resistance per unit length Applicable; see Table 1. 302 Voltage

22、proof test Applicable 303 Insulation resistance Applicable 304 Surface resistance Applicable 305 Overload resistance Applicable T1 (310 5) C; T2 (450 5) C 306 Continuity of conductors Applicable 307 Corona extinction voltage Not applicable 401 Accelerated ageing Applicable including laser marked spe

23、cimen Temperature (310 5) C 402 Shrinkage and delamination Applicable Temperature (290 5) C Maximum shrinkage at each end of cable: 0,15 mm2 to 0,60 mm2: 0,80 mm; 1,00 mm2 to 1,20 mm2: 1,00 mm; 2,00 mm2 to 5,00 mm2: 1,20 mm; 9,00 mm2: 1,50 mm; 14,00 mm2: 2,00 mm. 403 Delamination and blocking Applic

24、able Temperature (310 5) C 404 Thermal shock Applicable Temperature (260 5) C and ( 65 2) C Maximum shrinkage at each end of cable: 0,15 mm2 to 0,60 mm2: 0,80 mm; 1,00 mm2 to 1,20 mm2: 1,00 mm; 2,00 mm2 to 5,00 mm2: 1,20 mm; 9,00 mm2: 1,50 mm; 14,00 mm2: 2,00 mm. prEN 2267-010:2015 (E) 6 Table 2 (2

25、of 4) EN 3475- Designation of the test Details 405 Bending at ambient temperature Applicable including laser marked specimen 406 Cold bend test Applicable Temperature ( 65 2) C 407 Flammability Applicable Extinguishing time: 3 s max. 408 Fire resistance Not applicable 409 Air-excluded ageing Not app

26、licable 410 Thermal endurance Applicable 10 000 h at 260 C with curve extrapolation 100 000 h at 200 C with curve reading 411 Resistance to fluids Applicable including laser marked specimens 412 Humidity resistance Applicable Method B Temperature (95 5) C Duration 360 h 413 Wrap back test Applicable

27、 414 Differential scanning calorimeter (DSC test) Applicable (only if PTFE in the construction) 415 Rapid change of temperature Not applicable 416 Thermal stability Not applicable 501 Dynamic cut-through Applicable Temperatures (20 3) C and (260 5) C Nominal section Cut-through force 20 C 260 C mm2

28、N N 0,15 70 15 0,25 85 30 0,40 110 45 0,60 140 55 1,00 140 70 1,20 150 85 2,00 150 95 3,00 165 105 5,00 180 120 9,00 195 135 14,00 210 150 prEN 2267-010:2015 (E) 7 Table 2 (3 of 4) EN 3475- Designation of the test Details 502 Notch propagation Applicable Notch depth: 40 m 503 Scrape abrasion Applica

29、ble Test force on needle for cables: 0,15 mm2 5 N; 0,25 mm2 to 0,60 mm2 8 N; 1,00 mm2 to 1,20 mm2 10 N; 2,00 mm2 to 9,00 mm2 12 N; 14,00 mm2 15 N. 504 Torsion Applicable T3 (260 5) C; T4 (310 5) C 505 Tensile test on conductors and strands Applicable 506 Plating continuity Applicable 507 Adherence o

30、f plating Applicable 508 Plating thickness Applicable 509 Solderability Not applicable 510 Tensile strength and elongation of extruded insulation, sheath and jacket material Not applicable 511 Cable-to-cable abrasion Applicable code 006 0,6 mm2, weight 25 N 2 800 000 cycles 512 Flexure endurance App

31、licable code 006 0,6 mm2, mandrel diameter 15 mm Weight 9 N 1 000 cycles 513 Deformation resistance (Installation with plastic cable ties) Not applicable 601 Smoke density Applicable 602 Toxicity Applicable 603 Resistance to wet arc tracking Applicable code 006 Test voltage 115/200 V AC Wire damage

32、maximum 70 mm 75 % of collateral wires must pass the wet dielectric voltage proof test EN 3475-302. Applicable code 006 Test voltage 230/400 V AC Wire damage maximum 70 mm 604 Resistance to dry arc propagation Applicable Test voltage 115/200 V AC Wire damage maximum 70 mm 75 % of collateral wires mu

33、st pass the wet dielectric voltage proof test EN 3475-302. Applicable Test voltage 230/400 V AC Wire damage maximum 70 mm 605 Wet short circuit test Applicable Test voltage 115/200 V AC and 230/400 V AC Wire damage maximum 70 mm 701 Strippability and adherence of insulation to the conductor Applicab

34、le prEN 2267-010:2015 (E) 8 Table 2 (4 of 4) EN 3475- Designation of the test Details 702 Screen pushback capability Not applicable 703 Permanence of manufacturers marking Applicable 704 Flexibility Applicable code 030 to code 140 Maximum force: 3,00 mm2: 8 N; 5,00 mm2: 9 N; 9 mm2: 10 N; 14 mm2: 11

35、N. 705 Contrast measurement Applicable K 50 % 706 Laser markability Applicable UV laser EN 3838 Subclause 6.2 “Permanence of markings“ Applicable Subclause 6.5 “Exposure to light“ Applicable 6 Quality assurance See EN 9133. 7 Designation 7.1 Identification EXAMPLE Description block CABLE, ELECTRICAL

36、 Identity block EN2267-010A006P Number of this standard Code letter for number of cores (see EN 2267-002) Code for nominal section (see Table 1) Code letter for colour coding of cores (see EN 2267-002) NOTE If necessary, the code I9005 shall be placed between the description block and the identity b

37、lock. prEN 2267-010:2015 (E) 9 7.2 Type code (for short designation) Code designation in accordance with TR 6058, see Table 3. Table 3 EN reference Code designation Single core EN2267-010 DR Single core (Blue UV markable) EN2267-010AxxB DRS 8 Identification and marking See EN 2267-002. 9 Packaging, labelling and delivery lengths See EN 2084. 10 Technical specification See EN 2084.

展开阅读全文
相关资源
  • ASD-STAN PREN 4022-1994 Aerospace Series Pipe Coupling 8 Degrees 30 in Titanium Alloy Elbows 90 Degrees Bulkhead Welded (Edition P1)《航空航天系列 钛合金制830管接头 90焊接穿壁弯头 第P1版[替代 ASD-STAN.pdfASD-STAN PREN 4022-1994 Aerospace Series Pipe Coupling 8 Degrees 30 in Titanium Alloy Elbows 90 Degrees Bulkhead Welded (Edition P1)《航空航天系列 钛合金制830管接头 90焊接穿壁弯头 第P1版[替代 ASD-STAN.pdf
  • ASD-STAN PREN 4021-1994 Aerospace Series Pipe Coupling 8 Degrees 30 in Titanium Alloy Elbows 90 Degrees Bulkhead (Edition P1)《航空航天系列 钛合金制830管接头 90穿壁弯头 第P1版[替代 ASD-STAN PREN 325.pdfASD-STAN PREN 4021-1994 Aerospace Series Pipe Coupling 8 Degrees 30 in Titanium Alloy Elbows 90 Degrees Bulkhead (Edition P1)《航空航天系列 钛合金制830管接头 90穿壁弯头 第P1版[替代 ASD-STAN PREN 325.pdf
  • ASD-STAN PREN 4018-2007 Aerospace series Pipe coupling 8 degree 30 in titanium alloy Elbows 90 degree with thrust wire nut (Edition P2)《航空航天系列 钛合金制830管接头 旋转螺母、带止推金属丝帽的90弯头 第P2版.pdfASD-STAN PREN 4018-2007 Aerospace series Pipe coupling 8 degree 30 in titanium alloy Elbows 90 degree with thrust wire nut (Edition P2)《航空航天系列 钛合金制830管接头 旋转螺母、带止推金属丝帽的90弯头 第P2版.pdf
  • ASD-STAN PREN 3256-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 45 Degree Swivel Nut Welded (Edition P 2 )《航空航天系列 钛合金制830管接头 旋转螺母、焊接式45弯头 第P2版[替代为 AS.pdfASD-STAN PREN 3256-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 45 Degree Swivel Nut Welded (Edition P 2 )《航空航天系列 钛合金制830管接头 旋转螺母、焊接式45弯头 第P2版[替代为 AS.pdf
  • ASD-STAN PREN 3254-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 90 Degree Bulkhead Welded (Edition P 2)《航空航天系列 钛合金制830管接头 焊接式穿壁90弯头 第P2版[替代为 ASD-STAN.pdfASD-STAN PREN 3254-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 90 Degree Bulkhead Welded (Edition P 2)《航空航天系列 钛合金制830管接头 焊接式穿壁90弯头 第P2版[替代为 ASD-STAN.pdf
  • ASD-STAN PREN 3253-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 90 Degree Bulkhead (Edition P 2 )《航空航天系列 钛合金制830管接头 穿壁90弯头 第P2版[替代为 ASD-STAN PREN 402.pdfASD-STAN PREN 3253-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 90 Degree Bulkhead (Edition P 2 )《航空航天系列 钛合金制830管接头 穿壁90弯头 第P2版[替代为 ASD-STAN PREN 402.pdf
  • ASD-STAN TR AMS2750-2009 《航空航天系列 航空航天材料规范 高温测定法》.pdfASD-STAN TR AMS2750-2009 《航空航天系列 航空航天材料规范 高温测定法》.pdf
  • ASD-STAN TR AMS2750 FRENCH-2009 《航空航天系列 航空航天材料规范 高温测定法》.pdfASD-STAN TR AMS2750 FRENCH-2009 《航空航天系列 航空航天材料规范 高温测定法》.pdf
  • ASD-STAN TR 9536-2008 Aerospace series Declarable Substances Recommended Practice《航空航天系列 需申报物质 建议做法》.pdfASD-STAN TR 9536-2008 Aerospace series Declarable Substances Recommended Practice《航空航天系列 需申报物质 建议做法》.pdf
  • ASD-STAN TR 9535-2008 Aerospace series Substance declaration (Edition 1)《航空航天系列 物质声明 第1版》.pdfASD-STAN TR 9535-2008 Aerospace series Substance declaration (Edition 1)《航空航天系列 物质声明 第1版》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASD

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1