ASTM F2371-2010 Standard Test Method for Measuring the Heat Removal Rate of Personal Cooling Systems Using a Sweating Heated Manikin《使用一个焊接加热人体模型测量个人冷却系统的除热率的标准试验方法》.pdf

上传人:explodesoak291 文档编号:538524 上传时间:2018-12-07 格式:PDF 页数:4 大小:76.08KB
下载 相关 举报
ASTM F2371-2010 Standard Test Method for Measuring the Heat Removal Rate of Personal Cooling Systems Using a Sweating Heated Manikin《使用一个焊接加热人体模型测量个人冷却系统的除热率的标准试验方法》.pdf_第1页
第1页 / 共4页
ASTM F2371-2010 Standard Test Method for Measuring the Heat Removal Rate of Personal Cooling Systems Using a Sweating Heated Manikin《使用一个焊接加热人体模型测量个人冷却系统的除热率的标准试验方法》.pdf_第2页
第2页 / 共4页
ASTM F2371-2010 Standard Test Method for Measuring the Heat Removal Rate of Personal Cooling Systems Using a Sweating Heated Manikin《使用一个焊接加热人体模型测量个人冷却系统的除热率的标准试验方法》.pdf_第3页
第3页 / 共4页
ASTM F2371-2010 Standard Test Method for Measuring the Heat Removal Rate of Personal Cooling Systems Using a Sweating Heated Manikin《使用一个焊接加热人体模型测量个人冷却系统的除热率的标准试验方法》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F2371 10Standard Test Method forMeasuring the Heat Removal Rate of Personal CoolingSystems Using a Sweating Heated Manikin1This standard is issued under the fixed designation F2371; the number immediately following the designation indicates the year oforiginal adoption or, in the case o

2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONPersonal Cooling Systems (PCS) are used when wearers could be exposed to conditions that rende

3、rthe bodys thermoregulatory system inadequate to maintain body core temperature within a safe range.The use of PCS can reduce the possibility of heat stress related physiological disorders and can alsoprovide increased comfort, which in turn could also result in higher productivity. Cooling needs va

4、rygreatly depending on the level of activity, the external temperature and humidity, as well as thepersonal protective equipment worn. The PCS should be selected that is best suited for the specificapplication. Sweating heated manikins provide a convenient tool to assess the effectiveness of PCS ast

5、hey can provide objective and repeatable results. These instruments can be used to quantify, in areproducible manner, the cooling rate and cooling duration provided by the PCS while eliminating thevariables associated with human physiology. Sweating heated manikins can be used for directcomparisons

6、of PCS.1. Scope1.1 This test method covers the measurement of heat re-moval rate from a sweating heated manikin as well as theduration of cooling provided by a cooling garment, in order toassess the effectiveness of PCS.21.1.1 This test method requires the use of a sweating heatedmanikin. The sweati

7、ng capability is essential, to take intoaccount the potentially large fraction of heat dissipation asso-ciated with evaporative cooling.1.2 The experimental values obtained for the cooling ratesand cooling duration apply only to the particular PCS andadditional clothing ensemble (standard outer garm

8、ent, outergarment integrated to the PCS, or any other outer garment, asappropriate) as tested, and for the specified environmentalconditions.1.3 The values stated in this standard shall be SI units.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its u

9、se. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3F1291 Test Method for Measuring the Thermal Insulationof Clothing Using a

10、Heated ManikinF1494 Terminology Relating to Protective ClothingF2370 Test Method for Measuring the Evaporative Resis-tance of Clothing Using a Sweating Manikin3. Terminology3.1 Definitions of Terms Specific to This Standard:3.2 clo, nunit of thermal resistance defined as the insula-tion required to

11、keep a resting man (producing heat at the rateof 58 W/m2) comfortable in an environment at 21C, airvelocity 0.1 m/s, or roughly the insulation value of typicalindoor clothing.3.2.1 DiscussionNumerically, the clo is equal to 0.155Km2/W.3.3 clothing ensemble, na group of garments worn to-gether on the

12、 body at the same time.3.4 garment, na single item of clothing (for example,shirt).1This test method is under the jurisdiction ofASTM Committee F23 on PersonalProtective Clothing and Equipment and is the direct responsibility of SubcommitteeF23.60 on Human Factors.Current edition approved Jan. 1, 20

13、10. Published January 2010. Originallyapproved in 2005. Last previous edition approved in 2005 as F2371 - 05. DOI:10.1520/F2371-05.2The present standard does not attempt to determine the thermal insulation andevaporative resistance of garments worn with the PCS, or these same properties forthe PCSs

14、themselves. Test Methods F1291 and F2370 are available for thesemeasurements.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page ont

15、he ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.5 thermal insulation, nthe resistance to dry heat transferby way of conduction, convection, and radiation.3.6 total heat loss, nthe amount of heat transferredthrough a

16、 clothing system by the combined dry and evaporativeheat exchanges under specified conditions expressed in wattsper square metre.3.7 For definitions of terms related to protective clothingused in this test method, refer to Terminology F1494.4. Significance and Use4.1 This test method can be used to

17、quantify and comparethe cooling provided by different Personal Cooling Systems(PCSs) worn with a standard outer garment or with any otherspecified one.4.1.1 The test method is intended to allow garments basedon various cooling technologies to be evaluated fairly andobjectively, by taking into accoun

18、t convective and evaporativeheat transfer.4.1.2 A sweating thermal manikin accurately accounts forevaporative cooling, which represents the only active means ofheat transfer occurring in humans. Utilizing a sweating thermalmanikin will also permit the heat removal rate to be measuredfor all types of

19、 PCS.4.2 The measurements of heat removal rates and duration ofcooling provided by the PCSs depend on the apparatus andtechniques used.4.2.1 It is not practical in a test method of this scope toestablish details sufficient to cover all contingencies.4.2.2 Departures from the instructions in this tes

20、t methodwill potentially lead to significantly different test results.4.2.3 Technical knowledge concerning the theory of heattransfer, temperature, air motion measurement, evaporativecooling, and testing practices is needed to evaluate whichdepartures from the instructions given in this test method

21、aresignificant. Report any departures with the results.5. Apparatus5.1 ManikinA standing sweating manikin having theform, shape, and size of an adult male or female shall be used.The manikin shall be heated to a uniform, constant, skintemperature.5.1.1 Size and ShapeThe manikin shall be constructed

22、tosimulate the body of a human being; that is, it shall consist ofa head, chest/back, abdomen, buttocks, arms, hands (preferablywith fingers extended to allow gloves to be worn), legs, andfeet. Total surface area shall be 1.8 6 0.3 m2, and height shallbe 170 6 10 cm. The manikins dimensions shall co

23、rrespond tothose required for standard sizes of garments because devia-tions in fit will significantly affect the results.5.1.2 Sweat GenerationThe manikin must have the abilityto evaporate water from its surface. Some examples of asweating system include a cotton body suit saturated withwater or wa

24、ter fed capillary body suit worn over a thermalmanikin. Other technologies exist that deliver water to themanikins surface with a valve delivery system.5.1.2.1 Sweating Surface AreaThe surface area fromwhich water is evaporated must include the chest, back,abdomen, buttocks, arms and legs. Ideally,

25、the manikins head,hands, and feet should be sweating also.5.1.3 Surface TemperatureThe manikin shall be con-structed so as to maintain a constant uniform temperature overthe nude body surface, with no local hot or cold spots. The skintemperature of the manikin shall be 35C. Local deviationsfrom the

26、mean skin temperature shall not exceed 60.3C.Temperature uniformity of the nude manikin shall be evaluatedat least once annually using an infrared thermal imagingsystem or equivalent method. Repeat this procedure afterrepairs or alterations are completed that could affect tempera-ture uniformity (fo

27、r example, replacement of a heating ele-ment).5.2 Power-Measuring InstrumentsRecord the time his-tory of the power input to the manikin over the entire testperiod. Overall accuracy of the power monitoring equipmentmust be within 62 % of the reading for the average power forthe test period. Since the

28、re are a variety of devices andtechniques used for power measurement, no specified calibra-tion procedures shall be given. However, an appropriate powercalibration procedure is to be developed and documented.5.3 Equipment for Measuring the Manikins SkinTemperatureMeasure the mean skin temperature wi

29、th pointsensors or distributed temperature sensors.5.3.1 Point SensorsPoint sensors may be thermocouples,resistance temperature devices (RTDs), thermistors, or equiva-lent sensors. They shall be no more than 2.0 mm thick and shallbe well bonded, both mechanically and thermally, to themanikins surfac

30、e. Lead wires shall be bonded to the surface orpass through the interior of the manikin, or both. The sensorsshall be distributed so that each one represents the same surfacearea or are area-weighted when calculating the mean skintemperature for the body. A minimum of 15 point sensors arerequired. A

31、t least one sensor shall be placed on the head, chest,back, abdomen, buttocks, and both the right and left upper arm,lower arm, hand, thigh, calf, and foot. These sensors must beplaced in the same position for each test and the placement ofthe sensors shall be given in the report.5.3.2 Distributed S

32、ensorsIf distributed sensors are used(for example, resistance wire), then the sensors must bedistributed over the surface so that all areas are equallyweighted. If several such sensors are used to measure thetemperature of different parts of the body, then their respectivetemperatures should be area

33、-weighted when calculating themean skin temperature. Distributed sensors must be small indiameter (that is, less than 1.0 mm) and firmly bonded to themanikin surface at all points.5.4 Controlled Environmental ChamberThe manikinshall be placed in a chamber at least 2 by 2 by2mindimensionthat can prov

34、ide uniform conditions, both spatially and tempo-rally.5.4.1 Spatial VariationsSpatial variations shall not exceedthe following: air temperature 61.0C, relative humidity65 %, and air velocity 650 % of the mean value. In addition,the mean radiant temperature shall not be more than 1.0Cdifferent from

35、the mean air temperature. The spatial uniformityshall be verified at least annually or after any significantmodifications are made to the chamber. Spatial uniformity shallbe verified by recording values for the conditions stated aboveat heights of 0.1, 0.6, 1.1, 1.4, and 1.7 m above the floor at the

36、F2371 102location occupied by the manikin. Sensing devices specifiedbelow shall be used when measuring the environmental con-ditions.5.4.2 Temporal VariationsTemporal variations shall notexceed the following: air temperature 60.5C, mean radianttemperature 60.5C, relative humidity 65 %, air velocity6

37、20 % of the mean value for data averaged over 5 minutes.(See 5.4.5).5.4.3 Relative Humidity Measuring EquipmentAnyhumidity-sensing device with an accuracy of 65 % relativehumidity and a repeatability of 63 % is acceptable (forexample, wet bulb/dry bulb, dew point hygrometer). Only onelocation needs

38、to be monitored during a test to ensure that thetemporal uniformity requirements are met.5.4.4 Air Temperature SensorsShielded air temperaturesensors shall be used. Any sensor with an overall accuracy of60.15C is acceptable (for example, RTD, thermocouple,thermistor). The sensor shall have a time co

39、nstant not exceed-ing 1 minute. The sensor(s) shall be 0.5 m in front of themanikin. If a single sensor is used it shall be 1.0 m above thefloor. If multiple sensors are used, they shall be spaced at equalheight intervals and their readings averaged.5.4.5 Air Velocity IndicatorAn omni-directional an

40、emom-eter with 60.05 m/s accuracy shall be used. Average measure-ments for a minimum of at least 1 min at each location. If it isdemonstrated that velocity does not vary temporally by morethan 60.05 m/s, then it is not necessary to monitor air velocityduring a test. The value of the mean air velocit

41、y must bereported, however. If air velocity is monitored, then measure-ment location requirements are the same as for temperature.5.5 CalibrationCalibrate the sweating heated manikin inaccordance with Test Method F2370.6. Sampling, Test Specimens, and Test Units6.1 Personal Cooling SystemIt is suffi

42、cient to test onlyone sample personal cooling system, with replicate measure-ments made on that single sample.6.1.1 Size and FitSelect the size of the PCS garment thatbest fits the manikin. Base fit on the manufacturers designedspecifications for fitting the garment to an actual human body.It is exp

43、ected that certain PCS ensembles will not fit properlydue to the rigidity and set position of sweating thermalmanikins. State the size of each PCS used and any fitdiscrepancies in the report.6.2 Specimen PreparationTest the PCS in the as-receivedcondition or after dry cleaning or laundering in accor

44、dancewith the manufacturers instructions.7. Procedure7.1 Environmental Test ConditionsThe following isother-mal conditions shall be considered standard.7.1.1 Air VelocityThe air velocity shall be 0.4 6 0.1 m/sor less during a test (that is, still air conditions).7.1.2 Relative HumidityThe relative h

45、umidity shall be 406 5 % during a test.7.1.3 Air TemperatureThe air temperature shall be 35 60.5C during a test.7.2 Mean Skin Temperature of ManikinThe manikinsoutermost sweating surface temperature shall be 35 6 0.5Cfor all tests. The mean skin temperature shall not be allowed todrift more than 60.

46、1C during a 2-hour test.7.3 SweatingThe manikin surface must have water avail-able for evaporation throughout the test period. The amount ofwater on the surface should be the supplied or added to thesurface of the manikin in the same manner as was used togenerate the evaporative resistance value dur

47、ing calibration(see 5.5).7.3.1 Manikins without sweating heads, hands or feet can-not be used to evaluate PCS that provide cooling to these areas.These manikins can only evaluate PCS that provide cooling tothe arms, legs, torso chest and back.7.3.2 Areas that do not have a sweating surface must behe

48、ated to properly simulate heat production in a human body.7.4 Saturate the manikins sweating surface with water.Water added to the manikins sweating surface must be heatedto 35 6 0.5C before being delivered to the manikin.7.4.1 DiscussionSaturation can usually be detected visu-ally however, if neede

49、d an IR camera can insure that thesurface is completely saturated.7.5 Baseline TestFirst, carry out a baseline test withoutcooling. Perform this test with the PCS ensemble placed on themanikin, but turned off, if possible, so that no cooling isprovided. In the case where the PCS cannot be turned off (forexample, ice vest, or phase change material), carry out thebaseline test with the PCS in equilibrium with the atmospherein the test chamber by previously conditioning it in thechamber for at least 12 hours.7.5.1 Dress the sta