1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58frequency range 3 kHz to 148,5 kHz and 1,6 MHz to 30 MHz Part 4-2: Low voltage decoupling filters S
2、afety requirementsThe European Standard EN 50065-4-2:2001, with the incorporation of amendments A1:2003 and A2:2005, has the status of a British StandardICS 31.160; 33.040.30Signalling on low voltage electrical installations in the BRITISH STANDARDBS EN 50065-4-2:2002Incorporating Amendment Nos. 1 a
3、nd 2BS EN 50065-4-2:2002This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 24 January 2002 BSI 12 December 2005ISBN 0 580 38881 6A list of or
4、ganizations represented on this committee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Corres
5、pondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard does not of
6、itself confer immunity from legal obligations.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 31 and a back cover.The BSI copyright date displayed in this document indicates when the document was last issued.Amendments issued since publicat
7、ionAmd. No. Date Comments14440 29 May 2003 See national foreword15775 12 December 2005 Change to title and see national foreword aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep th
8、e UK interests informed; monitor related international and European developments and promulgate them in the UK.National forewordThis British Standard is the official English language version of EN 50065-4-2:2001, including amendments A1:2003 and A2:2005.The start and finish of text introduced or alt
9、ered by amendment is indicated in the text by tags !“. Tags indicating changes to CENELEC text carry the number of the CENELEC amendment. For example, text altered by CENELEC amendment 1 is indicated by !“.The UK participation in its preparation was entrusted to Technical Committee PEL/205, Mains si
10、gnalling, which has the responsibility to: EUROPEAN STANDARD EN 50065-4-2 +A2 NORME EUROPENNE August 2001 April 2005 EUROPISCHE NORM +A1 January 2003 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnisc
11、he Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50065-4-2:2001 + A1:2003 + A2:2005 E ICS 31.160; 33.040.30 English version Signalling on low voltage electr
12、ical installations in the frequency range 3 kHz to 148,5 kHz and 1,6 MHz to 30 MHz Part 4-2: Low voltage decoupling filters - Safety requirements (includes amendments A1:2003 and A2:2005) Transmission de signaux sur les rseaux lectriques basse tension dans la bande de frquences de 3 kHz 148,5 kHz Pa
13、rtie 4-2: Filtres basse tension de dcouplage - Exigences de scurit (inclut les amendements A1:2003 et A2:2005) Signalbertragung auf elektrischen Niederspannungsnetzen im Frequenzbereich 3 kHz bis 148,5 kHz Teil 4-2: Niederspannungs-Entkopplungsfilter Sicherheitsanforderungen (enthlt nderungen A1:200
14、3 und A2:2005) This European Standard was approved by CENELEC on 2000-11-01. Amendment A1 was approved by CENELEC on 2002-12-01 and amendment A2 was approved by CENELEC on 2005-3-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for givi
15、ng this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official v
16、ersions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees
17、 of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 50065-4-2:2001 - 2 -
18、Foreword This European Standard was prepared by SC 205A, Mains communicating systems, of Technical Committee CENELEC TC 205, Home and Building Electronic Systems (HBES). This European Standard has been prepared under a mandate given to CENELEC by the European Commission and covers the essential requ
19、irements of the Low Voltage Directive 73/23/EEC. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50065-4-2 on 2000-11-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an
20、identical national standard or by endorsement (dop) 2002-02-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2003-11-01 EN 50065 consists of the following parts, under the general title: Signalling on low voltage electrical installations in the freque
21、ncy range 3 kHz to 148,5 kHz Part 1 General requirements, frequency bands and electromagnetic disturbances Part 2-1 Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light
22、 industrial environments Part 2-2 Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments Part 2-3 Immunity requirements for mains communications equipment and systems operating in
23、the range of frequencies 3 kHz to 95 kHz and intended for use by electricity suppliers and distributors Part 4-1 Low voltage decoupling filters Generic specification Part 4-2 Low voltage decoupling filters Safety requirements Part 4-3 Low voltage decoupling filters Incoming filter Part 4-4 Low volta
24、ge decoupling filters Impedance filter Part 4-5 Low voltage decoupling filters Segmentation filter Part 4-6 Low voltage decoupling filters Phase coupler Part 7 Equipment impedance #This safety standard EN 50065-4-2 has no frequency dependent content. It was originally conceived as a safety document
25、within the EN 50065 set of standards, which have a frequency of 3 kHz to 148,5 kHz. When the scope of SC 205A was extended to 30 MHz, SC 205A agreed that the scope of the published safety standard, Part 4-2 “Low voltage decoupling filters Safety requirements“ should be amended to include the band 1,
26、6 MHz to 30 MHz in order to cover the additional set of standards for 1,6 MHz to 30 MHz. This required no technical changes to the body of the document. In addition, it was agreed that Part 4-7 “Portable low voltage decoupling filters Safety requirements“ should also cover both frequency ranges. For
27、 this reason the title of this part of EN 50065 covers the extended frequency ranges 3 kHz to 148,5 kHz and 1,6 MHz to 30 MHz.$ - 3 - EN 50065-4-2:2001 Foreword to amendment A1 This amendment was prepared by SC 205A, Mains communicating systems, of Technical Committee CENELEC TC 205, Home and Buildi
28、ng Electronic Systems (HBES). The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment A1 to EN 50065-4-2:2001 on 2002-12-01. The following dates were fixed: latest date by which the amendment has to be implemented at national level by publicati
29、on of an identical national standard or by endorsement (dop) 2003-12-01 latest date by which the national standards conflicting with the amendment have to be withdrawn (dow) 2005-12-01 Foreword to amendment A2 This amendment to the European Standard EN 50065-4-2:2001 was prepared by SC 205A, Mains c
30、ommunicating systems, of Technical Committee CENELEC TC 205, Home and Building Electronic Systems (HBES). The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment A2 to EN 50065-4-2:2001 on 2005-03-01. The following dates were fixed: latest date
31、 by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2006-03-01 latest date by which the national standards conflicting with the amendment have to be withdrawn (dow) 2008-03-01 EN 50065-4-2:2001 - 4 - Contents 1 Scop
32、e.5 2 Normative references.5 3 Definitions.6 4 General requirements 7 5 General notes on tests.7 6 Rating 7 7 Classification 8 8 Marking8 9 Dimensions 10 10 Protection against electric shock 10 11 Provision for protective earthing. 11 12 Terminals 12 13 Construction 13 14 Resistance to ageing, to ha
33、rmful ingress of water and to humidity 14 15 Insulation resistance and dielectric strength. 17 16 Temperature rise . 18 17 Mechanical strength 20 18 Resistance to heat. 21 19 Screws, current-carrying parts and connections 22 20 Creepage distances, clearances and distances through sealing compound. 2
34、3 21 Resistance to abnormal heat, to fire and to tracking 26 22 Resistance to rusting 27 23 Components. 27 24 Abnormal conditions 28 25 Protection against short-circuit. 30 26 Resistance to transients. 31 Tables Table 1 Symbols for identification of the termination . 9 Table 2 Connectable cross-sect
35、ions of copper conductors. 13 Table 3 Test current 19 Table 4 Permissible temperature rise 19 Table 5 Related torque 20 Table 6 Creepage distances and clearances 24 Table 7 Creepage distances for printed circuit board . 24 Table 8 Minimum clearances for printed circuit board 25 - 5 - EN 50065-4-2:20
36、01 1 Scope This product safety standard applies to electrical equipment, such as decoupling filters and phase couplers in a mains communication system for a phase to neutral voltage not exceeding AC 250 V and a nominal current not exceeding 125 A, intended for household and similar fixed-electrical
37、installations including residential, commercial and light industrial buildings 2 Normative references This European Standard incorporated by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications
38、 are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For updated references the latest edition of the publication referred to applies. EN 60065 Audio, vid
39、eo and similar electronic apparatus Safety requirements (IEC 60065) EN 60068-2-75 1997 Environmental testing Part 2-75: Tests Test Eh Hammer tests (IEC 60068-2-75:1997) EN 60127 series Miniature fuses (IEC 60127 series) EN 60417 series Graphical symbols for use on equipment (IEC 60417 series) EN 605
40、29 Degrees of protection provided by enclosures (IP code) (IEC 60529) EN 60669-1 1999 Switches for household and similar fixed electrical installations Part 1: General requirements (IEC 60669-1:1998, mod.) EN 60695-2-1/X 1996 Fire hazard testing- Part 2: Test methods (IEC 60695-2-1/X:1994) EN 60721-
41、3-3 1995 Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Section 3: Stationary use at weather protected locations (IEC 60721-3-3:1994) EN 60999-1 2000 Connecting devices Safety requirements for screw-type and screwless-type
42、 clamping units for electrical copper conductors Part 1: General requirements and particular requirements for conductors from 0,5 mm2up to 35 mm2(included) (IEC 60999-1:1999) EN 132400 1994 Sectional Specification: Fixed capacitors for electromagnetic interference suppression and connection to the s
43、upply mains (Assessment level D) HD 214 S2 1980 Method of determining the comparative and the proof tracking indices of solid insulating materials under moist conditions (IEC 60112:1979) HD 384.4.442 S1 1997 Electrical installations of buildings Part 4: Protection for safety Chapter 44 Protection ag
44、ainst overvoltages - Section 442: Protection of low-voltage installations against faults between high-voltage systems and earth (related to IEC 60364-4-442:1993 + A1:1995) HD 625.1 S1 1996 Insulation coordination for equipment within low-voltage systems Part 1: Principles, requirements and tests (IE
45、C 60664-1:1992, mod.) IEC 6069510-2 1995 Fire hazard testing Part 10: Guidance and test methods for the minimisation of the effects of abnormal heat on electrotechnical products involved in fires Section 2 Method for testing products made from non-metallic materials for resistance to heat using the
46、ball pressure test EN 50065-4-2:2001 - 6 - IEC 60999-2 1995 Connecting devices Safety requirements for screw-type and screw-less clamping units for electrical copper conductors Part 2: Particular requirements for conductors from 35 mm2up to 300 mm2 3 Definitions Where the terms voltage and current a
47、re used, they imply r.m.s. values, unless otherwise specified. For the purpose of this standard, the following definitions apply: 3.1 decoupling filter a device which attenuates incoming or outgoing signals within a specified frequency range 3.2 phase coupler a device which transmits a signal within
48、 a specified frequency range from one phase to another in a multi-phase installation 3.3 fault conditions abnormal conditions which may occur during normal operation 3.4 enclosed equipment equipment which is mounted and/or applied without an additional enclosure 3.5 unenclosed equipment equipment in
49、tended to be built into an enclosure which completely covers the equipment 3.6 partly enclosed equipment equipment intended to be built into an appropriate enclosure which only covers the unenclosed part of the equipment NOTE Flush-mounted equipment intended to be located in a box is an example of such equipment. 3.7 terminal the conductive part of one pole, composed of one or more clamping unit(s) and insulation if necessary 3.8 screw-type terminal a clamping