BS ISO 7789-2008 Hydraulic fluid power Two- three- and four-port screw-in cartridge valves Cavities《液压传动 二通、三通和四通螺纹式插装阀 插装孔》.pdf

上传人:outsidejudge265 文档编号:588053 上传时间:2018-12-15 格式:PDF 页数:34 大小:901.43KB
下载 相关 举报
BS ISO 7789-2008 Hydraulic fluid power Two- three- and four-port screw-in cartridge valves Cavities《液压传动 二通、三通和四通螺纹式插装阀 插装孔》.pdf_第1页
第1页 / 共34页
BS ISO 7789-2008 Hydraulic fluid power Two- three- and four-port screw-in cartridge valves Cavities《液压传动 二通、三通和四通螺纹式插装阀 插装孔》.pdf_第2页
第2页 / 共34页
BS ISO 7789-2008 Hydraulic fluid power Two- three- and four-port screw-in cartridge valves Cavities《液压传动 二通、三通和四通螺纹式插装阀 插装孔》.pdf_第3页
第3页 / 共34页
BS ISO 7789-2008 Hydraulic fluid power Two- three- and four-port screw-in cartridge valves Cavities《液压传动 二通、三通和四通螺纹式插装阀 插装孔》.pdf_第4页
第4页 / 共34页
BS ISO 7789-2008 Hydraulic fluid power Two- three- and four-port screw-in cartridge valves Cavities《液压传动 二通、三通和四通螺纹式插装阀 插装孔》.pdf_第5页
第5页 / 共34页
亲,该文档总共34页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARDBS ISO 7789:2007Hydraulic fluid power Two-, three- and four-port screw-in cartridge valves CavitiesICS 23.100.50g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g

2、60g53g44g42g43g55g3g47g36g58BS ISO 7789:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2008 BSI 2008ISBN 978 0 580 55037 9National forewordThis British Standard is the UK implementation of ISO 7789:2007. It supersedes BS ISO 7

3、789:1998 which is withdrawn. The UK participation in its preparation was entrusted by Technical Committee MCE/18, Fluid power systems and components, to Panel MCE/18/-/5, Control components.A list of organizations represented on this committee can be obtained on request to its secretary.This publica

4、tion does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments/corrigenda issued since publicationDate CommentsReference numberISO 7789:2007(E)I

5、NTERNATIONAL STANDARD ISO7789Second edition2007-10-01Hydraulic fluid power Two-, three- and four-port screw-in cartridge valves Cavities BS ISO 7789:2007ii iiiContents Page Foreword iv Introduction v 1 Scope . 1 2 Normative references . 1 3 Terms, definitions and symbols 2 4 Dimensions 2 5 Tolerance

6、s . 2 6 Ports usage and identification 3 7 Identification statement (Reference to this International Standard) 3 Bibliography . 24 BS ISO 7789:2007iv Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work

7、 of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmen

8、tal, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The ma

9、in task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. At

10、tention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 7789 was prepared by Technical Committee ISO/TC 131, Fluid power systems, Subcommittee SC 5, Contro

11、l products and components. This second edition cancels and replaces the first edition (ISO 7789:1998), which has been technically revised. It also incorporates the Technical Corrigendum ISO 7789:1998/Cor.1:1999. BS ISO 7789:2007vIntroduction In hydraulic fluid power systems, power is transmitted and

12、 controlled through a liquid under pressure within an enclosed circuit. Typical components found in such systems include hydraulic valves. These devices control flow direction, pressure or flow rate liquids in the enclosed circuit. BS ISO 7789:2007blank1Hydraulic fluid power Two-, three- and four-po

13、rt screw-in cartridge valves Cavities 1 Scope This International Standard specifies the dimensions and provides other data relating to cavities in which two-, three- and four-port, screw-in cartridge valves are mounted in order to ensure interchangeability. It is applicable to two-, three- and four-

14、port screw-in cartridge valves generally used in industrial and mobile equipment. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the

15、referenced document (including any amendments) applies. ISO 1101:2004, Geometrical Product Specifications (GPS) Geometrical tolerancing Tolerances of form, orientation, location and run-out ISO 1219-1:2006, Fluid power systems and components Graphic symbols and circuit diagrams Part 1: Graphic symbo

16、ls for conventional use and data-processing applications ISO 1302:2002, Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation ISO 2768-1:1989, General tolerances Part 1: Tolerances for linear and angular dimensions without individual tolerance indi

17、cations ISO 2768-2:1989, General tolerances Part 2: Geometrical tolerances for features without individual tolerance indications ISO 5598:1), Fluid power systems and components Vocabulary ISO 5783:1995, Hydraulic fluid power Code for identification of valve mounting surfaces and cartridge valve cavi

18、ties ISO 6149-1:2006, Connections for hydraulic fluid power and general use Ports and stud ends with ISO 261 metric threads and O-ring sealing Part 1: Ports with truncated housing for O-ring seal ISO 16874:2004, Hydraulic fluid power Identification of manifold assemblies and their components 1) To b

19、e published. (Revision of ISO 5598:1985) BS ISO 7789:20072 3 Terms, definitions and symbols For the purposes of this document, the terms and definitions given in ISO 5598 and the graphical symbols given in ISO 1219-1 apply. 4 Dimensions 4.1 The dimensions of cavities for hydraulic screw-in cartridge

20、 valves with two-, three- and four-ports shall be selected from the figures and tables specified in 4.2 to 4.10. 4.2 The dimensions of cavities for two-port valves (excluding pressure-relief valves) with 5 mm to 20,5 mm maximum port diameter are shown in Figure 1 and given in Table 1. 4.3 The dimens

21、ions of cavities for two-port pressure-relief valves with 5 mm to 20,5 mm maximum port diameter and with a flow direction from port 1 to port 2, are shown in Figure 2 and given in Table 3. 4.4 The dimensions of cavities for two-port pressure-relief valves with 6 mm to 20,5 mm maximum port diameter a

22、nd with a flow direction from port 2 to port 1, are shown in Figure 3 and given in Table 5. 4.5 The dimensions of cavities for three-port valves with 6 mm to 20,5 mm maximum port diameter are shown in Figure 4 and given in Table 7. 4.6 The dimensions of cavities for four-port valves with 6 mm to 20,

23、5 mm maximum port diameter are shown in Figure 5 and given in Table 9. 4.7 The dimensions of cavities for two-port valves (excluding pressure-relief valves) with 10,5 mm to 20,5 mm maximum main port diameter and one pilot port are shown in Figure 6 and given in Table 11. 4.8 The dimensions of caviti

24、es for two-port pressure-relief valves with 10,5 mm to 20,5 mm maximum main port diameter, one vent or pilot port and with a flow direction from port 1 to port 2 are shown in Figure 7 and given in Table 13. 4.9 The dimensions of cavities for two-port pressure-relief valves with 10,5 mm to 20,5 mm ma

25、ximum main port diameter, one vent or pilot port and with a flow direction from port 2 to port 1 are shown in Figure 8 and given in Table 15. 4.10 The dimensions of cavities for three-port valves with 10,5 mm to 20,5 mm maximum main port diameter and one pilot port are shown in Figure 9 and given in

26、 Table 17. 5 Tolerances Tolerances values for all dimensions and surface roughness are given in Figures 1 to 9 and in Tables 1, 3, 5, 7, 9, 11, 13, 15 and 17, in accordance with ISO 1101 and ISO 1302. Tolerances for linear and angular dimensions shall be in accordance with the designation as describ

27、ed in ISO 2768-1. Geometrical tolerances shall be in accordance with the designation as described in ISO 2768-2. NOTE All figures in this International Standard indicate tolerance requirements using the ISO code “ISO 2768-mk” as described in ISO 2768-1 and ISO 2768-2. BS ISO 7789:200736 Ports usage

28、and identification 6.1 Interchangeability of cartridge valves in the cavities defined by this International Standard requires uniform identifications and functions of the valve ports. Symbols for the valve types intended for use in each cavity are shown in Tables 2, 4, 6, 8, 10, 12, 14, 16 and 18. P

29、ort usage and identification (1, 2, 3 and 4) are shown on the symbols. 6.2 The tabulated symbols illustrate general types of valves. Variations within each type shall conform to the port usage convention shown for that type. 6.3 Some of the tabulated symbols are commonly combined with other graphic

30、elements to represent a complete valve. For example, the four-port directional control valve shown in Table 10 normally includes operators such as solenoids or springs. Interchangeability of such complete valves requires that the combined symbols, including the added elements, be identical as to por

31、t connection in each operator condition. 6.4 The manifold identification shall be in accordance with ISO 16874. 7 Identification statement (Reference to this International Standard) It is strongly recommended to manufacturers who choose to conform to this International Standard that the following st

32、atement be used in test reports, catalogues and sales literature: “Cavity dimensions and port usage are in accordance with ISO 7789:2007, Hydraulic fluid power Two-, three- and four-port screw-in cartridge valves Cavities.” BS ISO 7789:20074 Key 1, 2, ports NOTE The same designations are used in Tab

33、le 2. PD (thread) pitch diameter VE visual examination aThe dimensions given are the minimum space required for a screw-in cartridge valve with an allowance for using an axially fitting tool, such as a box spanner, to tighten the cartridge; if it is necessary to use a flat spanner, then adequate cle

34、arance should be provided. This is also the minimum recommended distance between centres of two similarly sized cavities. Connectors on electrically operated valves may exceed this space dimension and allowance shall be made for fitting and removing any such connectors. bNo burrs permitted in this a

35、rea, the edge must be rounded. The cavity geometry is normally produced with an appropriate multi-diameter form tool. Sharp edges should be avoided by rounding to a radius of 0,1 mm to 0,2 mm. cRadial groove optional. dDatum area inside ring nose. eThe port is in accordance with ISO 6149-1. Figure 1

36、 Cavities for two-port valves (excluding pressure-relief valves) with 5 mm to 20,5 mm maximum port diameter BS ISO 7789:20075Table 1 Dimensions for cavities for two-port valves (excluding pressure-relief valves) with 5 mm to 20,5 mm maximum port diameter Dimensions in millimetres Dimension by codifi

37、cationaParameter 18-01-0-07 20-01-0-07 22-01-0-07 27-01-0-07 33-01-0-07 42-01-0-07 ThreadbM181,5 M201,5 M221,5 M272 M332 M422 D1min. 32 38 42 48 58 74 D2H8 15 17 19 23 29 38 D315 17 19 23 29 38 T1min. 14,5 14,5 15,5 19 19 19,5 T2min. 14,5 14,5 17 22 22 23 T3max. 19,5 20,5 27,5 35 38,5 43,5 (T4) 20 2

38、1 28 35,5 39 44 0,45 0T+21,3 22,3 29,3 37,2 40,7 45,7 T6min.c29,5 30,5 38,5 46,5 50 56 T6160T+d31 32 40 48 52 58 aCodification is in accordance with ISO 5783. bThe port is in accordance with ISO 6149-1 (relevant for dimensions and tolerances not specified in this International Standard). cThis dimen

39、sion is the minimum finished length required for the sealing diameter on the cartridge. dSuggested pre-machining depth to obtain appropriate diameter tolerance for T6. For some valve types, additional pilot drill dimensions may be specified by the valve manufacturer to provide clearance for an exten

40、sion to the valve and/or to allow for minimum fluid flow path in this area. Table 2 Symbols for valves entering the cavities shown in Figure 1 Description Symbol Description Symbol Non-return valve Throttle non-return valve Flow-control valve with free-flow return check Pressure-compensated flow-con

41、trol valve Pressure-compensated flow control valve with free-flow return check Two-port directional control valve Two-port directional control poppet (seat) valve BS ISO 7789:20076 Key 1, 2, ports NOTE The same designations are used in Table 4. PD (thread) pitch diameter VE visual examination aThe d

42、imensions given are the minimum space required for a screw-in cartridge valve with an allowance for using an axially fitting tool, such as a box spanner, to tighten the cartridge; if it is necessary to use a flat spanner, then adequate clearance should be provided. This is also the minimum recommend

43、ed distance between centres of two similarly sized cavities. Connectors on electrically operated valves may exceed this space dimension and allowance shall be made for fitting and removing any such connectors. bNo burrs permitted in this area; the edge shall be rounded. The cavity geometry is normal

44、ly produced with an appropriate multi-diameter form tool. Sharp edges should be avoided by rounding to a radius of 0,1 mm to 0,2 mm. cRadial groove optional. dDatum area inside ring nose. eThe port is in accordance with ISO 6149-1. Figure 2 Cavities for two-port pressure-relief valves with 5 mm to 2

45、0,5 mm maximum port diameter and with a flow direction from port 1 to port 2 BS ISO 7789:20077Table 3 Dimensions for cavities for two-port pressure-relief valves with 5 mm to 20,5 mm maximum port diameter and with a flow direction from port 1 to port 2 Dimensions in millimetres Dimension by codifica

46、tionaParameter 18-02-0-07 20-02-0-07 22-02-0-07 27-02-0-07 33-02-0-07 42-02-0-07 ThreadbM181,5 M201,5 M221,5 M272 M332 M422 D1min. 32 38 42 48 58 74 D2H8 13,5 15,5 17,5 21,5 27 36 D313,5 15,5 17,5 21,5 27 36 T1min. 14,5 14,5 15,5 19 19 19,5 T2min. 14,5 14,5 17 22 22 23 T3max. 19,5 20,5 27,5 35 38,5

47、43,5 (T4) 20 21 28 35,5 39 44 0,45 0T+22,6 23,6 30,6 38,5 42,5 47,5 T6min.c30,5 31,5 40 48 52 58 T6160T+d32 33 41,5 49,5 54 60 aCodification is in accordance with ISO 5783. bThe port is in accordance with ISO 6149-1 (relevant for dimensions and tolerances not specified in this International Standard

48、). cThis dimension is the minimum finished length required for the sealing diameter on the cartridge. dSuggested pre-machining depth to obtain appropriate diameter tolerance for T6. For some valve types, additional pilot drill dimensions may be specified by the valve manufacturer to provide clearanc

49、e for an extension to the valve and/or to allow for minimum fluid flow path in this area. Table 4 Symbol for valves entering the cavities shown in Figure 2 Description Symbol Pressure-relief valve, direct operated Pressure-relief valve, pilot operated BS ISO 7789:20078 Key 1, 2, ports NOTE The same designations are used in Table 6. PD (thread) pitch diameter VE visual examination aThe dimensions given are the minimum space required for a screw-in cartridge valve with an allowance for using an axially fitting tool, such as a box

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > BS

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1