1、 ANSI C136.17-2005 (R2010) American National Standard for Roadway and Area Lighting Equipment Enclosed Side-Mounted Luminaires for Horizontal-Burning High-Intensity Discharge Lamps Mechanical Interchangeability of Refractors ANSI C136.17-2005 (R2010) American National Standard for Roadway and Area L
2、ighting Equipment Enclosed Side-Mounted Luminaires for Horizontal-Burning High-Intensity Discharge Lamps Mechanical Interchangeability of Refractors Approved October 25, 2005 Secretariat: National Electrical Manufacturers Association Reaffirmed April 4, 2011 An American National Standard implies a c
3、onsensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether he has approved
4、 the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. The American National Standards Institute doe
5、s not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. CAUTION NOTICE: T
6、his American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of approval. Purchasers of American National Standard
7、s may receive current information on all standards by calling or writing the American National Standards Institute. Published by National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752, Rosslyn, VA 22209 Copyright 2005 by National Electrical Manufacturers Association. All ri
8、ghts including translation into other languages are reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. No part of this publication may be reproduced in any form, in a
9、n electronic retrieval system or otherwise, without the prior written permission of the publisher. Printed in the United States of America. DISCLAIMER: The standards or guidelines presented in a NEMA standards publication are considered technically sound at the time they are approved for publication
10、. They are not a substitute for a product sellers or users own judgment with respect to the particular product referenced in the standard or guideline, and NEMA does not undertake to guarantee the performance of any individual manufacturers products by virtue of this standard or guide. Thus, NEMA ex
11、pressly disclaims any responsibility for damages arising from the use, application, or reliance by others on the information contained in these standards or guidelines. ANSI C136.17-2005 (R2010) 2 CONTENTS 1 Scope 2 2 Purpose . 2 3 Physical dimensions 2 4 Materials 2 1 Scope This standard covers the
12、 dimensional features and the materials of refractors of the approximate shape shown in Figures 1 through 3, and as described in ANSI C136.14, American National Standard for Roadway and Area Lighting Equipment Enclosed Side-mounted Luminaires for Horizontal-burning High-intensity Discharge Lamps. 2
13、Purpose This standard provides: a) A description and diagrams of substitute refractors for the original refractor when replacement is necessary. b) The dimensions for a good fit for the refractor at the points of contact, the points of attachment, or both, to the reflector or the housing, or to both
14、 the reflector and the housing. c) Requirements for light distribution acceptable to the user, but not necessarily equal to the original optical system. NOTE The optics package consisting of the lamp, the reflector, and the refractor configuration is unique to the individual luminaire. Replacement o
15、f a single luminaire component will not guarantee the same optical performance. The requirements and figures of this standard will help keep the number of refractors needed on service vehicles to a minimum. 3 Physical dimensions Figures 1 through 3 show the refractors points of contact, points of at
16、tachment, or both, to the reflector, the housing, or both. The dimensions given in these figures are for interchangeability, and other variants satisfying non-dimensioned provisions may be capable of otherwise equivalent performance. 4 Materials Refractors may be made of heat-resistant glass, polyca
17、rbonate, acrylics, or other suitable materials as specified by the user. ANSI C136.17-2005 (R2010) 3 NOTE-All dimensions are in mill i m e t e rs (i n c h e s )Tol er anc e( U nles s othe r w ise m arked)No. of decim als Tol er anc e23 0.76mm (0.03 I n.) 0.38mm (0.015 In.)Figure 1 Flange dimensions
18、for refractors for small horizontal-burning HID luminaires ANSI C136.17-2005 (R2010) 4 NO TE -A ll dim ensions are in m illime te rs (in c he s ).T olerance(U nles s otherw ise marked)No. of decim als T olerance230.76m m ( 0.03 In.) 0. 38mm ( 0.0 15 In.)Figure 2A Flange dimensions for refractors for
19、 medium horizontal-burning HID luminaires ANSI C136.17-2005 (R2010) 5 NO T E -A ll d im en si on s ar e in m il li m eter s ( in ch es ) .Tol era nc e(U nle s s othe rw is e m a rke d)N o. of dec im a ls Tol era nc e230.76m m (0.03 In.) 0.38m m (0.015 In.)Figure 2B Flange dimensions for refractors for medium horizontal-burning HID luminaires (continued) ANSI C136.17-2005 (R2010) 6 Figure 3 Flange dimensions for refractors for large horizontal-burning HID luminaires